Tetra Pak® A3/Speed 0300

iLine

Technical Data Tetra Pak A3/Speed 0300

CAPACITY FILLING MACHINE NOISE


Tetra Pak A3/Speed Tetra Pak A3/Speed Tetra Pak A3/Speed
Packages per hour (selectable capacity): Portion Family Family PT
Max. emission sound
TBA 125 S: 16.000-20.000-24.000 p/h
TBA 200 B: 16.000-20.000-24.000 p/h pressure level at the
TBA 200 M: 16.000-20.000-24.000 p/h operator position (Lpa)*: 78,5 dB (A) 79,5 dB (A) 79,5 dB (A)
TBA 200 S: 16.000-20.000-24.000 p/h
TBA 250 B: 16.000-20.000-24.000 p/h Measured A-weighted
TBA 250 S: 16.000-20.000-24.000 p/h Sound Power Level (Lwa)**: 98 dB (A) 98 dB (A) 99 dB (A)
TBA 1000 Sq PLH: 9.000-12.000-15.000 p/h *Determined according to ISO 11204
TBA 1000 S PT: 9.000-12.000-15.000 p/h **Determined according to ISO 3744
TBA 1000 B: 9.000-12.000-15.000 p/h
TBA 1000 Sq PT: 9.000-12.000-15.000 p/h UTILITIES
Note: No viscous and semi-viscous product can be packed Electrical power
Voltage, V: 400/230 ± 10%
PRODUCT SUPPLY Frequency, Hz: 50/60 ± 2%
Product pipe size (portion packs) 2”- 3” Recommended main fuse, A 160 A
Product pipe size (family packs) 3” Consumption: Tetra Pak A3/Speed Tetra Pak A3/Speed Tetra Pak A3/Speed
Product temperature range C° (F°) 10-30 (50-86) Portion Family Family PT
Tube sealing (kW): 6,2 6,6 6,9
Note 1: higher product temperatures are possible with reduced capacity Preheating (kW): 32,9 34,7 35,9
Note 2: processing capacity +20%
Spraying (kW): 28,2 30,5 28,8
Characteristic Value Notes Drying (kW): 25,8 26,3 27,6
Production start (kW): 58,5 66,3 70,5
150 - 250 kPa Production stable (kW): 35,9 50,1 51,0
Supply pressure Measured near the
(1.5 - 2.5 bar)
accepted range product valve. Compressed air Tetra Pak A3/Speed Tetra Pak A3/Speed Tetra Pak A3/Speed
[21.7 - 36.2 psi]
Portion Family Family PT
±50 kPa Variation within the
Max. pressure Min. supply pressure, kPA (bar): 6,0 6,0 6,0
(±0.5 bar) supply pressure
variation Consumption during
[±7.25 psi] accepted range.
production (Nl/min): 835±17 1010±20 2020±41
The pressure shock Peak consumption
100 kPa duration is a (Nl/min): 990±20 1900±38 2120±43
Max. pressure
(1 bar) maximum of
shock
[14.5 psi] 1 second (within Water supply, cold
the pressure range). Connection pressure, kPa (bar): 300-450 (3-4,5)
Max inlet temperature, °C (°F): 14-20 (57-68)
Maximum fluctuation
Filling 10 - 30°C Water during production: Tetra Pak A3/Speed Tetra Pak A3/Speed Tetra Pak A3/Speed
during production
temperature (50 to 86°F) Portion Family Family PT
±5°C.
Consumption (l/min): 15,6±0,7 22,7±1,0 24,3±1,0
Feed capacity at the
first start and for
Overcapacity 20% Steam
bucket refilling,
see note below. Min. connection pressure, kPA (bar) : 2,0
Product must leave Temperature °C (°F): >130 (>266)
Particles Absent no hard residue on a Consumption (kg/h): 2,4 during production
+ 7,0 for ICU Cycle
600 μm mesh.
Measured as fibre Hydrogen peroxide (H2O2)
Citrus fibres <5% residue on a 600 μm Concentration 35%
mesh. Consumption, I/h: 3,0 to 5,0
pH 2.5 - 8
Grease
Note! With multiple installations it is fundamental that the correct Consumption, I/h: FP 240 cc/1.000.000 packs
overcapacity is defined: please refer to the Installation Manual PP 160 cc/1.200.000 packs
n. IM-3044491-0104 for guidance.
Technical Data Tetra Pak A3/Speed 0300

CLEANING
ICU (Integrated Cleaning Unit) 3
359
Cold water supply, I/h Min 3000
Flow, It/h Min 8000
Consumptions:
Cold water, I/cycle 350
Steam, kg/h 7 2346

EXTERNAL CLEANING

6052 (at open lid)


Water supply, kPa (bar): 300-450 (3-4,5)
Water max inlet temperature,°C (°F): 20 to 25 (68 to 77)
Detergent pH 10-12 67
15
Consumptions: 75
06 18
02 10
11
Water, I/cycle 250
Detergent, I/cycle 1,2

WORKING ENVIRONMENT TEMPERATURE*


Min temperature °C (°F): 5 (41)
Max temperature °C (°F): 50 (122) Dimensions:
15-30 (59-86) External measurements (mm):
Recommended temperature °C (°F)
- Tetra Pak A3/Speed (without PullTab): 7506
*(temperature measured at the EC Cooler air inlet area)
- Tetra Pak A3/Speed (with PullTab): 9328
OPTIONAL EQUIPMENT/OPTIONAL KIT
Packaging for shipping boxes:
PullTab - available as OE
External measurements (mm): L D H
Stair RH - available as OE
Headspace by Injection - available as OE and OK - Tetra Pak A3/Speed (without PullTab).... 4800 2100 2870
3300 2100 2870
. 4200 2400 2950
INSTALLATION DRAWING NO.
- Tetra Pak A3/Speed (with PullTab)......... 4800 2100 2870
Tetra Pak A3/Speed: 648576-3 3300 2100 2870
Tetra Pak A3/Speed with PullTab: 648576-4 4200 2400 2950

CERTIFICATIONS:
FDA filed
CE
3A

www.tetrapak.com
We reserve the right to introduce design modifications without prior notice,
Tetra Pak, , protects what’s good are trademarks belonging to the Tetra Pak Group.

Tetra Pak Packaging Solutions / ADCode 0710S en. Date 07/2010