You are on page 1of 4

UNF, UNL, UNY, UNA unions Cl. I, Div.

1 & 2, Groups A, B, C, DA
Cl. II, Div. 1, Groups E, F, G
Explosionproof
Dust-ignitionproof
4F

4F
and EL elbows Cl. II, Div. 2, Groups F, G
Cl. III

Applications: Certifications and Ordering information:


UNY and UNF unions are installed in compliances:
threaded thick wall conduit systems: NEC/CEC:
UNY male UNF female
• UNY – to connect conduit to a conduit EL 1/2”, 3/4”, 1”
fitting, junction box or device enclosure UNF/UNY -105, -215, -205, -305
• UNF – to connect conduit to conduit, or to UNL -105, -125, -215, -205
provide a means for future modification of • Class I, Divisions 1 & 2, Groups A, B, C, D
the conduit system
• Class II, Division 1, Groups E, F, G
UNA unions are used in conduit and fitting
installations when entrance angle is between • Class II, Division 2, Groups F, G
90° and 180°. • Class III
EL elbows are installed in conduit run or in UNF/UNY -406, -506, -606, -706, -806,
box or fitting hub:
1
/2” - 4” 1
/2” - 4”
-905, -1005
• To change direction in threaded rigid • Class I, Divisions 1 & 2, Groups B, C, D
conduit run by 90°, or when terminating at • Class II, Division 1, Groups E, F, G
a box or fitting
• Class II, Division 2, Groups F, G
• Class III
Features: EL, UNF, UNL, UNY – All Sizes
UNY, UNF and UNL unions have:
• Class I, Divisions 1 & 2, Groups C, D
• Compact design which permits assembly 5” - 6” 5” - 6”
with a minimum of clearance to other • Class II, Division 1, Groups E, F, G
adjacent conduit and/or equipment • Class II, Division 2, Groups F, G
Hub Cat. # Hub Cat. #
• Strong and durable construction • Class III size UNY size UNF
UNA unions: UNA 1
/2“ UNY105 /2“
1
UNF105
• Have a single clamping nut on angle, • Class I, Divisions 1 & 2, Group D
1
/2“ female to UNY215 /4 to /2“
3 1
UNF215
making it both a union and a connector
3
/4“ male
• Class II, Division 1, Groups E, F, G 3
/4“ UNY205 /4“
3
UNF205
• Permit conduit joints at angles between • Class II, Division 2, Groups F, G 1“ UNY305 1“ UNF305
90° and 180° 11/4“ UNY405 11/4“ UNF405
• Class III
EL elbows have a smooth interior and are 11/4“ UNY406 11/4“ UNF406
both strong and compact. UL standard: 11/2“ UNY505 11/2“ UNF505
• UL1203 11/2“ UNY506 11/2“ UNF506
2“ UNY605 2“ UNF605
CSA standard:
Standard materials: 2“ UNY606 2“ UNF606
• C22.2 No. 30 21/2“ UNY705 21/2“ UNF705
•  UNY, UNF unions – 1/2” to 1” and 11/2”:
steel 21/2“ UNY706 21/2“ UNF706
3“ UNY805 3“ UNF805
• UNY, UNF unions – 11/4” to 6”: Feraloy 3“ UNY806 3“ UNF806
iron alloy 31/2“ UNY905 31/2“ UNF905
• UNL, UNA unions – Feraloy iron alloy 4“B UNY1005 4“ UNF1005
5“B UNY012 5“ UNF012
• EL elbows – Feraloy iron alloy or ductile 6“B UNY014 6“ UNF014
iron

UNL 90° angle


Standard finishes:
•  Steel – electrogalvanized with chromate
treatment
• Feraloy iron alloy, malleable iron –
electrogalvanized and aluminum acrylic
paint

Options:
Description Suffix
• Copper-free aluminum........................... SA Hub size Cat. #
Not available on UNA or 5” and 6” UNY/UNF 1
/2“ to 1/2“ UNL105
3
/4“ female to 1/2“ male UNL125
1
/2“ female to 3/4“ male UNL215
3
/4“ to 3/4“ UNL205

ASee Certifications and compliances section for classification of each product.


BNot UL Listed.

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2019 Eaton 79


4F UNF, UNL, UNY, UNA unions Cl. I, Div. 1 & 2, Groups A, B, C, DC
Cl. II, Div. 1, Groups E, F, G
Explosionproof
Dust-ignitionproof
4F
and EL elbows Cl. II, Div. 2, Groups F, G
Cl. III

Dimensions (in inches):

DIA LENGTH
UNY UNL

UNY/UNF UNL
UNY UNF Dim. 105 125 215 205
Hub Max. Max. a 211/16 211/16 27/8 27/8
size Material Length dia. Length dia. b 117/32 113/16 113/16 113/16
1
/2“ Iron 25/8 19/16 127/32 19/16 c 21/16 21/16 21/4 21/4
1
/2“ Aluminum 215/32 11/2 15/8 11/2 d 17/16 17/16 15/8 15/8
3
/4“ Iron 211/16 17/8 131/32 17/8
3
/4“ Aluminum 25/8 125/32 129/32 125/32
3
/4“ - 1/2“ Iron 25/8 17/8 17/8 17/8
3
/4“ - 1/2“ Aluminum 25/8 17/8 17/8 17/8
1“ Iron 3 23/16 23/32 23/16
1“ Aluminum 3 21/32 23/32 21/32
11/4“ Iron 323/32 215/16 21/4 215/16
11/4“ Aluminum 35/8 23/4 21/4 23/4
11/2“ Iron 47/32 31/16 23/4 31/16
11/2“ Aluminum 331/32 31/16 219/32 31/16
2“ Iron 47/32 37/8 211/16 37/8
2“ Aluminum 43/32 37/8 221/32 37/8
21/2“ Iron 513/32 45/32 31/8 45/32
21/2“ Aluminum 511/32 45/8 31/8 45/8
3“ Iron 513/16 51/16 37/16 51/16
3“ Aluminum 525/32 55/32 37/16 55/32
31/2“ Iron 69/16 511/16 41/8 511/16
31/2“ Aluminum 615/32 55/8 41/8 55/8
4“ Iron 65/8 63/16 41/8 63/16
4“ Aluminum 615/32 63/16 41/16 63/16

CSee Certifications and compliances section for classification of each product.

80 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2019 Eaton


UNF, UNL, UNY, UNA unions Cl. I, Div. 1 & 2, Groups C, DD
Cl. II, Div. 1, Groups E, F, G
Explosionproof
Dust-ignitionproof
4F

4F
and EL elbows Cl. II, Div. 2, Groups F, G
Cl. III

Ordering information (continued):


UNA EL

Male
90° male 90° female
(with removable nipple)

Male
Hub size Cat. #
1
/2“ UNA16
3
/4“ UNA26
1” UNA36

45° female 90° male and female

90° male 90° female


Hub size Cat. # Hub size Cat. #
1
/2“ EL195 1
/2“ EL19E
3
/4“ EL295 3
/4“ EL29E
1” EL395 1” EL39E
11/4“ EL49E
45° female
11/2“ EL59E
2“ EL69E
Hub size Cat. # 21/2“ EL79
1
/2“ EL1
3
/4“ EL2 90° male and female
1” EL3
Hub size Cat. #
11/4“ EL4
11/2“ EL5 1
/2“ EL196E
2“ EL6 3
/4“ EL296E
21/2“ EL7 1” EL396E
3“ EL8 11/4“ EL496
31/2“ EL9
4“ EL10

Dimensions (in inches):


UNA EL
90°
Male male
Hub size Length Width 45° 90° 90° and
female male female female
/2“
1
4 /16
5
2 /8
5

/4“
3
413/16 27/8 Hub
size a a a a
1” 511/16 31/2
1
/2“ 13/16 17/16 117/32 117/32
90° male 90° female 3
/4“ 13/8 15/8 13/4 15/8
1” 121/32 17/8 2 17/8
11/4“ 13/4 21/4 21/8
11/2“ 115/16 4
2“ 21/4 5
21/2“ 23/4 67/16
3 31/6
31/2“ 37/16
4“ 35/8
45° female 90° male and female
EL
DSee Certifications and compliances section for classification of each product.
EAvailable in copper-free aluminum. To order, add suffix ‘SA’ to end of catalog number.

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2019 Eaton 81


4F UNY and UNF unions – Cl. I, Div. 1 & 2, Groups A, B, C, D
Cl. II, Div. 1, Groups E, F, G
Explosionproof
Dust-ignitionproof
4F
stainless steel Cl. II, Div. 2, Groups F, G
Cl. III

Applications: Certifications and


UNY and UNF unions are installed in compliances:
threaded thick wall conduit systems:
NEC/CEC:
• UNY – to connect conduit to a conduit
• Class I, Divisions 1 & 2, Groups A, B, C, D
fitting, junction box or device enclosure
• Class II, Division 1, Groups E, F, G
• UNF – to connect conduit to conduit, or to
provide a means for future modification of • Class II, Division 2, Groups F, G
the conduit system • Class III
UL standard:
Features: • UL1203
UNY and UNF unions have: CSA standard:
• Compact design which permits assembly • C22.2 No. 30
with a minimum of clearance to other UNY
adjacent conduit and/or equipment
• Strong and durable construction
Standard material:
• 316 stainless steel

Stainless steel benefits: Standard finish:


• Self-healing properties help reduce the
• Passivated
penetration of rust/corrosion and eliminate
damage to the fitting
• Retain strength in extreme heat and
extreme cold conditions
• Surface is easy to maintain and keep clean
• Easy cleaning capabilities make these
fittings perfect for food processing and
other hygienic areas where wash downs
are common UNF
• Superior strength and durability greatly
reduce replacement – this will lower your
total cost of ownership and increase your
return on investment
• Do not require harsh environment-
damaging cleaners to keep them looking
like new

Ordering information: Dimensions (in inches):


Cat. # Cat. #
Hub size UNY Hub size UNF
1
/2“ UNY105 SS 1
/2“ UNF105 SS
1
/2“ female to UNY215 SS 3
/4“ to 1/2“ UNF215 SS
3
/4“ male
3
/4“ UNY205 SS /4“
3
UNF205 SS
1“ UNY305 SS 1“ UNF305 SS
DIA LENGTH

UNY

UNY UNF
Hub size Length Max. dia. Length Max. dia.
1
/2“ 215/32 11/2 15/8 11/2
3
/4“ 25/8 125/32 129/32 125/32
3
/4“ - 1/2“ 25/8 17/8 17/8 17/8
1“ 3 21/32 23/32 21/32

82 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2019 Eaton

You might also like