1. use in hot water storage tank, controlled B. 1 1/4"


outlet/pipe use to discharge water detritus C. 3"
and steam, one type of relief vent. D. 2"
A. BLOW ON 14. TRAP SEAL FOR FLOOR DRAIN
B. BLOW OFF A. 1 1/2"
C. HOT VALVE B. 1 1/4"
D. PRESSURE VALVE C. 3"
2. TRAP SEALS FOR WATER CLOSETS D. 2"
A. 1 1/4" 15. TRAP SEAL FOR BIDET
B. 1 1/2" A. 1 1/2"
C. 3" B. 1 1/4"
D. 2" C. 3"
3. TRAP SEALS FOR WASH BASIN LAVATORIES D. 2"
A. 1 1/4" 16. TRAP SEAL FOR BATH TUB
B. 1 1/2" A. 1 1/2"
C. 3" B. 1 1/4"
D. 2" C. 3"
4. TRAP SEALS FOR URINAL THROUGH D. 2"
A. 1 1/2" 17. TRAP SEAL FOR LAUNDRY TRAYS
B. 1 1/4" A. 1 1/2"
C. 3" B. 1 1/4"
D. 2" C. 3"
5. TRAP SEALS FOR URINAL STALL D. 2"
A. 1 1/2" 18. TRAP SEAL FOR FOUNTAIN CUP SIDERS
B. 1 1/4" A. 1 1/2"
C. 3" B. 1 1/4"
D. 2" C. 3"
6. TRAP SEALS FOR URINAL PEDESTAL D. 2"
A. 1 1/2" 19. TRAP SEAL FOR FOOT BATH SITZ
B. 1 1/4" A. 1 1/2"
C. 3" B. 1 1/4"
D. 2" C. 3"
7. TRAP SEALS FOR URINAL LIP D. 2"
A. 1 1/2" 20. TRAP SEAL FOR FOOT BATH SHOWER STALL
B. 1 1/4" A. 1 1/2"
C. 3" B. 1 1/4"
D. 2" C. 3"
8. TRAP SEALS FOR SLOPS SINKS (ORDINARY) D. 2"
A. 1 1/2" 21. TRAP SEAL FOR FOOT BATH
B. 1 1/4" A. 1 1/2"
C. 3" B. 1 1/4"
D. 2" C. 3"
9. TRAP SEALS FOR SLOPS SINKS (COMBINE D. 2"
TRAP) 22. TRAP SEAL FOR DRINKING FOUNTAIN
A. 1 1/2" A. 1 1/2"
B. 1 1/4" B. 1 1/4"
C. 3" C. 3"
D. 2" D. 2"
10. TRAP SEALS FOR SINKS (SMALL PANTRY OR 23. TRAP SEAL FOR COMBINATION FIXTURE
BAR) A. 1 1/2"
A. 1 1/2" B. 1 1/4"
B. 1 1/4" C. 3"
C. 3" D. 2"
D. 2" 24. THERE ARE DIFFERENT TYPES OF BIDET, WHICH
11. TRAP SEALS FOR SINKS (KITCHEN or IS NOT THE FOLLOWING
RESIDENCE) A. STALL
A. 1 1/2" B. STAND
B. 1 1/4" C. RECESSED
C. 3" D. LATTE
D. 2" 25. that portion of a pipe which for a short
12. TRAP SEALS FOR SINKS (hotel or public) distance, is sufficiently enlarged to receive
A. 1 1/2" the end of another pipe of the same
B. 1 1/4" diameter for the purpose of making a joint.
C. 3" A. BELL OR HUB
D. 2" B. ELBOW
13. TRAP SEALS FOR SINKS (DISH WASHER) C. ANGLE PIPE
A. 1 1/2" D. NONE OF THE ABOVE
1
PLUMBING 4A
26. known today as hose bib (H B), part of ROAD AND UNDER THE ROAD ON WIDE
water line and is a faucet found in service ROAD
area and gardens. C. AT THE CENTER OF THE ROAD
A. BIBB D. NEAR THE CURB
B. FAUCET 37. TEFLON, A WHITE, SOFT, WAXY, AND NON
C. SERVICE PIPE ADHESIVE POLYMER IS USED AS A LEAK
D. NONE OF THE ABOVE PREVENTION MATERIAL FOR PIPES
27. For W C without water storage tank, a cup PARTICULARLY GALVANIZED IRON PIPES. IT IS
like shell, ball in cup-like shell that allow PLACED BETWEEN THE THREADED PIPE END
movement AND FITTING, WHAT IS THE CHEMICAL NAME
A. JOINT OF TEFLON?
B. ANGLE JOINT A. TRIFLOURORTHANE
C. BALL JOINT B. POLYETHYLENE
D. COCK JOINT C. TETRAFLOUROETHYLENE
28. Faucet opened and closed by a ball D. PENTAFLOUROCARBON
floating on the water, also called ball cock 38. AN ENGINEERED MATERAIL CREATED
valve. THROUGH A PATENTED PROCEDURE THAT
A. BALL COCK BONDS GLOSSY PORCELAIN ENAMELED
B. BALL VALVE METAL TO A STRUCTURAL COMPOSITE
C. CHECK VALVE THROUGH AN INJECTION MOULDING
D. COCK PROCESS, USED PARTICULARLY IN
29. Air pressure in drainage pipe greater than MANUFACTURING BATHUBS. WHAT IS THE
atmospheric pressure. PATENTED MATERIAL USED IN THE MARKET
A. BACK PRESSURE TODAY?
B. BACK FLOW A. XPELOR
C. BACK SIPHONAGE B. DACRON
D. BEHIND PRESSURE C. LUCITE
30. A vertical pipe FOR WATER SUPPLY D. AMERCAST
A. RISER 39. IN A TYPICAL GREASE TRAP, WHAT SHOULD
B. STACK BE THE CORRECT ARRANGEMENT OF ITS
C. BRANCH INLET AND OUTLET IN ITS ELEVATION
D. SERVICE PIPE A. THE INLET SHOULD BE HIGHER THAN THE
31. A vertical pipe FOR DRAINAGE OUTLET
A. RISER B. THE OUTLET SHOULD BE HIGHER THAN THE
B. STACK INLET
C. BRANCH C. BOTH INLET AND OUTLET SHOULD BE AT
D. SERVICE PIPE THE SAME ELEVATION SPECIFICALLY AT
32. A tool used for straightening or expanding THE UPPER SECTION OF THE TRAP
lead pipe. D. ANY ELEVATION WILL DO
A. LEAD EXPANSION 40. A STANDARD PIPING MATERIAL USED BY THE
B. BENDING PIN LOCAL WATER UTILITY COMPANY TO
C. BENDING JOINT CONNECT THE WATER SERVICE PIPE OF ANY
D. PIN ESTABLISHMENT TO THE WATER MAIN. WHAT
33. A length of soil or waste stack that branch IS THIS PLASTIC PIPING MATERIAL?
into the main at storey height, one branch A. POLYVINYL CHLORIDE (PVC)
not less than 8 feet B. UNPLASTICIZED POLYVINYL CHLORIDE
A. BATTERY (PVC)
B. BRANCH C. ACYLONITRILE BUTADINE STYRENE (ABS)
C. BRANCH INTERVAL D. POLYETHYLENE (PE)
D. NONE OF THE ABOVE 41. WHEN DESIGNING A SEPTIC TANK, WHICH OF
34. a plumbing fixture use to wash the genitals, THE FOLLOWING PRACTICES IS NOT
also called a sitz bath (tool bath) ACCEPTABLE IN SO FAR AS STANDARD
A. BIDET TRADE PRACTICE AND CODE REQUIREMENT
B. LAVATORY IS CONCERENED
C. WATER CLOSET A. A VENT IS NECESSARY
D. BIBB B. INLET PIPE CONNECTED AT THE
35. IN STORM DRAIN SYSTEM, IT IS USED TO LEACHING CHAMBER
PREVENT AGGREGATES, DEBRIS AND OTHER C. NO AIR SPACE BETWEEN UNDERSIDE OF
UNWANTED OBJECTS FROM ENTERING THE SLAB AND SCUM LINE
DRAINAGE SYSTEM D. ALL OF THESE
A. TRAP
B. STRAINER
C. CATCH BASIN
D. FLOOR DRAIN
36. WHERE ARE STORM SEWER USUALLY PLACED
A. AT THE GATE
B. UNDER THE SIDE WALK ON NARROW