You are on page 1of 3

#JRA

@
EPC MEASURING RHS MACHINE
VERIFICATION REPORT
Form No: QSF M 015
Rev 1

DSAW

Verification Report No : 0008 111-18 I VER I MTC

Equipment : RHS Verification Date : 08 Nov 2018


Dsaw Code No. : RHS 09 Verification Due Date : 07 Nov 2019
Type/ Model :RAPID 35 Ambient Temp. : 33.0 °C

Serial No. : PS 35-180 Relative Humidity :57%

Ref Standard Used : Digital Thermoter Code No. : 33.1


: Thermohygro Meter Code No. : TH-10

Reading on TC display to be within ± 10°C


Thermocouple Input Signal Input Signal Input Signal Input Signal
Status
# 100 °C 150 °C 200 °C 400 °C
1 + 0.6 + 0.2 + 0.3 + 0.8 Pass
2 + 0.6 + 0.3 + 0.3 -0.5 Pass
3 + 0.6 + 0.2 +0.4 + 0.6 Pass
4 + 0.7 + 0.7 + 0.6 - 0.3 Pass
5 + 0.6 + 0.2 + 0.4 -0.7 Pass
6 -0.3 + 0.6 + 0.4 -0.9 Pass

Remarks : The Accuracy of the Machine is : 5 %

Verification by Approved by
M:A
®
D SAW
EPC MEASURING RHS MACHINE
VERIFICATION REPORT
Form No : QSF M 015
Rev 1

Verification Report No : 0007 /11-18/ VERI MTC

Equipment : RHS Verification Date : 08 Nov 2018


Dsaw Code No. : RHS 10 Verification Due Date : 07 Nov 2019
Type/ Model :RAPID 35 Ambient Temp. : 33.1 °C

Serial No. : PS 35-191 Relative Humidity :63%

Ref Standard Used : Digital Thermoter Code No. : 33.1


: Thermohygro Meter Code No. : TH-10

Reading on TC display to be within ± 10°C


Thermocouple Input Signal Input Signal Input Signal Input Signal
Status
# 100 °C 150 °C 200 °C 400 °C
1 - 1.8 - 1.6 -1 .8 -6.0 Pass
2 - 1.7 -1 .8 - 1.9 -6.0 Pass
3 - 1.2 -1 .5 - 1.9 -6.2 Pass
4 - 1.7 -1.8 -1.5 -6 .5 Pass
5 - 1.5 -0.6 -1 .8 -6.3 Pass
6 - 1.5 -1.0 - 1.1 -6.4 Pass

Remarks : The Accuracy of the Machine is : 5 %

Verification by
Form No: QSF M 01 6

MJt
@
DSAW
EPC MEASURING RHS RECORDER
VERI FICATION REPORT
Rev 1

Verification Report No : 0020/ 11-18/ VER I MTC

Equipment : RECORDER Verification Date : 13 Nov 2018


Dsaw Code No. : REC 07 Verification Due Date : 12 Nov 2018
Type/ Model : 6100A Ambient Temp. : 28.9 °C
Serial No. : 1 - 8 - 3309 Relative Hum idity : 76 %

Ref Sta ndard Used : Digital Thermo Meter Code No. : 33.1
: Thermohygro Meter Code No. : TH-10

Reading on TC display to be wit hin ± 10°C


Thermocouple Input Signal Input Signal Input Signal Input Signal
Status
# 100 °C 150 °C 200 °C 400°C
1 +5 + 0.8 - 0.2 - 0.2 Pass
2 - 2.2 -2.0 - 0.8 - 1.5 Pass
3 -3.4 - 2.2 - 0.3 -2.5 Pass
4 - 3.3 -2 .5 - 0.5 - 1.7 Pass .
5 -3.0 -1 .6 + 0.6 -0.5 Pass
6 - 4.0 -1 .4 + 0.5 - 1.0 Pass
7 -2.5 -0.5 + 1.7 -0.7 Pass
8 -2.5 -1 .7 - 1.2 - 1.5 Pass
9 -2.7 - 1.3 + 0.1 -2.3 Pass
10 -3.7 -2.3 - 0.3 -1.9 Pass
11 -2.0 -1 .8 - 0.2 -1 .2 Pass
12 -2.0 - 0.3 + 0.6 -0.8 Pass
13 Error Error Error Error Error
14 -2.7 - 4.5 - 2.2 -1 .7 Pass
15 Error Error Error Error Error
16 Error Error Error Error Error
17 - 1.0 -2.9 - 1.0 - 1.4 Pass
18 + 0.5 -1.8 + 0.7 -0.7 Pass

Remarks : The Accuracy of the machine is : 5 %