You are on page 1of 2

Hydraulic Design of Main Spillway

1 Design Data

Design Flood 4700 cumec


FRL 764 m
MWL 764 m
Spilway Crest Level, CL 730 m
Width of Gate Openning, W 8 m
Bottom of Breast Wall 742 m
Height of Gate Openning,D 12 m
NO. of Opennings 4 no.
NO. of Piers, N 5 no.
Discharge Coefficient of Design Head, C 0.71

2 design as per is 6934


Case 1 When All Gates Operative
Head From Centreline of Openning, Ha 28
Total Openning of Spillway 32
Discharge Coefficient For Design Head, C 0.71
Spillway Capacity Q, CA(2gh)^0.5 6390.25355 cumec

3 Case 2 When All Gates Operative


Toatal No of Operative Gates 3
No of Piers 4
Head From Centreline of Openning, Ha 28
Total Openning of Spillway 24
Discharge Coefficient For Design Head, C 0.71
Spillway Capacity Q, CA(2gh)^0.5 4792.690163 cumec

4
Summary of Result
Method Discharge(cumec)
When All Gates Operative When All Gates Operative
Reservoir Level 764 764
Desined Value 6390.25355 6390.25355
When All Gates Operative