Simulation variant :
Simulation parameters
Holtekamp 1
Simulation date
Simulation for the
System type
13/02/20 18h13
1st year of operation
Tables on a building
Collector Plane Orientation Tilt 10° Azimuth 33°
Sheds configuration Nb. of sheds 2222 Identical arrays
Sheds spacing 0.80 m Collector width 3.96 m
Shading limit angle Limit profile angle 167.5° Ground cov. Ratio (GCR) 495.1 %
PVsyst TRIAL
Horizon Free Horizon
Near Shadings Linear shadings
User's needs : Unlimited load (grid)
PV Array Characteristics
PV module Si-poly Model CS6U - 325P
Original PVsyst database Manufacturer Canadian Solar Inc.
Number of PV modules In series 18 modules In parallel 2222 strings
Total number of PV modules Nb. modules 39996 Unit Nom. Power 325 Wp
Array global power Nominal (STC) 12999 kWp At operating cond. 11657 kWp (50°C)
Array operating characteristics (50°C) U mpp 595 V I mpp 19576 A
Total area Module area 77765 m² Cell area 70092 m²
PVsyst TRIAL
Inverter
Original PVsyst database
Characteristics
Inverter pack
Model
Manufacturer
Operating Voltage
Nb. of inverters
SG2000
Sungrow
460-850 V
5 units
Unit Nom. Power
Total Power
Pnom ratio
2000 kWac
10000 kWac
1.30
PVsyst TRIAL
Module Quality Loss Loss Fraction 0.0 %
Module Mismatch Losses Loss Fraction 1.5 % at MPP
Strings Mismatch loss Loss Fraction 0.10 %
Module average degradation Year no 1 Loss factor 0.7 %/year
Mismatch due to degradation Imp RMS dispersion 0.4 %/year Vmp RMS dispersion 0.4 %/year
PVsyst TRIAL
Unavailability of the system 1.8 days, 3 periods Time fraction 0.5 %
Auxiliaries loss constant (fans) 20.0 kW ... from Power thresh. 0.0 kW
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst Evaluation mode
PVSYST V6.81 13/02/20 Page 3/7
PVsyst TRIAL
PV modules Model CS6U - 325P Pnom 325 Wp
PV Array Nb. of modules 39996 Pnom total 12999 kWp
Inverter Model SG2000 Pnom 2000 kW ac
Inverter pack Nb. of units 5.0 Pnom total 10000 kW ac
User's needs Unlimited load (grid)
PVsyst TRIAL
PVsyst TRIAL 90
5
Shading loss: 1 %
Shading loss: 5 %
Shading loss: 10 %
Iso-shadings diagram
Holtekamp 20MW
Beam shading factor (linear calculation) : Iso-shadings curves
4
Attenuation for diffuse: 0.012
and albedo: 0.570
75 Shading loss: 20 % 3
6 Shading loss: 40 %
7 12h 11h
2
1
13h
60 10h
Sun height [[°]]
14h
9h
45
PVsyst TRIAL
15h
8h
30 1: 22 june
2: 22 may - 23 july
16h 3: 20 apr - 23 aug 7h
4: 20 mar - 23 sep
5: 21 feb - 23 oct
15
6: 19 jan - 22 nov
17h
7: 22 december
Behind Behind
the plane the plane
0
180 150 120 90 60 30 0 -30 -60 -90 -120 -150 -180
Azimuth [[°]]
PVsyst TRIAL
PV modules Model CS6U - 325P Pnom 325 Wp
PV Array Nb. of modules 39996 Pnom total 12999 kWp
Inverter Model SG2000 Pnom 2000 kW ac
Inverter pack Nb. of units 5.0 Pnom total 10000 kW ac
User's needs Unlimited load (grid)
Normalized productions (per installed kWp): Nominal power 12999 kWp Performance Ratio PR
6 1.0
Lc : Collection Loss (PV-array losses) 0.84 kWh/kWp/day PR : Performance Ratio (Yf / Yr) : 0.806
0.9
Ls : System Loss (inverter, ...) 0.11 kWh/kWp/day
PVsyst TRIAL
5 Yf : Produced useful energy (inverter output) 3.93 kWh/kWp/day
0.8
[kWh/kWp/day]
0.7
Performance Ratio PR
4
0.6
Energy
3 0.5
0.4
Normalized
2
0.3
0.2
1
0.1
0 0.0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
PVsyst TRIAL
Holtekamp 1
Balances and main results
PVsyst TRIAL
October 158.0 79.87 27.94 154.6 146.8 1653 1614 0.803
November 149.3 81.23 27.36 142.1 134.6 1531 1495 0.809
December 145.1 75.04 27.64 135.7 128.3 1462 1427 0.809
Legends: GlobHor Horizontal global irradiation GlobEff Effective Global, corr. for IAM and shadings
DiffHor Horizontal diffuse irradiation EArray Effective energy at the output of the array
T_Amb Ambient Temperature E_Grid Energy injected into grid
GlobInc Global incident in coll. plane PR Performance Ratio
PVsyst TRIAL
PV modules Model CS6U - 325P Pnom 325 Wp
PV Array Nb. of modules 39996 Pnom total 12999 kWp
Inverter Model SG2000 Pnom 2000 kW ac
Inverter pack Nb. of units 5.0 Pnom total 10000 kW ac
User's needs Unlimited load (grid)
80000
Values from 01/01 to 31/12
70000
Energy injected into grid [kWh/day]
60000
40000
30000
20000
10000
0
0 2 4 6 8 10
Global incident in coll. plane [kWh/m².day]
300000
250000
200000
PVsyst TRIAL
150000
100000
50000
0
0 2000 4000 6000 8000 10000
Power injected into grid [kW]
PVsyst TRIAL
PV modules Model CS6U - 325P Pnom 325 Wp
PV Array Nb. of modules 39996 Pnom total 12999 kWp
Inverter Model SG2000 Pnom 2000 kW ac
Inverter pack Nb. of units 5.0 Pnom total 10000 kW ac
User's needs Unlimited load (grid)
21926 MWh
-2.49% IAM factor on global
-2.00% Soiling loss factor
PVsyst TRIAL
19208 MWh Array virtual energy at MPP
PVsyst TRIAL
PVsyst Evaluation mode
PVSYST V6.81 13/02/20 Page 7/7
PVsyst TRIAL
PV modules Model CS6U - 325P Pnom 325 Wp
PV Array Nb. of modules 39996 Pnom total 12999 kWp
Inverter Model SG2000 Pnom 2000 kW ac
Inverter pack Nb. of units 5.0 Pnom total 10000 kW ac
User's needs Unlimited load (grid)
PVsyst TRIAL
Year-to-year variability Variance 4.7 %
The probability distribution variance is also depending on some system parameters uncertainties
Specified Deviation PV module modelling/parameters 1.0 %
Inverter efficiency uncertainty 0.5 %
Soiling and mismatch uncertainties 1.0 %
Degradation uncertainty 1.0 %
Global variability (meteo + system) Variance 5.0 % (quadratic sum)
0.45
0.40
0.35
Probability distribution
0.30
Probability
0.25
0.20
P90 = 17444110 kWh P10 = 19851502 kWh
0.15
0.10
0.05
PVsyst TRIAL
0.00
16000000 17000000 18000000 19000000 20000000 21000000 22000000
E_Grid system production kWh