GEOTECHNICAL INVESTIGTATION REPORT FOR THE PROPOSED 40M

GROUND BASED TOWER CONSTRUCTIONS

SITE ID : 1377406
SITE NAME : POLKAMPAHAD
SITE ADDRESS : MANDA TIRUPATHI REDDY, S/O NARAYANA
REDDY, SY.NO.5/1, POLKEPAHAD VIL., GOPALPET
M., WANAPARTHI DIST., 5091033
COORDINATES : Lat- 16.419180 Lon- 78.167420

MARCH, 2020

An NABL accrediated Laboratory


Plot No.14, Survey N0.39, Bandlaguda Village,
Uppal Mandal, Medchal District, Pin: 500068
Telangana State
Email - mercuryecon@outlook.com
Mobile - +91 - 9177212643, +91-8374434294
CLIENT : INDUS TOWERS LIMITED

NAME OF THE PROJECT : GEOTECHNICAL INVESTIGTATION REPORT FOR


THE PROPOSED 40M GROUND BASED TOWER
CONSTRUCTIONS

TITLE : GEOTECHNICAL INVESTIGATION REPORT

LOCATION : MANDA TIRUPATHI REDDY, S/O NARAYANA

REDDY, SY.NO.5/1, POLKEPAHAD VIL., GOPALPET

M., WANAPARTHI DIST., 5091033

SADDAM, RUKMINI,
0 3-Mar-20 GT REPORT ESWAR - M.E
M.TECH M.TECH

REV DATE DESCRIPTION PREPARED BY CHECKED BY APPROVED BY


TABLE OF CONTENTS

S.NO. DESCRIPTION PAGE NO


1 INTRODUCTION 4
2 PROJECT SITE LOCATION 4
3 SCOPE OF THE DOCUMENT 4
4 SAILENT FEATURES OF SITE 5
5 EXPLORATION PROGRAMME 5
6 METHODOLOGY OF FIELD EXPLORATION 5
7 GEOTECHNICAL LABORATORY TESTING 5
8 OPEN PIT LOG & LABORATORY TEST RESULTS 6
9 SITE PHOTOGRAPHS 7
10 DESIGN METHODOLOGY 8
11 FOUNDATION RECOMMENDATIONS 9
12 CERTIFICATION 10
13 LIMITATIONS 10
14 REFERENCES 10

LIST OF ANNEXURES
Annexure -1 - SBC Calculations
Annexure -2 - Key Plan and Layout
GEOTECHNICAL INVESTIGATION REPORT

GEOTECHNICAL INVESTIGTATION REPORT FOR THE PROPOSED 40M GROUND BASED


PROJECT:
TOWER CONSTRUCTIONS
SITE ID: 1377406 SITE NAME: POLKAMPAHAD
1.INTRODUCTION
M/s INDUS TOWERS Ltd. proposed the construction of Geotechnical Investigtation Report For
The Proposed 40M Ground Based Tower Constructions at Manda Tirupathi Reddy, S/O Narayana
Reddy, Sy.No.5/1, Polkepahad Vil., Gopalpet M., Wanaparthi Dist., 5091033 . In this connection
M/s INDUS TOWERS Ltd. has appointed M/s Mercury Engineering Consultancy to provide
consultancy services for Geotechnical investigations. The site investigation works were
conducted on 2/03/2020.
The main text of the report includes description of field explorations, laboratory testing,
subsurface conditions, conclusions and recommendations based upon the review of existing
data, engineering studies and analysis.
2. PROJECT SITE LOCATION
The Project site is located nearby Manda Tirupathi Reddy, S/O Narayana Reddy, Sy.No.5/1,
Polkepahad Vil., Gopalpet M., Wanaparthi Dist., 5091033 . The below Figure 1 shows the Project
site location (Google image).

Figure 1 : Proposed Site Location (Google Image)


3. SCOPE OF THE DOCUMENT
This document presents the foundation recommendations for the proposed 40M Ground Based
Tower Structure at Manda Tirupathi Reddy, S/O Narayana Reddy, Sy.No.5/1, Polkepahad Vil.,
Gopalpet M., Wanaparthi Dist., 5091033 with following contents
--> Open-pit Location
--> Sailent Features of site
--> Methodology of Geotechnical Investigation
--> Laboratory testing on soil samples
--> Site Photographs
--> Design Methodology
--> Foundation Recommendations
--> Certifications, Limitations and References
--> Sample SBC Calculations

MEC_IN-1377406_POLP11_MAR2020_GTREPORT_38 PAGE NO.4


GEOTECHNICAL INVESTIGATION REPORT

GEOTECHNICAL INVESTIGTATION REPORT FOR THE PROPOSED 40M GROUND BASED


PROJECT:
TOWER CONSTRUCTIONS
SITE ID: 1377406 SITE NAME: POLKAMPAHAD

4. SAILENT FEATURES OF SITE


a Weather condition : Dry
b Ground/seepage water level : -
c Water depth at open well : 60 m
d Water depth at tube well : -
e General terrain : Plain
f Site to road distance : -
g Site level v/s road level : -
h Bore distance : 20 m away
i Bore total depth : 60 m
j Bore is before : -
k Important landmark (if any) : house, 20 m away
l Water bodies (if any) : Pond, 500 m away
m Well distance : -
n Electric lines/pole distance (if any) : 40 m away
o Transformers (if any) : -
p Schools (if any) : -
q Mobiles towers (if any) : -
r Railway track (if any) : -
5. EXPLORATION PROGRAMME
The Subsurface investigations have been carried out at the proposed locations using Open-Pit
excavation and Disturbed samples were collected at two different depths of 2m and 3m. Details
of the investigation are given in table below

Open Pit Coordinates Depth of


Structure Location
No. Latitude Longitude Exploration (m)
2.00
Polkampahad 1 16.419180 78.167420
3.00
6. METHODOLOGY OF FIELD EXPLORATION
The Geo-technical investigation is carried out by Open-Pit excavation method and disturbed
samples (D.S) were collected as per IS: 1892 guidelines.
In this method, Open-Pit is excavated at the site and there by collecting the disturbed samples
from the exposed pit.
7. GEO-TECHNICAL LABORATORY TESTING
Laboratory tests are performed on the collected samples and following tests conducted as per
procedures given in relevant IS codes.
--> Grain Size Analysis
--> Atterberg Limits
--> Free Swell Index (F.S.I)
--> Direct Shear Test – for shear properties of Cohesion (C) and Friction Angle (Φ) on remolded
specimen compacted to Field dry density (F.D.D) & Natural moisture content (N.M.C).

MEC_IN-1377406_POLP11_MAR2020_GTREPORT_38 PAGE NO.5


GEOTECHNICAL INVESTIGATION REPORT

GEOTECHNICAL INVESTIGTATION REPORT FOR THE PROPOSED 40M GROUND BASED


PROJECT:
TOWER CONSTRUCTIONS
SITE ID: 1377406 SITE NAME: POLKAMPAHAD

8. OPEN PIT LOG & LABORATORY TEST RESULTS

Depth,m Log Type of Sample Description Remarks


0.00

Disturbed
Light Brownish Silty Sand -
Sample

2.00

Disturbed
Light Brownish Silty Sand -
Sample

3.00

LABORATORY TEST RESULTS


Atterberg Shear Parameters
Grain Size Analysis
Free Swell Index
IS Classification

Limits by Direct Shear


Plasticity Index
Medium Sand
Coarse Sand

Friction, Phi
Plastic Limit

Cohesion, C
Liquid limit

Depth,m
Fine Sand

Angle of
Internal
Gravel

Fines

% % % % % % % % % t/m2 Deg
2.00 22.5 21.3 23.6 17.7 14.9 SM NP NP NP 0 0 30

3.00 24.3 22.1 22.5 17.0 14.1 SM NP NP NP 0 0 31

MEC_IN-1377406_POLP11_MAR2020_GTREPORT_38 PAGE NO.6


GEOTECHNICAL INVESTIGATION REPORT

GEOTECHNICAL INVESTIGTATION REPORT FOR THE PROPOSED 40M GROUND BASED


PROJECT:
TOWER CONSTRUCTIONS
SITE ID: 1377406 SITE NAME: POLKAMPAHAD
9. SITE PHOTOGRAPHS

MEC_IN-1377406_POLP11_MAR2020_GTREPORT_38 PAGE NO.7


GEOTECHNICAL INVESTIGATION REPORT

GEOTECHNICAL INVESTIGTATION REPORT FOR THE PROPOSED 40M GROUND BASED


PROJECT:
TOWER CONSTRUCTIONS
SITE ID: 1377406 SITE NAME: POLKAMPAHAD
10. DESIGN METHODOLOGY
By observing the nature of subsurface strata, the type of foundation for a given proposed
structure, expected loads on foundations, the following types of foundations can be
recommended.
a. Shallow Foundations
For satisfactory performance of a foundation, the following criteria must be satisfied;
I The foundation must not fail in shear.
II The foundation should not settle by an amount more than the permissible settlement.The
smaller of the bearing pressure values obtained according to above (I) and (II), is adopted as
the allowable bearing capacity
Depth of Analysis
In case of Shallow foundation for footing resting on multilayer deposits, weighted average or
average of the 'C' and 'ɸ' values upto a depth of 'H' = 0.5 B Tan (45 + ɸ/2)
Foundation in Soil
A foundation must have an adequate depth from the considerations of adverse environmental
influences. It must also be economically feasible in terms of overall structure. Depth of
foundation in soil shall be decided as per site conditions and structural requirements and
confirmed with clause 7 of IS: 1904 for special cases like; where volume change/scour is
expected/ when foundation is to rest on sloping ground/ made or filled up ground/ frost action is
expected etc.
Open/Shallow Foundations In Soil
The safe bearing capacity of soil is the net intensity of loading which the foundation will carry,
without under- going settlement in excess of the permissible value for the structure under
consideration.
Net safe bearing capacity from shear consideration
For Clay Soils (ɸ = 0)
The net ultimate bearing capacity immediately after construction on fairly saturated
homogeneous cohesive soils shall be calculated using following equation.
qd = C x Nc x Sc x dc x ic Where Nc = 5.14
The value of 'C' shall be obtained from unconfined compressive strength test or static cone
penetration test or triaxial shear (UU) test.
Alternatively, Net ultimate bearing capacity can be determined by using the following equation;

qd = C x Nc x Sc x dc x ic Where Nq = Net Ultimate Bearing Capacity


A factor of safety of 2.5 is used Considering ɸ = 0, Nc = 5.14 Thus, the equation is simplified as

q(Net Safe) = 1/ 2.5 x C x 5.14 x Sc x dc


= 2.056 x C x Sc x dc

MEC_IN-1377406_POLP11_MAR2020_GTREPORT_38 PAGE NO.8


GEOTECHNICAL INVESTIGATION REPORT

GEOTECHNICAL INVESTIGTATION REPORT FOR THE PROPOSED 40M GROUND BASED


PROJECT:
TOWER CONSTRUCTIONS
SITE ID: 1377406 SITE NAME: POLKAMPAHAD
For C - ɸsoils:
For General shear = ɸ ≥ 360 and C ≥ 5 t/m2
qd = C Nc Sc dc ic + q (Nq-1) Sq dq iq + 0.5 γ B Nγ Sγ dγ iγ W'
0 2
For Local shear ɸ ≤ 28 and C ≤ 3 t/m
qd = (2/3) c Nc Sc dc ic + q (Nq-1) Sq dq iq + 0.5 γ B Nγ Sγ dγ iγ W'
For Intermediate Shear
Average or interpolate between Local and General Shear.
Reduction Factors:
Bearing Capacity Factors Nc, Nq, Ny from Table 1 of IS: 6403-1981
Shape factors Sc, Sq, Sy from Table 2 of IS: 6403 – 1981
Depth factors dc, dq, dy from clause 5.1.2.2 of IS: 6403 – 1981
Inclination factors ic iq iy from clause 5.1.2.3 of IS: 6403 - 1981
Net Safe Bearing Capacity
Net safe bearing capacity is obtained by dividing the above Net Ultimate bearing capacity by the
factor of safety of 2.5.
1
Net Safe Bearing Capacity = × Net ultimate bearing capacity
FOS
11. FOUNDATION RECOMMENDATIONS
Structure : 40M Ground Based Tower Structure
Foundation Type : Isolated Footing

Foundation Sizes
Fdt.
Foundation Strata 2.0 x 2.0 3.0 x 3.0 4.0 x 4.0 5.0 x 5.0 6.0 x 6.0
Depth,m
Safe Bearing Capacity t/m2
Light Brownish Silty
2.0 13 14 15 16 18
Sand
Light Brownish Silty
2.5 15 16 17 19 20
Sand
Light Brownish Silty
3.0 21 21 22 24 25
Sand
NOTE:
1 Prior to construction of any new foundations, all areas receiving fill, base rock, or structures
should be Removed/stripped of all surface vegetation, organic topsoil and any deleterious
materials that might be encountered.
2 Any Soft or unsuitable soils encountered during stripping or excavation should also be
removed and replaced with structural fill meeting the requirements.
3 For Un-tested Depths, the test results of immediate depths were considered for designing

4 The recommendation given are based on the provided data, in case of additional loads such
as horizontal loads and overturning moments, necessary corrections such as area reduction
due to eccentricity, shall be done by the structural engineer

MEC_IN-1377406_POLP11_MAR2020_GTREPORT_38 PAGE NO.9


GEOTECHNICAL INVESTIGATION REPORT

GEOTECHNICAL INVESTIGTATION REPORT FOR THE PROPOSED 40M GROUND BASED


PROJECT:
TOWER CONSTRUCTIONS
SITE ID: 1377406 SITE NAME: POLKAMPAHAD
12. CERTIFICATION
For Indus Towers Limited we (MEC) have proposed to built a 40M Ground Based Tower Structure
Manda Tirupathi Reddy, S/O Narayana Reddy, Sy.No.5/1, Polkepahad Vil., Gopalpet M.,
Wanaparthi Dist., 5091033 . Geotechnical Investigation was conducted at the site on 2/03/2020.
After analysis of the Test reports, it is recommended that ISOLATED FOUNDATION To be used for
Design purpose with SOIL BEARING CAPACITY of 21 t/m2 at a DEPTH of 3 m below ground level.
RECOMMENDATIONS
SBC @ 2 m 14 t/m2
SBC @ 2.5 m 16 t/m2
SBC @ 3 m 21 t/m2
Seepage/ Water Table Not Encountered
Type of Foundation ISOLATED FOUNDATION
Width of Foundation 3.0 m

13. LIMITATIONS
The recommendations presented in this report are based on subsurface exploration, field tests
and Laboratory tests of the specified site. There is always a possibility that the observed soil
strata in the Open pit may differ to the actual field strata observed during construction, which
may be due to the limitations in exploration. If such conditions are encountered during
construction, the concerned personal at construction is requested to notify the same
immediately to the designer.

It is the Duty of the Structural Engineer in charge to give provisions for the effect of horizontal
loads, resulting moment and eccentricity effect on the whole structure. Suitable solution should
be derived to counter the abnormalities such as overturning due to moment, by the Structural
Engineer.

14. REFERENCES
IS 6403 - 1981: "Code of practice for determination of bearing capacity of shallow
-->
foundations"
--> IS 1892 - 1979: “Code of practice for sub surface investigation for foundations”
--> IS 2720 (Part 1 to 40): Laboratory Testing on Soils
--> IS: 1498 – 1970: “Classification and Identification of Soils for General Engineering Purpose”

--> IS 4091 – 1979: “Code of practice for design and construction of foundations for
transmission line towers and poles”

FOR MERCURY ENGINEERING CONSULTANCY

MEC_IN-1377406_POLP11_MAR2020_GTREPORT_38 PAGE NO.10


ANNEXURE -1
SAFE BEARING CAPACITY CALCULATIONS
Approved by Checked by Prepared by Rev. no. Date
SHALLOW FOUNDATION CALCULATIONS
Eswar Rukmini Saddam 0 3 Mar 2020
Spread /
Type of Open foundation = - SUMMARY OF FOUNDATION RECOMMENDATIONs
Isolated
Shape of foundation = Square - Width of Foundation = 2.0 m Recommended SBC @2m = 13 t/m2
Width / Diameter of footing = 2.0 m Length of Foundation = 2.0 m Recommended SBC @2.5m = 15 t/m2
Length of footing = 2.0 m Recommended SBC @3m = 21 t/m2
Ground water table (GWT) = 0.00 m
Inclination angle () = 0.00 Deg General = C Nc Sc dc ic + g Df (Nq – 1) Sq dq iq + 0.5 g B Ng Sg dg ig W'
Water table corretion factor (W') = 0.50 - Local = 2/3 C N'c Sc dc ic + g Df (N'q – 1) Sq dq iq + 0.5 g B N'g Sg dg ig W'
Factor of safety (FOS) = 2.50 - Interpolation 1/2 {[C Nc Sc dc ic + g Df (Nq – 1) Sq dq iq + 0.5 g B Ng Sg dg ig W'] + [2/3 C N'c Sc dc ic + g Df
=
Ground R.L = 0.000 m (N'q – 1) Sq dq iq + 0.5 g B N'g Sg dg ig W']}

SHEAR CRITERIA (Ref. IS: 6403- 2000)


FIELD TEST DATA SHEAR PARAMETERS BEARING CAPACITY SHAPE DEPTH INCLINATION

Effective unit

capacity (qu)

capacity (qd)
Ultimate

Net safe
bearing

bearing
weight
Cohesion

Reduced
Internal
friction

friction
angle

angle
Type of Shear
Depth RL
Strata description failure Nc Nq Ng N'c N'q N'g Sc Sq Sg dc dq dg ic iq ig

m m t/m 2 Deg deg t/m 3 t/m 2 t/m 2


2.00 -2.000 Light Brownish Silty Sand 0.00 30 22 Intermediate 0.85 30.1 18.4 22.4 17.2 8.1 7.6 1.3 1.2 0.8 1.3 1.2 1.2 1.0 1.0 1.0 44 17
2.50 -2.500 Light Brownish Silty Sand 0.00 30 22 Intermediate 0.85 30.1 18.4 22.4 17.2 8.1 7.6 1.3 1.2 0.8 1.4 1.2 1.2 1.0 1.0 1.0 54 21
3.00 -3.000 Light Brownish Silty Sand 0.00 31 22 Intermediate 0.85 33.3 21.4 27.5 17.2 8.1 7.6 1.3 1.2 0.8 1.5 1.3 1.3 1.0 1.0 1.0 72 29
Approved by Checked by Prepared by Rev. no. Date
SHALLOW FOUNDATION CALCULATIONS
Eswar Rukmini Saddam 0 3 Mar 2020
Spread /
Type of Open foundation = - SUMMARY OF FOUNDATION RECOMMENDATIONs
Isolated
Shape of foundation = Square - Width of Foundation = 3.0 m Recommended SBC @2m = 14 t/m2
Width / Diameter of footing = 3.0 m Length of Foundation = 3.0 m Recommended SBC @2.5m = 16 t/m2
Length of footing = 3.0 m Recommended SBC @3m = 21 t/m2
Ground water table (GWT) = 0.00 m
Inclination angle () = 0.00 Deg General = C Nc Sc dc ic + g Df (Nq – 1) Sq dq iq + 0.5 g B Ng Sg dg ig W'
Water table corretion factor (W') = 0.50 - Local = 2/3 C N'c Sc dc ic + g Df (N'q – 1) Sq dq iq + 0.5 g B N'g Sg dg ig W'
Factor of safety (FOS) = 2.50 - Interpolation = 1/2 {[C Nc Sc dc ic + g Df (Nq – 1) Sq dq iq + 0.5 g B Ng Sg dg ig W'] + [2/3 C N'c Sc dc ic + g Df
Ground R.L = 0.000 m (N'q – 1) Sq dq iq + 0.5 g B N'g Sg dg ig W']}

SHEAR CRITERIA (Ref. IS: 6403- 2000)


FIELD TEST DATA SHEAR PARAMETERS BEARING CAPACITY SHAPE DEPTH INCLINATION

Effective unit

capacity (qu)

capacity (qd)
Ultimate

Net safe
bearing

bearing
weight
Cohesion

Reduced
Internal
friction

friction
angle

angle
Type of Shear
Depth RL
Strata description failure Nc Nq Ng N'c N'q N'g Sc Sq Sg dc dq dg ic iq ig

m m t/m 2 Deg deg t/m 3 t/m 2 t/m 2


2.00 -2.000 Light Brownish Silty Sand 0.00 30 22 Intermediate 0.85 30.1 18.4 22.4 17.2 8.1 7.6 1.3 1.2 0.8 1.2 1.1 1.1 1.0 1.0 1.0 47 19
2.50 -2.500 Light Brownish Silty Sand 0.00 30 22 Intermediate 0.85 30.1 18.4 22.4 17.2 8.1 7.6 1.3 1.2 0.8 1.3 1.1 1.1 1.0 1.0 1.0 56 22
3.00 -3.000 Light Brownish Silty Sand 0.00 31 22 Intermediate 0.85 33.3 21.4 27.5 17.2 8.1 7.6 1.3 1.2 0.8 1.4 1.2 1.2 1.0 1.0 1.0 74 30
Approved by Checked by Prepared by Rev. no. Date
SHALLOW FOUNDATION CALCULATIONS
Eswar Rukmini Saddam 0 3 Mar 2020
Spread /
Type of Open foundation = - SUMMARY OF FOUNDATION RECOMMENDATIONs
Isolated
Shape of foundation = Square - Width of Foundation = 4.0 m Recommended SBC @2m = 15 t/m2
Width / Diameter of footing = 4.0 m Length of Foundation = 4.0 m Recommended SBC @2.5m = 17 t/m2
Length of footing = 4.0 m Recommended SBC @3m = 22 t/m2
Ground water table (GWT) = 0.00 m
Inclination angle () = 0.00 Deg General = C Nc Sc dc ic + g Df (Nq – 1) Sq dq iq + 0.5 g B Ng Sg dg ig W'
Water table corretion factor (W') = 0.50 - Local = 2/3 C N'c Sc dc ic + g Df (N'q – 1) Sq dq iq + 0.5 g B N'g Sg dg ig W'
Factor of safety (FOS) = 2.50 - Interpolation = 1/2 {[C Nc Sc dc ic + g Df (Nq – 1) Sq dq iq + 0.5 g B Ng Sg dg ig W'] + [2/3 C N'c Sc dc ic + g Df
Ground R.L = 0.000 m (N'q – 1) Sq dq iq + 0.5 g B N'g Sg dg ig W']}

SHEAR CRITERIA (Ref. IS: 6403- 2000)


FIELD TEST DATA SHEAR PARAMETERS BEARING CAPACITY SHAPE DEPTH INCLINATION

Effective unit

capacity (qu)

capacity (qd)
Ultimate

Net safe
bearing

bearing
weight
Cohesion

Reduced
Internal
friction

friction
angle

angle
Type of Shear
Depth RL
Strata description failure Nc Nq Ng N'c N'q N'g Sc Sq Sg dc dq dg ic iq ig

m m t/m 2 Deg deg t/m 3 t/m 2 t/m 2


2.00 -2.000 Light Brownish Silty Sand 0.00 30 22 Intermediate 0.85 30.1 18.4 22.4 17.2 8.1 7.6 1.3 1.2 0.8 1.2 1.1 1.1 1.0 1.0 1.0 52 21
2.50 -2.500 Light Brownish Silty Sand 0.00 30 22 Intermediate 0.85 30.1 18.4 22.4 17.2 8.1 7.6 1.3 1.2 0.8 1.2 1.1 1.1 1.0 1.0 1.0 60 24
3.00 -3.000 Light Brownish Silty Sand 0.00 31 22 Intermediate 0.85 33.3 21.4 27.5 17.2 8.1 7.6 1.3 1.2 0.8 1.3 1.1 1.1 1.0 1.0 1.0 78 31
Approved by Checked by Prepared by Rev. no. Date
SHALLOW FOUNDATION CALCULATIONS
Eswar Rukmini Saddam 0 3 Mar 2020
Spread /
Type of Open foundation = - SUMMARY OF FOUNDATION RECOMMENDATIONs
Isolated
Shape of foundation = Square - Width of Foundation = 5.0 m Recommended SBC @2m = 16 t/m2
Width / Diameter of footing = 5.0 m Length of Foundation = 5.0 m Recommended SBC @2.5m = 19 t/m2
Length of footing = 5.0 m Recommended SBC @3m = 24 t/m2
Ground water table (GWT) = 0.00 m
Inclination angle () = 0.00 Deg General = C Nc Sc dc ic + g Df (Nq – 1) Sq dq iq + 0.5 g B Ng Sg dg ig W'
Water table corretion factor (W') = 0.50 - Local = 2/3 C N'c Sc dc ic + g Df (N'q – 1) Sq dq iq + 0.5 g B N'g Sg dg ig W'
Factor of safety (FOS) = 2.50 - Interpolation = 1/2 {[C Nc Sc dc ic + g Df (Nq – 1) Sq dq iq + 0.5 g B Ng Sg dg ig W'] + [2/3 C N'c Sc dc ic + g Df
Ground R.L = 0.000 m (N'q – 1) Sq dq iq + 0.5 g B N'g Sg dg ig W']}

SHEAR CRITERIA (Ref. IS: 6403- 2000)


FIELD TEST DATA SHEAR PARAMETERS BEARING CAPACITY SHAPE DEPTH INCLINATION

Effective unit

capacity (qu)

capacity (qd)
Ultimate

Net safe
bearing

bearing
weight
Cohesion

Reduced
Internal
friction

friction
angle

angle
Type of Shear
Depth RL
Strata description failure Nc Nq Ng N'c N'q N'g Sc Sq Sg dc dq dg ic iq ig

m m t/m 2 Deg deg t/m 3 t/m 2 t/m 2


2.00 -2.000 Light Brownish Silty Sand 0.00 30 22 Intermediate 0.85 30.1 18.4 22.4 17.2 8.1 7.6 1.3 1.2 0.8 1.1 1.1 1.1 1.0 1.0 1.0 56 22
2.50 -2.500 Light Brownish Silty Sand 0.00 30 22 Intermediate 0.85 30.1 18.4 22.4 17.2 8.1 7.6 1.3 1.2 0.8 1.2 1.1 1.1 1.0 1.0 1.0 64 26
3.00 -3.000 Light Brownish Silty Sand 0.00 31 22 Intermediate 0.85 33.3 21.4 27.5 17.2 8.1 7.6 1.3 1.2 0.8 1.2 1.1 1.1 1.0 1.0 1.0 83 33
Approved by Checked by Prepared by Rev. no. Date
SHALLOW FOUNDATION CALCULATIONS
Eswar Rukmini Saddam 0 3 Mar 2020
Spread /
Type of Open foundation = - SUMMARY OF FOUNDATION RECOMMENDATIONs
Isolated
Shape of foundation = Square - Width of Foundation = 6.0 m Recommended SBC @2m = 18 t/m2
Width / Diameter of footing = 6.0 m Length of Foundation = 6.0 m Recommended SBC @2.5m = 20 t/m2
Length of footing = 6.0 m Recommended SBC @3m = 25 t/m2
Ground water table (GWT) = 0.00 m
Inclination angle () = 0.00 Deg General = C Nc Sc dc ic + g Df (Nq – 1) Sq dq iq + 0.5 g B Ng Sg dg ig W'
Water table corretion factor (W') = 0.50 - Local = 2/3 C N'c Sc dc ic + g Df (N'q – 1) Sq dq iq + 0.5 g B N'g Sg dg ig W'
Factor of safety (FOS) = 2.50 - Interpolation = 1/2 {[C Nc Sc dc ic + g Df (Nq – 1) Sq dq iq + 0.5 g B Ng Sg dg ig W'] + [2/3 C N'c Sc dc ic + g Df
Ground R.L = 0.000 m (N'q – 1) Sq dq iq + 0.5 g B N'g Sg dg ig W']}

SHEAR CRITERIA (Ref. IS: 6403- 2000)


FIELD TEST DATA SHEAR PARAMETERS BEARING CAPACITY SHAPE DEPTH INCLINATION

Effective unit

capacity (qu)

capacity (qd)
Ultimate

Net safe
bearing

bearing
weight
Cohesion

Reduced
Internal
friction

friction
angle

angle
Type of Shear
Depth RL
Strata description failure Nc Nq Ng N'c N'q N'g Sc Sq Sg dc dq dg ic iq ig

m m t/m 2 Deg deg t/m 3 t/m 2 t/m 2


2.00 -2.000 Light Brownish Silty Sand 0.00 30 22 Intermediate 0.85 30.1 18.4 22.4 17.2 8.1 7.6 1.3 1.2 0.8 1.1 1.1 1.1 1.0 1.0 1.0 61 24
2.50 -2.500 Light Brownish Silty Sand 0.00 30 22 Intermediate 0.85 30.1 18.4 22.4 17.2 8.1 7.6 1.3 1.2 0.8 1.1 1.1 1.1 1.0 1.0 1.0 69 28
3.00 -3.000 Light Brownish Silty Sand 0.00 31 22 Intermediate 0.85 33.3 21.4 27.5 17.2 8.1 7.6 1.3 1.2 0.8 1.2 1.1 1.1 1.0 1.0 1.0 88 35