BX5 - failed 0451 with new machines (SGB142 No. version 1

and FMB130)
011 102 12/27/2016

Responsable Classification:
Responsible: Class: Issuance date:
Department: C2 - Page 1 of 2
Daniel Hiroshi A2 12/27/2016
CR & D Domestic Use

1. HISTORIC:
From the 11:05 version of software was added to brake power monitoring function of the machine in SMIC.

2. PROBLEM:
When applied models of machines or GBS-142 130-VLF power and brake monitoring
no goes by through the SMIC, occurring The failure 0451
"E_DRIVE_BRAKE_SUPPLY_VOLTAGE_FAILURE".

3. CAUSE:
The command monitors the brake power via XTB entry. However, the power does not go through SMIC causing error in
the command and preventing the movement of the elevator.

4. SOLUTION:
Request with the jumper plug 55501525. The code plug contains a jumper between points 1 and 4 and between points 2 and 3, as
shown in Figure 1:

Figure 1 - Plug code 55501525

5. APPLICATION:
Modernization with command BX Rel. 5.

6. PROCEDURE:
In applications with GBS 142 and BSF 130 machines, connect the plug connector in XTB SMIC plate according to figure 2:

This is the impression of a document online for temporary use. To access the version currently in force, check the online document in the system
Domino.doc 6.5 at http: //brsaonn4/dominodoc3lib.nsf with the default user "DOMINODOC" and password "READING"
This document is the intellectual property of Schindler Lifts Atlas SA, and a company of the Schindler Group, and can only be used for
internal purposes and must not be disclosed to third parties without permission.

No. Version: Special information - BX5 - failed 0451 with new machines Page: 2 of 2
011 102 1
(SGB142 and FMB130)

Figure 2 - Entrance XTB

The addition was carried connector in the product structure. In addition, the wiring diagrams have been updated with the
connector, according to the documents listed in the following item.

8. RELATED DOCUMENTS:
S 274 746
274 747 S S
S 277 385
274 748

9. DISCLOSURE OF NEED AND TRAINING FORMAL:


No

disclosure Supervisors, engineers, inspectors and sub-assembly of regional


technical, field engineering, BM-MOD, training center, MOD methods
and processes, operating supervisors, general supervisors operation.

Registration Formal Training No

- End of Document -