You are on page 1of 2

tersaco.

ch

Santhia 1200
Fully automated
clinical chemistry analyzer
santhia 1200
Fully automated clinical chemistry analyzer

Type Fully automated clinical chemistry analyzer


General chemistry as photometric assay
Usage
lmmunology as photometric assay (Latex reagents available)
Assay type End point, 2 point end, Rate, 2 point rate and electrolytes
Throughput 800 tests per hour (Up to 1200 tests per hour with optional ISE module)
Ten minutes after applying sample for one reagent assay
lncubation time
Five minutes after applying second reagent for two reagents assay
Sample type Serum, Plasma and Urine
Type: Removable tray with sample tube holder on a turntable
Sample input
Capacity: Up to 94 samples (handling of STAT available)
system
QC sample and Calibrator: 10 positions on designated inner tray
Type: Micro-pipette with liquid level detector and clot detector
Sampling pipette
Rinsing: lnside and outside with purified water
Type: Micro syringe
Sampling pump
Volume: 0.5 to 25.0 μl (increment by 0.1 μl)
Type: Removable tray with reagent bottle holder on a turntable
Capacity: 100 reagent positions on a tray (Fifty 70 ml and fifty 20 ml bottle positions)
Reagent system
lnventory: Calculation of remaining reagent volume available
Cooling: Cooling with Peltier element (8 to 15 degrees Celsius)
Numbers of pipettors: Two
Type: Micro-pipette with liquid level detector
Reagent pipette
Rinsing: lnside and outside with purified water
Other function: Detection of remaining reagent volume available
Type: Micro syringe
Reagent pump R1 Volume: 20 to 250 μl (increment by 1 μl)
R2Volume: 5 to 180 μl (increment by 1 μl)
Number of cuvettes: 153 cuvettes on reaction line
Type: Semi-disposable cuvette with onboard washing system
Cuvette system Material: Resin
Volume for measurement: Minimum 50 μl
Maximum volume: 250 μl in total
Type: Direct heating system
Reaction system
Temperature: 37.0 degrees Celsius (+/- 0.2)
Method: Direct measurement of absorbance in cuvette
Bi-chromatic or Mono-chromatic
Detector
Wavelength: 340, 380, 415, 450, 478, 510, 546, 570, 600, 660, 700, 750, 800
Light source: Halogen tungsten lamp
Stirring system Type: Stick type rotating stirrer
Dimensions 1300 mm (W) x 850 mm (D) x 1150 mm (H) (Analyzer only)
Option On board ISE module, Glass cuvette