You are on page 1of 13

RELATIVE PERMEABILITY SATURATION DATA FOR BUCKLEY- LEVERET METHOD (FROM DAKE 1988)

Given data
Sw Krw Kro Case Oil viscosity,cp Water viscosity,cp
0.20 0 0.800 1 50 0.5
0.25 0.002 0.610 2 5 0.5
0.30 0.009 0.470 3 0.4 1.0
0.35 0.020 0.370
0.40 0.033 0.285
0.45 0.051 0.220
0.50 0.075 0.163
0.55 0.100 0.120
0.60 0.132 0.081
0.65 0.170 0.050
0.70 0.208 0.027
0.75 0.251 0.010
0.80 0.300 0

solution

Fractional Flow (fw)


Sw Krw Kro Kro/Krw case1@0.01 case2@0.1 case3@2.5
0.20 0 0.800 inf 0 0 0
0.25 0.002 0.610 305.000 0.247 0.032 0.001
0.30 0.009 0.470 52.222 0.657 0.161 0.008
0.35 0.020 0.370 18.500 0.844 0.351 0.021
0.40 0.033 0.285 8.636 0.921 0.537 0.044
0.45 0.051 0.220 4.314 0.959 0.699 0.085
0.50 0.075 0.163 2.173 0.979 0.821 0.155
0.55 0.100 0.120 1.200 0.988 0.893 0.250
0.60 0.132 0.081 0.614 0.994 0.942 0.395
0.65 0.170 0.050 0.294 0.997 0.971 0.576
0.70 0.208 0.027 0.130 0.999 0.987 0.755
0.75 0.251 0.010 0.040 0.9996 0.996 0.909
0.80 0.300 0 0 1.000 1.000 1.000

From Fig (1) Fig (1)


case Sbwt fbwt fsbwt Avg Swbt RF @ bt , %
1 0.28 0.55 0.61 0.34 18
2 0.45 0.70 0.75 0.55 44
3 0.80 1.00 1.00 0.80 75

Sbwt Values of the shock front and end point relat


case visc (o/w) Swf Krw(Swf) Kro(Swf) Ms M
1 100 0.28 0.006 0.520 1.15
2 10 0.45 0.051 0.220 2.32
3 0.4 0.80 0.300 0 #DIV/0!
Bo, bbl/stb Bw, bbl/stb
1.3 1.0 0.01
1.3 1.0 0.1
1.3 1.0 2.5

Fractional Flow (fw)


1

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2 Vis
Vis
0.1
Vis
0
0.00 0.20 0.40 0.60

Sw

Step 7: define values of mobility ratio,(M) and shock front mobility ratio, (Ms) for the three cases
front and end point relative permeability’s calculated using the data (fractional flow)
Viscosity ratio=0.01
Viscosity ratio=0.1
Viscosity ratio=2.5

.20 0.40 0.60 0.80 1.00

Sw

he three cases
RELATIVE PERMEABILITY SATURATION DATA FOR BUCKLEY- LEVERET METHOD (FROM DAKE 1988)

Given data
Sw Krw Kro Water Flooding
0.20 0 0.800 Oil viscosity,cp 5
0.25 0.002 0.610 Water viscosity,cp 0.5
0.30 0.009 0.470 Bo, bbl/stb 1.3
0.35 0.020 0.370 Bw, bbl/stb 1.0
0.40 0.033 0.285 porosity 0.18
0.45 0.051 0.220 Swc 0.2
0.50 0.075 0.163 Sor 0.2
0.55 0.100 0.120 Dip angle, degree 0
0.60 0.132 0.081 Reservoir thickness, ft 40
0.65 0.170 0.050 Distance between injection wells, ft 625
0.70 0.208 0.027 Distance between injectors and producers, ft 2000
0.75 0.251 0.010 Water injection Rate, b/d/well 1000
0.80 0.300 0

Fractional Flow (fw)


1
solution
0.9

0.1 0.8

Fractional Flow (fw) 0.7


Sw Krw Kro Kro/Krw Water Flooding
0.6
0.20 0 0.800 inf 0
0.25 0.002 0.610 305.000 0.032 0.5
0.30 0.009 0.470 52.222 0.161
0.35 0.020 0.370 18.500 0.351 0.4

0.40 0.033 0.285 8.636 0.537


0.3
0.45 0.051 0.220 4.314 0.699
0.50 0.075 0.163 2.173 0.821 0.2
0.55 0.100 0.120 1.200 0.893 Water Flood
0.1
0.60 0.132 0.081 0.614 0.942
0.65 0.170 0.050 0.294 0.971 0
0.70 0.208 0.027 0.130 0.987 0.00 0.20 0.40 0.60 0.80 1.00
0.75 0.251 0.010 0.040 0.9960
Sw
0.80 0.300 0 0 1.000
From Fig (1) Swbt 0.45
From Fig (1) fwbt 0.70
Widbt=Npbt = Sw-Swbt Dimensionless water influx @bt ,Widbt 0.35
Calculation of the breakthrough time (t), years 1.54

Dimensionless water influx AFTER bt ,Wid


Swe,water saturation at the producing end of the block

From Fig (1) fwe,(Find fw vs each valuw of Swe) From Fig (1)
for column of (Swe) S*we,mid points of each saturation increment, Sw Swe fwe ∆ Swe ∆ fwe ∆ fwe/∆ Swe S*we Wid
0.2 0.45 0.699 - - - - -
0.25 0.5 0.821 0.05 0.122 2.440 0.475 0.410
0.3 0.55 0.893 0.05 0.072 1.440 0.525 0.694
0.35 0.6 0.942 0.05 0.049 0.980 0.575 1.020
0.4 0.65 0.971 0.05 0.029 0.580 0.625 1.724
0.45 0.7 0.987 0.05 0.016 0.320 0.675 3.125
0.5 0.75 0.996 0.05 0.009 0.180 0.725 5.556
0.55 0.8 1 0.05 0.004 0.080 0.775 12.500
0.6 0.85
0.65 0.9
0.7 0.95
0.75 1
0.8 -
From Fig (1)
From Fig (1) f*we, (Find fw for the corresponding values of S*we) S*we Wid (PV) S*we-Swc f*we 1-f*we Npd (PV) Time (years)
- - - - - - -
Npd, The oil recovery after breakthrough, 0.475 0.410 0.275 0.765 0.235 0.371 1.80
0.525 0.694 0.325 0.87 0.130 0.415 3.05
Time (t) ,years 0.575 1.020 0.375 0.925 0.075 0.452 4.48
t=(Wid (625×40×2000×0.18))/(1000×5.615×365)=4.39×Wid 0.625 1.724 0.425 0.962 0.038 0.491 7.57
0.675 3.125 0.475 0.982 0.018 0.531 13.72
0.725 5.556 0.525 0.993 0.007 0.564 24.39
0.775 12.500 0.575

0.6 0.6

0.5 0.5

Notice 0.4 0.4

Npd (PV)
Npd (PV)
0.3 0.3

0.2 0.2

0.1 0.1

0.0 0.0
0 1 2 3 4 5 6 7 0 5 10 15 20 25 30
Wid (PV) time (yrs)

The maximum possible


recovery is one movable
oil volume, i.e.
(1 − Swc − Sor) = 0.6 PV.
RELATIVE PERMEABILITY SATURATION DATA FOR BUCKLEY- LEVERET METHOD (FROM DAKE 1988) (Sami Modified_Feb201

Given data
Sw Krw Kro Case Oil viscosity,cp Water viscosity,cp
0.20 0 0.800 Water 5 0.5
0.25 0.002 0.610 Polymer_1 5 1.5
0.30 0.009 0.470 polymer_2 5 3.0
0.35 0.020 0.370
0.40 0.033 0.285
0.45 0.051 0.220
0.50 0.075 0.163
0.55 0.100 0.120
0.60 0.132 0.081
0.65 0.170 0.050
0.70 0.208 0.027
0.75 0.251 0.010
0.80 0.300 0

solution

Fractional Flow (fw)


Sw Krw Kro Kro/Krw Water Polymer_1 polymer_2
0.20 0 0.800 inf 0 0 0
0.25 0.002 0.610 305.000 0.032 0.011 0.005
0.30 0.009 0.470 52.222 0.161 0.060 0.031
0.35 0.020 0.370 18.500 0.351 0.153 0.083
0.40 0.033 0.285 8.636 0.537 0.278 0.162
0.45 0.051 0.220 4.314 0.699 0.436 0.279
0.50 0.075 0.163 2.173 0.821 0.605 0.434
0.55 0.100 0.120 1.200 0.893 0.735 0.581
0.60 0.132 0.081 0.614 0.942 0.845 0.731
0.65 0.170 0.050 0.294 0.971 0.919 0.850
0.70 0.208 0.027 0.130 0.987 0.963 0.928
0.75 0.251 0.010 0.040 0.9960 0.988 0.977
0.80 0.300 0 0 1.000 1.000 1.000

From Fig (1) Fig (1)


case Sbwt fbwt fsbwt Avg Swbt RF @ bt , %
1 0.45 0.70 0.75 0.55 44
2 0.55 0.74 0.79 0.68 60
3 0.65 0.85 0.88 0.72 65

Sbwt Values of the shock front and end point relat


case visc (o/w) Swf Krw(Swf) Kro(Swf) Ms M
1 10 0.45 0.006 0.520 0.12
2 3.333333 0.55 0.051 0.220 0.77
3 1.666667 0.65 0.300 0 #DIV/0!
(Sami Modified_Feb2018)

Bo, bbl/stb Bw, bbl/stb


1.3 1.0 0.1
1.3 1.0 0.3
1.3 1.0 0.6
Fractional Flow (fw)

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2 Water Flood


Polymer_1
Flood
0.1 Polymer_2
Flood
0
0.00 0.20 0.40 0.60 0.80 1.00

Sw

Step 7: define values of mobility ratio,(M) and shock front mobility ratio, (Ms) for the three cases
front and end point relative permeability’s calculated using the data (fractional flow)
he three cases

You might also like