Professional Documents
Culture Documents
offer
April
2018
G8-2
Temperature 12,66 C
Pressure 45,00 bar_g
Std Gas Flow 8,273 MMSCFD
G8-2
G7***-2
G7****-2
Temperature 23,77 C
G7*-2 G7**-2 Temperature 12,66 C
Pressure 69,67 bar_g
Temperature 50,36 C Temperature 42,21 C Pressure 45,00 bar_g
V-105
3 P-101 6
Export Gas to Nawara PPL-2
Temperature 30,53 C
Q-101 Pressure 44,88 bar_g
Std Gas Flow 8,273 MMSCFD
HC Dew Point 12,63 C
Water Dew Point -0,2181 C
Export
Gas to Water Content 132,0 mg/Nm3
Gas/Gas Exchanger-2 Chiller-2
Gas/Liquid Exchanger-2 Nawara
Duty 3,942e+005 Btu/hr Duty 9,855e+005 Btu/hr PPL-2
Duty 1,620e+005 Btu/hr
Tube Inlet Temperature 50,36 C Tube Inlet Temperature 42,21 C
Tube Inlet Temperature 55,00 C
Tube Outlet Temperature 42,21 C Tube Outlet Temperature 23,77 C
Tube Outlet Temperature 50,36 C
Shell Inlet Temperature 12,66 C Shell Inlet Temperature -6,667 C
Shell Inlet Temperature 16,09 C
Shell Outlet Temperature 30,53 C Shell Outlet Temperature -1,044 C
Shell Outlet Temperature 33,53 C
xEDRr: Effective surface area per shell [Calculated] 95,78 ft2 xEDRr: Effective surface area per shell [Calculated] 107,2 ft2
xEDRr: Effective surface area per shell [Calculated] 90,03 ft2
xEDRr: Effective surface area per unit [Calculated] 95,78 ft2 xEDRr: Effective surface area per unit [Calculated] 107,2 ft2
xEDRr: Effective surface area per unit [Calculated] 90,03 ft2
xEDRr: Gross surface area per shell [Calculated] 98,17 ft2 xEDRr: Gross surface area per shell [Calculated] 110,0 ft2
xEDRr: Gross surface area per shell [Calculated] 93,54 ft2
xEDRr: Gross surface area per unit [Calculated] 98,17 ft2 xEDRr: Gross surface area per unit [Calculated] 110,0 ft2
xEDRr: Gross surface area per unit [Calculated] 93,54 ft2
NGL
Temperature 33,53 C
Pressure 76,00 bar_g
Actual Volume Flow 1187 barrel/day
NGL