STRUCTURAL DESIGN

for the
PROP. SIX (6) – STOREY R.C BUILDING
A. LOADS:
ROOF DECK:

FLOOR COVERING -------------------------------------- 50 Pa


CONCRETE FRAME ------------------------------------- 5,917
CEILING---------------------------------------------------- 250
MECHANICAL & ELECTRICAL-------------------------- 500
MISCELLANEOUS----------------------------------------- 220
--------------------------
DEAD LOAD = 6,937 Pa
FLOORS: 6TH/5TH 4TH 3RD/2ND
FLOOR COVERING 50 Pa 50 50
CONCRETE COVER 6,109 6,510 6,547
CEILING 250 250 250
PORTION 1,000 1,000 1,000
MECHANICAL & 500 500 500
ELECTRICAL
MISCELLANEOUS 200 220 220
DEAD LOAD 8,129 Pa 8,530 Pa 8,567 Pa

EXTERIOR WALL ------------------------------ 200


LIVE LOAD (OFFICE SPACE) ------------------ 2,400 Pa
PORTION (LIVE LOAD) ------------------------ 960
ELEVATOR (LIVE LOAD) ----------------------- 1,000
ELSCALATOR (LIVE LOAD) -------------------- 1,000
--------------------
TOTAL LIVE LOAD = 5,360 Pa or 5,400 Pa
 NOTE FLOOR LOADS:

1. IT WILL BE ASSUMED THAT THE BASIC LIVE LOAD FOR THE


ESCALATOR IS 2.40 Kpa (50psf). AN ADDITIOMAL ELEVATION &
ESCALATOR LIVE LOADS OF 0.96 Kpa (42psf): AND A PARTION LIVE
LOAD OF 0.96 Kpa (20psf) ARE TO BE SPECIFIED BECAUSE THE
LOCATION & ALSO THE CORRIDOR ARE NOT KNOWN: HENCE WILL BE
SUBJECTED TO CHANGE, THE ENTIRE FLOOR WILL BE DESIGNED FOR
A LIVE LOAD OF 5.36 Kpa or SAY, 5.40 Kpa (113psf.)

2. THERE WILL BE NO REDUCTION FOR LIVE LOADS GREATER THAN 4.80


Kpa (REFER TO SEC. 205 – 5 on p. 2 – 15 OF NSCP 2015 ED.)

LIVE LOAD ≤ 4.8 Kpa


B. MATERIALS

CONCRETE: f ’c = 27.5 Mpa


Ec = 4,700 √𝑓′𝑐 = 25 𝑥 103 𝑀𝑝𝑎
STEEL: fy = 410 Mpa

C. WIND LOAD ( ZONE – II ) :


P = qGCP – qi (GCPi)
@ ZONE II : V = 200 Kph

D. SEISMIC LOAD (ZONE – 4 )


𝐶𝑣𝐼
𝑉= 𝑊
𝑅𝑇

@ ZONE – 4 : ≠ 0.40 : INTENSITY - VIII