a) Details of Specimens 3 and 4
c
I
I
I
- ~ ~ ~Ir
z
-3
- ~.
1I a
'--a
'-1
~ *I
-1
.
- ~,
.
"--10
~ I "
~I II
, 'j
I
I
.
33
Precast Pan.~l
CIP Slab
Slip Ga2e
"
34
CHAPTER 5 -SUMMARY, CONCLUSIONS AND RECOMMENDATIONS
~.! Oenem!
The use of precast concrete for new bridge construction and for tile rehabilitation of
deteriorated bridges is economically and StnlCturally attractive. Durability, ease and speed of
construction, together with reduced need for maintenance are an advantages in using precast
concrete. Precast prestressed concrete bridge deck panels are used with CIP concrete to provide
a convenient and cost effective method of constnlction for concrete bridge decks. In this study,
emphasisis placed on the behavior of stay-in-place precast panels in conjunction with CIP decks
under the action of applied loads. During the past 12 years the consb"Uctioncost of bridge decks
in Indiana has been reduced by the use of precast panels as stay.in.place deck fonDs.
The main objective of this study was to evaluate the horizontal shear friction requirements
for prestresSeddeck panels in bridge constroction with broom fmisbed top surface. CUITently
mDOT requires a total of 20 shear connectors across the interface regardless of panel
dimensions. This study addresses the specific INDOT concerns dealing with the number of
horizontal shear connectors required in precast panels with broom finished top surface. The
issues of potential separation of the precast prestressedpanel from the cast-in-place portion of
the deck, as well as the adequate development of positive moment and sh~Lr capacities of the
202
5.2 Research Prol!ram
To accomplish the objective of this study, an experimental program consisting of six full-
scale composite stay-in-place deck slabs was conducted. These specimens hJid different interface
characteristics including different amounts of horizontal shear reinforcement across the interface.
Specimens 1-4 had 18 presttessing strands representing a practical upper limit on the amount of
flexural reinforcement in this type of member. These specimens were tested to evaluate the
potential maximum horizonta1 shear demand. Specimens Sand 6 had 12 prestressing strands.
These last two specimens were used to evaluate the effect of repeated loading due tO an increase
in mean shear stress at the interface. In addition, these specimens were intended to evaluate the
amount of shear to be transfen-ed in deck panels designed according to AASHTO for HS20
All six composite specimens consisted of a 2.5 in. thick precast prestressed panel with a
5.5 in. thick CIP reinforced concrete topping slab. This provided an 8 in. standard full deck
thickness as commonly used in Indiana. The longitUdinal dimension of the panel depends on the
with a 318 in. diameter. The mild reinforcing steel in the panel was Grade 60 and met the
203
section modulus. The broom finished surface provided defonnations with approximately 0.05 to
0.075 in. amplitude. This is less than the raked surface amplitude of 0.25 in. Strands were
prestressed to about 17.5 kips (COrl'eCtedfor slip loss which was estimated to be approximately
0.3 kips) approximately equal tO 0.75 ~, where fpais the ultimate strand tensile strength. Each
panel had a single layer of welded wire fabric located directly on top of the prestressing strands.
In addition, these panels contained five #3 reinforcing bars placed at 6 in.. 18 in. and 48 in. from
The reinforcement in dIe CIP slab was nominal and placed in the concrete to take care
spaced at 9 in. on centers supported on 1.75 in. high bar chairs spaced at a~)proximately 2 ft on
centers. The bar chairs rested directly on the top surface of the precut panels. The longitudinal
placed on top of the lransverse reinforcomenl All reinforcing bars were AS"fM A61S-90, Grade
60 bars. These bars were not epoxy coated and the clear cover to t11etop bars was 2.5 inches.
End cover was 3 inches. The design concrete compressive strength was 4000 psi.
These specimens were tested under static and cyclic loadings. All loads were applied by
_.
hydraulic actuators. Static load tests were performed at regular intervals of repeated loading. The
specimens were tested under repeated loading to simulate traffic effectS on the horizontal shear
strength of the panel at the interface between the precast panel and the C8S1:-in-place portion of
the deck. Following cyclic loading. the spooimenswere monotonically loaded to failure.
When the load is applied over the wheel foot print, it has been found that punching shear
usually governs the ultimate strength of dle slab in a monotonic loading situation. In thesecases
204