Fault code: MID 185 - PSID 3 - FMI8


General information on the fault code:
MID185 G051 - Air production management ECU

PSID3 Regeneration electrovalve

FMI-8 Abnormal frequency


Appliance(s) implicated:

Appliance(s) implicated:

G051 Air production management ECU

Condition(s) and reason(s) for saving of fault code:

Appliance G051 is submitted to electromagnetic interference.


The communication bus CAN SAE J1939 is faulty.
The communication bus SAE J1587 is faulty.
The G051 equipment is defective.

Perceptible symptoms or "customer complaint" due to fault:

D107 Air management fault warning light

The warning light D048 comes on (D048: "STOP" warning light ; D049: "SERVICE" warning light).

The following message is displayed:


IMMEDIATE STOP

Recording of the fault code by the ECU G051.


There is no regeneration of the air dryer cartridge.

The warning light D048 comes on (D048: "STOP" warning light ; D049: "SERVICE" warning light).

The following message is displayed:

IMMEDIATE STOP

Recording of the fault code by the ECU G051.

There is no regeneration of the air dryer cartridge.

https://secureweb.renault-trucks.com/K58WEBMR/web/controller (1 of 3)1/24/2012 10:58:04 AM


https://secureweb.renault-trucks.com/K58WEBMR/web/controller

Troubleshooting and repair method:

In order not to damage the equipment, the repair steps should be carried out in the correct order.

IN NO CIRCUMSTANCE SHOULD THE "AIR PRODUCT MANAGEMENT" SYSTEM BE DISASSEMBLED.

Only the cartridge and the exhaust pipe can be subjected to maintenance.

General checks:

Check the general state of the function:

● The wiring harnesses and the fluids routing pipes are sound.
● The connectors are neither oxidized nor physically damaged.
● The connecting arrangement is not damaged.
● The connectors are properly plugged into their equipment.

Diagnostics using the RENAULT TRUCKS test tool:

Using the RENAULT TRUCKS test tool, perform the operation 5630-08-03-01.

Advanced control and monitoring:

Measurements and diagnostics on the module G051 :

Illustration of the module G051 Location

https://secureweb.renault-trucks.com/K58WEBMR/web/controller (2 of 3)1/24/2012 10:58:04 AM


https://secureweb.renault-trucks.com/K58WEBMR/web/controller

Key: in the illustration above, the unit G051 is identified by item "A".

The location (see illustration above) is given as an indication only, for more precision, refer to the appropriate vehicle repair manual.

Preparation for tests and measurements:

Turn the ignition key to the "stop" position. Turn the master switch to the "OFF" position. Turn the master switch to the "ON" position. Erase the fault code then restart the engine. Check whether the code
is again recorded. If so, turn the ignition key to the "stop" position, turn the master switch back to the "OFF" position and wit for 30 seconds before undertaking any troubleshooting.

Tests and measurements:


Check that the appliance G051 is not submitted to electromagnetic disturbance.
If the cause of the problem has not been found, move on to the next check.
Check the state of the wiring and connecting arrangement of CAN SAE J1939.
If the cause of the problem has not been found, move on to the next check.
Check the state of the wiring and connecting arrangement of SAE J1587.
If the fault is still present, replace the G051 equipment.

https://secureweb.renault-trucks.com/K58WEBMR/web/controller (3 of 3)1/24/2012 10:58:04 AM