Professional Documents
Culture Documents
2019-05-26
Page 1
For reference
3. Load Combination
Page 2
For reference
Glass panel largest span: S=2441.1mm
Glass thickness: 8+1.52PVB+8
Fully Tempered Glass ……………(ASTM E-1300 See Appendix B)
Ultimate limit state design stress for glass subjected to wind loading
8mm Fully Tempered Glass (FT) σs1 = 73.0 Mpa
Where: 1 hs h1
0.43 hs ;1 4.68
EI S hv
1 9 .6 2 2 h1 h2
Ghs a
h s h2
I S h1 hs2; 2 h2 hs2;1 491.87 hs ; 2 5 .84
h1 h2
hS 0.5h1 h2 hv 10.52
Page 3
For reference
3. Glass Panel Performance Criteria
Allowable deflection of point supported face glass : S/60……( AS-1288-2006)
4. Load Combination
Working combination (Serviceability limit state)
S-1: D + W
Ultimate combination (Ultimate limit state)
U-1: 1.2D + 1.4W
5. SAP2000 Calculation
Page 4
For reference
Page 5
For reference
6. Conclusion
Deflection Check
Maximum deflection: δmax = 12.741 mm < S/60=30.05 mm ………………...……….. OK
Strength Check
Maximum stress: σmax = 66.768MPa <σs1=73.0 Mpa …..…….………….....OK
Page 6
For reference
1. Load calculation
Axial Force Calculation
Page 7
For reference
Page 8