Frame Size: H80-355
Power: 0.75HP-480HP
3000RPM, 1500RPM,
Synchronous Speed:
1000RPM,750RPM
Protection Class: IP44,IP54,IP55
Insulation Class: B, F, H
Cooling Type: IC0141
Frequency: 50Hz,60Hz,50/60Hz
Ambi.Temperature : -15~+40℃
Operation Type: S1
B3, B5, B35, B14, V1, V3, V5, V6,
Mounting: V18, V19, V1/V5, V3/V6,
V5/V18, V6/V9
Technical Data
Synchronous Speed 3000r/min (2 pole),50Hz,380V
Locked Locked
Power Pull out Pull out
Power Current Speed Efficienc rotor rotor Weight
factor torque torque
TYPE torque current
Rated Rated Rated Rated
KW HP (A) (rpm) (%) cosφ (kg)
current current torque torque
Y801-2 0.75 1 1.8 75 0.84 6.5 18
2830
Y802-2 1.1 1.5 2.5 77 0.86 1.5 19
Y90S-2 1.5 2 3.4 78 0.85 22
2840 2.2
Y90L-2 2.2 3 4.7 80.5 0.86 26
Y100L-2 3 4 6.4 2870 82 1.4 36
0.87 2.3
Y112M-2 4 5 8.2 2890 45
85.5
Y132S1-2 5.5 7.5 11 70
2900
Y132S2-2 7.5 10 15 86.2 77
0.88 1.2
Y160M1-2 11 15 22 87.2 122
Y160M2-2 15 20 29 2930 88.2 7 132
Y160L-2 18.5 25 36 150
89
Y180M2 22 30 43 2940 182
2 1.1
Y200L1-2 30 40 57 90 240
2950
Y200L2-2 37 50 70 90.5 255
Y225M-2 45 60 84 309
91.5 1
Y250M-2 55 75 103 403
2970 0.89 2.2
Y280S-2 75 100 140 92 544
Y280M-2 90 125 167 620
92.5
Y315S-2 110 150 200 0.9 980
Y315M-2 132 180 237 93 1080
2980 1.8 6.8
Y315L1-2 160 220 286 1160
93.5
Y315L2-2 200 270 356 0.8 1220
These tables are provided for guidance only. Results are guaranteed only when confirmed by test results.
7 www.injoyindustry.com
Y Series Three Phase Motor
These tables are provided for guidance only. Results are guaranteed only when confirmed by test results.
sales@injoyindustry.com 8
Y Series Three Phase Motor
9 www.injoyindustry.com
Y Series Three Phase Motor
Dimension of B3 Installation
0
80 80-19 125 34 165 175 150 50 100 80 10 170 285 337
-0.5
100 130
90S 90S24 - 10 311 373
0
140 36 180 195 160 56 110 90 12 195
-0.5
90L 90L24 125 155 335 398
0
100L 100L28 160 40 205 215 180 176 63 120 100 14 245 380 445 -
-0.5
0
112L 112M28 190 55 245 240 190 140 180 70 131 112 15 265 400 463
-0.5
12
132S 132S38 200 475 555
0
216 60 280 275 210 89 168 132 18 315
-0.5
132M 132M38 178 238 515 593
0
200L 200L55 318 395 420 315 305 379 133 221 200 25 475 775 879 104
-0.5
0
250M 250M60 250M65 406 80 490 515 385 349 455 168 267 250 30 575 930 1043 130
-0.5
Note: The distance between the shoulder of second shaft extension and the fan cover is about 8mm, and the
dimention of L,LC etc shown in the table above are the maximun values.
sales@injoyindustry.com 10
Y Series Three Phase Motor
Dimension of B5 Installation
Dimension of V1 Installation
11 www.injoyindustry.com
Y Series Three Phase Motor
0
80 80-19F165 125 34 165 175 150 50 100 80 10 170 285 337 245
100 130 -0.5 +0.014
10 13 165 130j6 220 4-Φ12 4
90S 90S24F165 0 311 373 260 -0.011
140 36 180 195 160 56 110 90 12 195
90L 90L24F165 125 155 -0.5 335 398 285
0
100L 100L28F215 160 40 205 215 180 176 63 120 100 14 245 380 445 320
-0.5 +0.014
15 215 180j6 250
140 0 -0.011
112L 112M28F215 190 55 245 240 190 180 70 131 112 15 265 12 400 463 340 4-Φ15 4
-0.5
132S 132S38F265 200 0 475 555 395 +0.016-
216 60 280 275 210 89 168 132 18 315 16 265 230j6 300
132M 132M38F265 178 238 -0.5 515 593 435 0.013
160M 160M42F300 210 266 0 600 715 490
254 325 325 255 108 177 160 20 385 18 55
160L 160L42F300 254 310 -0.5 645 759 535 +0.016-
15 300 250j6 350
180M 180M48F300 241 311 0 670 781 560 0.013 85
299 70 355 360 285 121 199 180 22 430 20 4-Φ19
180L 180L48F300 279 349 -0.5 710 819 600 0 104
0
200L 200L55F300 318 395 420 315 305 379 133 221 200 25 475 775 879 665 350 300j6 ±0.016 400 104
-0.5 -
19 22 5
225S - 225S60F400 286 368 0 820 932 680 100
356 75 435 450 345 149 247 225 28 530 400 350j6 ±0.018 450
225M 225M55F400 225M60F400 311 393 -0.5 815 845 927 957 705 112
0
250M 250M60F500 250M65F500 406 80 490 515 385 349 455 168 267 250 30 575 930 1043 790 8-Φ19 130
-0.5
24 500 450j6 ±0.02 550
280S 280S65F500 280S75F500 368 530 0 1000 1117 1145 860 168
457 85 55O 585 410 190 307 280 35 640
280M 280M65F500 280M75F500 419 581 -1.0 1050 1168 1196 24 910 193
315S 315S65F600 315S80F600 406 602 398 1270 1260 1320 1060 175
0
315M 315M65F600 315M80F600 508 120 744 645 576 457 660 216 315 45 865 1351 1411 600 500j6 ±0.022 660 220
402 -1.0 1340 1180
315L 315L65F600 315L80F600 508 720 28 1421 1481 8-Φ24 6 255
355M 355M75F740 355M95F740 560 0
610 130 730 750 680 808 254 420 355 50 860 1515 1545 1663 1693 30 1374 740 680j6 ±0.025 800 327
355L 355L75F740 355L95F740 630 -1.0
Note: The distance between the shoulder of second shaft extension and the fan cover is about 8mm, and the
dimention of L,LC etc shown in the table above are the maximun values.
sales@injoyindustry.com 12