DESIGN OF PIPE S

INPUT
Span of Strut
Strut Diameter D_s
Strut Thickness t_s

No. of Flange connections

Steel Yield Strength f_y


Steel Young's Modulus E

Temperature difference ∆_T


Temperature expansion coefficient α_T

unfactored axial force due to earth load


according to SAP200 or Tab. 1 F_1,u

Live load

Safety factors (See. DIN EN 1990/NA, Tab NA.A.1.2(A)-C)

Permanent and Temporary


γ_G
γ_Q
Ψ

Accidental
γ_G
γ_Q
Ψ_temp,1

Steel γ_M0
EC3 -1-1/6.1 γ_M1
γ_M2

Eccentricity e=1/ 0 the join created between waler beam and str
and therefore the eccentricity can be neglecte

Connection type EC3-1-1/6.3.1.1

Boundaring case according to Euler case


(1 to 4)
OUTPUT
Cross Section Area (Pipe)

Flange - outer diameter


Flange - inner diameter
Flange - thickness
Flange - Volume
Flange - Total Volume

Stiffener (Pipe - Flange connection) b


h
l
Stiffener - Volume
Stiffener - Total Volume

Density of Steel
Specific weigth of Steel

Total distributed Death Load


F PIPE STRUTS

Variable Parameters
33 m Additional Input Values
1.22 m
0.025 m
UTILIZATION
1 LC1 (P+T) 1.123 <1 ERROR
LC2 (A) 0.955 <1 OK!
355 N/mm^2
210000 N/mm^2
Following tables don't interact with the main calculation
25 °C
0.0000117 1/°C Calculation of unfactored earth axial force
spacing 6.5 m
angle (90 is straight) 39 degrees
8218.23 kN Earth loads 670 kN/m

1.5 kN/m Axial Force in Strut 6920.164 kN


Tab. 1

1.35
1.50
1.00

1.00
1.00
0.50

1.00
1.00 (1.1 for Germany and 1.0 for Britain)
1.25

en waler beam and strut is casted in place


ntricity can be neglected

2 (hinge connection is case 2)


0.0938551 m^2

1.46 m
1.09 m
0.04 m
0.0296 m^3
0.0296 m^3

0.04 m
0.03 m
0.12 m
0.00014 m^3
0.00346 m^3

7850 kg/m^3
77.01 kN/m^3

7.30 kN/m