Professional Documents
Culture Documents
Cooler Calculation
Cooler Calculation
Operating
48840000 kcal/hr Fan Flux Area Fan flow
kg/m2/min m2 m3/hr
48.84 Mkcal/hr 38761 8.57 FN1 129 11.52/2 38763
38761 8.57 FN2 129 11.52/2 38763
56.7907 MW 89406 19.78 FN3 90 18.98 89410
54774 12.12 FN4 81 12.92 54777
204 GJ/hr 55819 12.35 FN5 69 15.49 55822
58604 12.96 FN6 62 18.07 58607
% utilisation 58.2 60304 13.34 FN7 56 20.66 60307
55613 12.30 FN8 50 21.17 55616
kg/kg clinker
Nm3/kg Clinker
Nm3/kg Clinker
11.09.19
Pressure drop Current
PH fan 850
Top cyc 765
Cyc-II 624
Cyc-III 570
Cyc-IV 475
Cyc-V 355
Cyc-VI 220
Cal
Kiln I/L 75
TAD
Hood -4