Reference Manual
Identifier Labels
Relay Identifier (30 characters)
RID =
Enable Settings
Voltage elements (Y, N) (see Figure 1.1, Figure 1.2, and
Figure )
EVOLT =
Synchronizing phase
(VA, VB, VC or 0° to 330° in 30° steps; degree option is for VS
not in phase with VA, VB, or VC—set with respect to VS
constantly lagging VA)
SYNCP =
SELOGIC control equation settings consist of Relay Word bits (see Table ) and SELOGIC control equation
operators * (AND), + (OR), ! (NOT), / (rising edge), \ (falling edge), and ( ) (parentheses). Numerous SELOGIC
control equation settings examples are given in and . SELOGIC control equation settings can also be set directly
to 1 (logical 1) or 0 (logical 0). gives SELOGIC control equation details, examples, and limitations.
SELOGIC Control Equation Variable Timer Input Equations (see Figure 2.3 and Figure )
SELOGIC Control Equation Variable SV1
SV1 =
LED3 (59)
LED3 =
LED4 (81)
LED4 =
LED5 (47)
LED5 =
LED6 (32)
LED6 =
LED7 (25)
LED7 =
Other Equations
Event report trigger conditions (see )
ER =
Fixed Setting
Phase Potential Connection (WYE [fixed setting])
PCONN = WYE
Date Format
Date format (MDY, YMD)
DATE_F =
Protocol Settings
Protocol (SEL, LMD, MOD)
PROTO =
Communications Settings
Baud Rate (300, 1200, 2400, 4800, 9600, 19200)
SPEED =
Setting T_OUT
Set T_OUT to the number of minutes of serial port inactivity for an automatic log out.
Set T_OUT = 0 for no port time out.
This setting is not available on a designated MODBUS port (setting PROTO = MOD).
Setting AUTO
Set AUTO = Y to allow automatic messages at the serial port.
This setting is not available on a designated MODBUS port (setting PROTO = MOD).
Setting RTSCTS
Set RTSCTS = Y to enable hardware handshaking.
With RTSCTS = Y, the relay will not send characters until the CTS input is asserted. Also, if the relay
is unable to receive characters, it deasserts the RTS line.
Setting RTSCTS is only available for serial Port F (EIA-232), when setting PROTO = SEL
(SEL ASCII protocol).
Setting FASTOP
Set FASTOP = Y to enable binary Fast Operate messages at the serial port.
Set FASTOP = N to block binary Fast Operate messages.
This setting is not available on a designated MODBUS port (setting PROTO = MOD).
Refer to on page for the description of the SEL-547 Fast Operate commands.
R.5.14
R.3.12
R.2.32
Section 3
R.2.25
Section 3
2.15
1.4
Section 3
2.6
2.27
2.4
: SELOGIC Control Equation Programming
Section 2
Section 2
Section 1
A.1
2.4
2.3
1.9
1.5
1.4
1.8
1.3
1.2
1.9
2.4
1.8
1.5
1.3