4. Which of the following is not 9. The advantage of D.C system
the transmission voltage in over A.C system is:
india? (a) Improved line regulation
(a) 66KV (b) No skin effect
(b) 132KV (c) No charging currents
(c) 275KV (d) All of above
(d) 400KV
Ans b
Ans c
10. For high voltage
5. Which of the following is application, the insulator
usually generating voltage in used are of:
india (a) Suspension type
(a) 11KV (b) Pin type
(b) 22KV (c) Strain type
(c) 33KV (d) None of these
(d) 66KV
Ans a
Ans d
11. The top most wire in a
Page 1
OBJECTIVE ELECTRICAL ENGINEERING TRANSMISSION AND DISTRIBUTION
Page 2
OBJECTIVE ELECTRICAL ENGINEERING TRANSMISSION AND DISTRIBUTION
Ans d
Ans c
24. Rise of temperature of
transmission line 29. From the consideration of
(a) Increases the stress and cost and safety, the outdoor
decrease the length substation are installed for
(b) Decreases the stress and voltage exceeding:
increase the length (a) 6.6KV
(c) Increase the stress and (b) 11KV
increase the length (c) 33KV
(d) Decrease the stress and (d) 66KV
decrease the length
Ans c
Ans b
30. ACSR is used for
25. Lightning arrestier transmission of power in
should be located: preference to copper
(a) Away from the circuit conductors because:
breaker (a) It is lighter
(b) Near the circuit breaker (b) It is more economical
(c) Away from the transformer (c) It has higher current
(d) Near the transformer carrying capacity
(d) It can stand higher surge
voltage
Ans d
Page 3
OBJECTIVE ELECTRICAL ENGINEERING TRANSMISSION AND DISTRIBUTION
(a) Silver
(b) Aluminium Ans b
(c) Copper
(d) Zinc 46. If a transmission line
voltage is increased in times,
the size of the conductor
Ans would be
(a) Increased n2 times
42. For 66 KV overhead (b) Reduced 1/n times
transmission line. The (c) Reduced 1/n2 times
clearance along any street (d) Increased n times
above ground shall not be less
than:
(a) 5.791 m (19 feet) Ans c
(b) 5.486 m (18 feet)
(c) 5.182 m (17 feet) 47. Earthing is necessary to
(d) 6.096 m (20 feet) give protection against:
(a) Overloading
(b) Voltage fluctuation
Ans d (c) High temperature of the
conductor
43. In the case of a neutral (d) Danger of electric shock
wire:
(a) Its potential is zero at all
points Ans d
(b) It acts as a return
conductor 48. In an overloading
(c) It may carry current only in transmission line, the tension
case of earth fault on the conductor during summer
(d) It is connected to earth at season is:
an intermediate point (a) More
(b) Equal to winter summer
(c) Less
Ans b (d) None of the above
44. The device which connects
a conduct or to the earth to Ans
dischange the charge on the
conductor to the earth is 49. Conductor used in high
called: tension transmission lines,
(a) H.R.C fuse are stranded because :
(b) Circuit breaker (a) It is easy to handle
(c) Insulator (b) It is cheap
(d) Earthing switch (c) It increases tensile
strength
(d) It increases conductivity
Ans d
45. If a transmission line Ans a
sag is kept too low, then :
(a) The highest of the towers 50. The main reason is using
will be more high voltage for long distance
(b) Tension will be more on power is to:
overhead conductor (a) Reduce the travel of
(c) The height of the towers transmission
will be less (b) Reduce the transmission
(d) More conductor material is losses
needed (c) None of the above
Page 5
OBJECTIVE ELECTRICAL ENGINEERING TRANSMISSION AND DISTRIBUTION
Page 6
OBJECTIVE ELECTRICAL ENGINEERING TRANSMISSION AND DISTRIBUTION
Ans a Ans b
61. No. of L.T bushings on a 66. Where the lightening
11/0.4 KV distribution arrestors installed on a pole
transformer are: mounted distribution sub-
(a) 3 station
(b) 4 (a) On the top of h pole
(c) 5 (b) Near the HT fuse unit
(d) 6 (c) Away from the transformer
(d) None of the above
Ans b
Ans b
62. A sub-station is earthed
at minimum of 67. Power factor of a factory
(a) 3 places can be improved by the factory
(b) 2 places by installing:
(c) 1 places (a) Transformer near his factory
(d) 4 places (b) Installing power factor
meter
(c) Shunt capacitors near load
Ans a (d) By generating more KVAR at
the power house
63. Gang operating switched
called G.O switch is used for Ans c
switching on and off the:
(a) 33 KV 68. Which of the following is
(b) 11 KV the protective device against
(c) LT KV lightning over voltage?
(d) EHV line (a) Rod gap
(b) Surge absorbers
(c) Horn gap
Ans b (d) All of the above
64. In our house we have Ans d
normally 230V, AC 50 HZ supply
and there are two wire 69. Transmission efficiency
connected to supply system increases as
these wire are: (a) Voltage and P.F both
(a) One neutral and one earth increase
(b) One neutral and one phase (b) Voltage and P.F both
(c) One phase and one wire decrease
connected to earth (c) Voltage increases but P.F
(d) Two phase of A.C decrease
distribution system (d) Voltage decrease but P.F
increase
Ans b Ans a
65. Number of lighting 70. Wooden poles for
arrestors to be installed on a supporting transmission lines
pole mounted distribution sub- are used on voltage up to
Page 7
OBJECTIVE ELECTRICAL ENGINEERING TRANSMISSION AND DISTRIBUTION
Page 8
OBJECTIVE ELECTRICAL ENGINEERING TRANSMISSION AND DISTRIBUTION
Ans d Ans b
85. Current rating is not 90. The effect of wind
necessary in case of pressure is more predomination
(a) Isolators on
(b) Circuit breakers (a) Supporting towers
(c) Load breaker switches (b) Neutral wires
(d) All of the above (c) Transmission lines
(d) Insulators
Ans a
Ans a
86. Which of the following
equipment is not installed in 91. Which of the following
a sub-station? can be used for bus-bar?
(a) Shunt reactions (a) Tubes
(b) Exciters (b) Rods
(c) Voltage transformers (c) Bars
Page 9
OBJECTIVE ELECTRICAL ENGINEERING TRANSMISSION AND DISTRIBUTION
Page 11
OBJECTIVE ELECTRICAL ENGINEERING TRANSMISSION AND DISTRIBUTION
Ans c Ans a
113. The current carrying 118. 63 KVA distribution
capacity of a conductor: transformer installed for
(a) Decreases with rise in supply a village. transformer
temperature takes how much current in
(b) Increases with rise in ampereses at 11 Kv side and
temperature 0.4 KV LT side
(c) It is not affected (a) 1.31 A/34.8 A
(b) 2.62 A/69.6 A
(c) 3.30 A/88.0 A
Ans a (d) 5.25 A/139.1 A
114. Copper conductor is
always tinned in: Ans c
(a) V.I.R cables
(b) P.V.C cables 119. 200 KVA distribution
(c) Paper insulated cables transformer installed for
(d) None of the above supply a city. Transformer
takes how much current in
ampereses at 11 KV HT side and
Ans a 0.4 KV
(a) 5.25 A/139.1 A
115. As per Indian electricity
(b) 10.50 A/278.2 A
rules the maximum difference
(c) 15.75 A/417.4 A
between declared voltage and
(d) 26.25 A/695.6 A
actual voltage at consumer
permises should be:
(a) +-6% Ans b
(b) +-5%
(c) +-8% 120. Load shedding is possible
(d) +-10% through
(a) Switching off the loads
(b) Frequency reduction
Ans a (c) Voltage reduction
(d) Any of the above
116. The commonly used phase
sequence is:
(a) RYB Ans d
(b) BRY
(c) YBR
(d) Any of the these
Ans d