foot/
1 minute
1.1364x10-2 1.0 12.0 0.3048 30.48 1.6667x10-2 20.000 5.08x10-3 5.08
inch/
1 minute
9.470x10-4 8.333x10-2 1.0 2.540x10-2 2.54 1.3888x10-3 1.6666x10-2 4.23x10-4 0.0423
meter/
1 minute
3.7282x10-2 3.281 39.372 1.0 100.0 5.468x10-2 0.6562 1.667x10-2 16.667
centi-
1 minute
meter/ 3.7282x10-4 3.281x10-2 0.3937 0.01 1.0 5.468x10-4 6.5616x10-3 1.667x10-4 0.1667
foot/
1 second
0.6818 60 720 18.29 1829 1.0 12 0.3048 304.8
1 inch/
second 5.6818x10-2 5 60 1.524 152.4 8.333x10-2 1.0 2.540x10-2 25.40
meter/
1 second
2.2369 196.85 2362.2 60.0 6000.0 3.281 39.372 1.0 1000
milli-
1 second
meter/ 2.2369x10-3 0.1969 2.3622 6.0x10-2 6.000 3.281x10-3 3.937x10-2 1x10-3 1.0
millimeter
1 (mm)
1.0x107 1.0 0.1 0.0394 3.2808x10-3 1.0936x10-3 1.0x10-3 1.0x10-6 6.2137x10-7
centimeter
1 (cm)
1.0x108 10.0 1.0 0.3937 0.0328 0.0109 0.01 1.0x10-5 6.2137x10-6
inch
1 (in)
2.54x108 25.4 2.54 1.0 0.0833 0.0278 0.0254 2.54x10-5 1.5783x10-5
foot
1 (ft)
3.048x109 304.8 30.48 12.0 1.0 0.3333 0.3048 3.048x10-4 1.8939x10-4
yard
1 (yd)
9.144x109 914.4 91.44 36.0 3.0 1.0 0.9144 9.144x10-4 5.6818x10-4
meter
1 (m)
1.0x1010 1.0x103 100.0 39.3701 3.2808 1.0936 1.0 1.0x10-3 6.2137x10-4
kilometer
1 (km)
1.0x1013 1.0x106 1.0x105 3.937x104 3.2808x103 1.0936x103 1.0x103 1.0 0.6214
mile
1 (imperial)
1.6093x1013 1.6093x106 1.6093x105 6.336x104 5.280x103 1.760x103 1.6093x103 1.6093 1.0
sin ø = Y/Z
Z cos ø = X/Z
Y tan ø = X/Y
csc ø = Z/Y = 1/sin ø
Ø sec ø = Z/X = 1/cos ø
cot ø = X/Y = 1/tan ø
X
Given ø and X: Y = X tan ø Z = X sec ø Given ø and Z: X = Z cos ø Y = Z sin ø
Given ø and Y: X = Y cot ø Z = Y csc ø Given X and Y: Z = √X2 + Y2 ø = arctan (Y/X)
Ohm's Law Circuit R (ohms) Electrical power may also be quantified in terms of a single
equation. Power is the rate of doing work, and is measured in
units called watts. Watts are equal to voltage x current. DC
+ I (amperes) power equations relate power (in watts), current (in amperes),
E and resistance (in ohms), as follows:
(volts)
P=ExI P = E2 P = I2 x R
– R
The colored bands on the bodies of resistors denote their value (in
TABLE 10. Resistor Color Codes ohms), and their tolerance (in ±%). With the resistor positoned as
shown below, the first two color bands are digits ,the next is the
Color Digit Multiplier Tolerance multiplier, and the next (if present) is the tolerance.
black 0 1 ±1% As an example ,a resistor color-coded YELLOW-VIOLET-BROWN-GOLD
brown 1 10 ±2% would be 47 x 10, ±5% tolerance or: 470 ohms (±5% tolerance).
red 2 100 ±3 % Precision resistors usually have their values stamped on the resistor
orange 3 1000 ±4% body. Some film-type resistors may have three significant figures and,
yellow 4 10000 therefore, use five color bands (including 3 digit bands and 1 multiplier
band).
green 5 100000
blue 6 1000000
violet 7 10000000
gray 8 100000000
white 9
gold 0.1 ±5%
silver 0.01 ±10% Digit 1 Tolerance
no color ±20%
Digit 2 Multiplier
1
Exact diameter is dependent upon the wire gage used for the strands. Diameter listed represents the most common
wire type for AWG.
2
Resistance values assume the resistivity of solid copper wire. Stranding and/or copper alloy increase the resistance values.
DIVISION 2: Locations where combustible dust de- explosion hazard, and having a resistivity greater than 100 ohm-centimeter but equal to or less
posits exist but are not likely to be thrown into than 100,000,000 ohm-centimeter
suspension in the air, but where the dust deposits
may be heavy enough to interfere with safe heat dis-
sipation from electric equipment.
GROUP G:
-or- Locations where combustible dust deposits Atmospheres containing dusts having resistivity of 100,000,000 ohm-centimeter or greater (noncon-
may be ignited by arcs, sparks, or burning material ductive dusts)
from electric equipment.
easily-ignited fibers or flyings, but where the Easily ignitable fibers include: cotton, rayon, sisal, hemp, jute
fibers or flyings are not likely to be in suspen- DIVISION 2: Locations in which easily ignitable
sion in the air in quantities great enough to fibers are stored or handled (except in a manufac-
produce ignitable mixtures. turing process).
Data Reference Tables
TABLE 13. NEMA Enclosure Ratings for Nonhazardous Locations
Hosedown and
Falling liquid,
bodily contact
Oil or coolant
(non-volatile)
Oil or coolant
heavy splash
Standard
Rain, snow,
submersion
submersion
light splash
Ice buildup
Occasional
Falling dirt
Intended
Accidental
Prolonged
Corrosive
NEMA
and sleet
seepage
Use
agents
(IEC)*
NEMA 1 Indoor Yes Yes ... ... ... ... ... ... ... ... ... ... ...
(IP10)
NEMA 2 Indoor Yes Yes ... ... Yes ... ... ... ... ... ... ... ...
(IP11)
NEMA 3 Outdoor Yes Yes Yes Yes Yes ... Yes ... ... ... ... ... ...
(IP54)
NEMA 3S Outdoor Yes Yes Yes Yes Yes ... Yes Yes ... ... ... ... ...
(IP54)
NEMA 4 Indoor or Yes Yes Yes Yes Yes Yes Yes ... ... ... ... ... ...
(IP56) Outdoor
NEMA 4X Indoor or Yes Yes Yes Yes Yes Yes Yes ... ... ... ... ... Yes
(IP56) Outdoor
NEMA 6 Indoor or Yes Yes Yes Yes Yes Yes Yes ... ... ... Yes ... ...
(IP67) Outdoor
NEMA 6P Indoor or Yes Yes Yes Yes Yes Yes Yes ... ... ... Yes Yes Yes
(IP67) Outdoor
NEMA 12 Indoor Yes Yes Yes ... Yes ... ... ... Yes ... ... ... ...
(IP52)
NEMA 13 Indoor Yes Yes Yes ... Yes ... ... ... Yes Yes ... ... ...
(IP54)
*The IEC equivalents listed in this column are approximate: NEMA types meet or exceed the test requirements for the associated IEC classifications.
POOR
Lexan® Attacked by: acetone, GOOD FAIR POOR POOR POOR GOOD
Polycarbonate MEK, and methylene
chloride
FAIR
NORYL® Attacked by: GOOD FAIR EXCELLENT GOOD GOOD EXCELLENT
Polyphenylene oxide (PPO) chlorinated 3
hydrocarbons
FAIR
Attacked by: acetone,
PVC (Polyvinyl- chloride) MEK, and methylene
GOOD FAIR EXCELLENT EXCELLENT EXCELLENT GOOD
chloride
FAIR
Attacked by:
Polyethylene chlorinated EXCELLENT EXCELLENT GOOD GOOD GOOD POOR
hydrocarbons3
POOR
Cycolac® ABS Attacked by: acetone,
MEK, esters, ketones, GOOD POOR GOOD GOOD GOOD FAIR
& some chlorinated
hydrocarbons
Glass5
EXCELLENT GOOD FAIR EXCELLENT GOOD GOOD EXCELLENT
Acrylic6
POOR FAIR POOR GOOD FAIR FAIR GOOD
Polysulfone FAIR
Attacked by: chlorinated FAIR POOR FAIR POOR POOR POOR
hydrocarbons3
Lexan® POOR GOOD FAIR POOR POOR POOR GOOD
Polycarbonate (see Lexan®, above)
NOTES:
Key to Performance NOTE 1: The control access cover of the OMNI-BEAM is Lexan® polycarbonate.
NOTE 2: ECONO-BEAM SE612CV, F, FP, LV, and all ac models have thermoplastic
Percent Retention polyester housings.
Rating to Strength Degree of Attack NOTE 3: Chlorinated hydrocarbons include Freon, methylene chloride, trichlorethane,
and trichloroethylene.
Excellent 85 to 100% Slight (or no) attack NOTE 4: Specials include LR/PT400SS and L16FSS.
Good 75 to 84% NOTE 5: Plastic lens covers are available for some sensors to meet FDA
Moderate attack requirements.
Fair 50 to 74% Noticeable swelling, NOTE 6: Glass covers are available for some sensors to protect the acrylic lens.
softening, etching, or
corrosion Lexan®, Cycolac® and NORYL® are registered trademarks of General Electric Co.
Poor <50% Severe degradation Delrin® is a registered trademark of Dupont Co.