4.3.17.1 GENERAL
The Coal Fired Power Plant and its accessories furnished under this
contract shall be designed to perform satisfactorily burning coal
(bituminous, sub bituminous or lignite) and light oil fuel or the range of
values indicated.
Fuel analyses specified herein, are preliminary and provided to the Bidder
for his reference.
In case the Bidder requires any other item to be covered by the fuel and
analysis compared to those listed below, the Bidder must state that in the
Proposal.
Range
Parameter Typical
Minimum Maximum
Proximate Analysis (% as received)
Total Moisture 25 38 35
Inherent Moisture 13.8 25 18
Ash 3.3 6 5
Volatile Matter 27.9 40 35
Fixed Carbon 23 41 30
Specific Energy (as received)
High Heating Value (kCal/kg) 3900 4700 4200
Ultimate Analysis (% dry ash free)
Carbon 65 80 68.57
Hydrogen 3 5.9 5.16
Nitrogen 0.54 1.2 1.18
Oxygen 12 30 24.76
Sulphur 0.25 0.50 0.40
Ash Analysis (%)
2
SiO2 60 16
3
AI2O3 52 9
4.7
Fe2O3 52.5 36
0.02
TiO2 4.1 0.48
0.2
Mn3O4 8.8 4
0.8
CaO 27.7 19.7
0.02
MgO 32.6 10
0.05
Na2O 4.12 0.18
0.1
K2O 2.4 1.3
0.03
P2O5 0.8 0.51
0.2
SO3 24.6 2.83
Ash Fusion Temperature (0C) Reducing Reducing Reducing
I.D.T. (deformation) 1120 1150
S.T. (softening) 1200
H.T. (hemispherical) 1250
F.T. (fluid) 1300
The Minimum and Maximum Range of Design Coal shall be used to design the Boiler.
The Typical Design Coal shall be used for Performance Test Guarantee purposes.