You are on page 1of 2

DWG NO.

SH REV
ARV-HII-ELECT-005 1 XC
REVISIONS

NOTES: ZONE REV


ALL
ALL
XA
XB
DESCRIPTION
INITIAL RELEASE
CHANGED INVERTER CONFIGURATION PER DI REQUIREMENTS
DATE
01/25/12
03/09/12
APPROVED
SAS
SAS
SHT 1; PART LIST; PL #4 WAS QTY 12 NOW QTY 14, ADDED PL # 14. SHT 2; ZN 6D; REFDES
1 WIRING ROUTING AND INSTALLATION PER SAE-AS50881 AND TM 1-1500-323-24-1.
P191 WAS P48. ZN 6A; REFDES P192 WAS P49.
ALL STRANDED WIRE SHALL CONFORM TO SAE AS22759/34,/43 SPEC UNLESS OTHERWISE SPECIFIED. /43 IS PREFERRED, ALL XC 06/07/12 JES
SHT 2; ZN 4B; WIRE X19A20N WAS X13A20N. ZN 1B; ADDED SPLICE & 20 AWG JMPR. ZN 1A;
BUT 34 IS CONSIDERED ACCEPTABLE. ADDED SPLICE & 20 AWG JMPR
ALL SHIELDED WIRE SHALL CONFORM TO NEMA WC27500 SPEC USING STRANDED WIRE AS SPECIFIED ABOVE AND T23
OVER-JACKET.
UNLESS OTHERWISE NOTED, ALL WIRE TO BE 22AWG.
UNLESS OTHERWISE NOTED, JUMPERS SHALL NOT EXCEED 3" IN LENGTH.
LAST TWO DIGITS OF WIRE NUMBER DENOTES WIRE SIZE IN AWG.
BASIC SYMBOLOGY WILL BE AS FOLLOWS:
NEW WIRE/EQUIPMENT
EXISTING WIRE/EQUIPMENT
RELOCATED WIRE/EQUIPMENT
REMOVED WIRE
SINGLE SHIELDED WIRE \\\\\\\\\\\\\\\\\\\
TWO WIRE, TWISTED, SHIELDED
THREE WIRE, TWISTED, SHIELDED
W
B

W
B
O

2 WIRE NUMBERS TO BE PLACED ON OUTSIDE OF INSULATION AT INTERVALS NOT TO EXCEED 3 INCHES. HOT STAMPING
IS NOT PERMITTED.

3 CONNECTOR DESIGNATORS TO BE PERMANENTLY MARKED WITHIN 6" OF CONNECTORS.

4 CONNECTOR PINS DESIGNATED WITH AN UNDERLINED LETTER ARE LOWERCASE.

5 ALL BONDING AND GROUNDING SHALL BE IAW TM 1-1500-323-24-1 WP 017.

6 SOLDER CONNECTOR MS3106B18-9S INCLUDED WITH INVERTER.

7 CIRCUIT BREAKER TO BE NO MORE THE 8 INCHES FROM INVERTER OUTPUT.

PROPRIETARY NOTICE
THIS DRAWING CONTAINS DESIGNS AND
INFORMATION THAT ARE THE PROPERTY OF U.S. DEPARTMENT OF STATE
THE US DEPARTMENT OF STATE. EXCEPT FOR
RIGHTS EXPRESSLY GRANTED BY CONTRACT,
THIS DRAWING MAY NOT, IN WHOLE OR IN PART,
BE DUPLICATED OR DISCLOSED HEREIN, UH-1HII AV/ELEC UPGRADE
WITHOUT THE PRIOR PERMISSION OF THE US
DEPARTMENT OF STATE
INVERTER KGS ELECTRONICS
APPROVALS DATE
DRAFTER
M. LAVERTY 11/01/11 WIRING DIAGRAM
CHECKER
J. SMITH 01/20/12 SIZE CAGE CODE DRAWING NO. REV
DESIGNER
M. LAVERTY 11/01/11
D 1SMB2 ARV-HII-ELECT-005 XC
ITAR EXPORT CONTROLLED
LIMITED ACCESS
ANALYST

RELEASED
S. STARICK 01/25/12
SCALE:
NONE SHEET
1 OF 2
DWG NO. SH REV
ARV-HII-ELECT-005 2 XC

MAIN INVERTER
SPC-10(D)

OUTPUT

OUTPUT
ON/OFF
INPUT

GND
REMOTE

AC GND
115VAC

28VDC
28VDC

26VAC
P191 A B G C

X7A12N

X8A20N
X5A20

X6A20
7

2A
5

MAIN 115VAC
3
X2
10 4

7.5
13
7

MAIN 26VAC
3
X2 TRANSFER RELAY
MS24149-D1
K27
X6B20 A1 26 VAC BUS
INV PWR MAIN A2 X13A20 FUEL PRESSURE
X10B20 A3 3 1A E19A20 REF ARV-HII-ELECT-007
28 VDC 20A X1A12 11 E19B20
ESS X2 X3 2
INVERTER SWITCH B1 115 VAC /400 HZ BUS
X5B20
BUS 5 4
X2B20 B2 X14A20 AC FAIL RELAY
4 X2A20N 6 X15A20
X2C20 X9B20 B3 1A
INV PWR CONT 1
2 X3B20 X15B20
5A X3A20 3
7 11 X1 FUEL QTY
INV PWR SPARE X5 S39 1A E24A20 REF ARV-HII-ELECT-004
20A X4A12 4 X19A20N X2 3 2
X3 X2

7.5
6 9 3 8 11
X2 X2 13 X6

SPARE 26VAC
3 7
AC FAIL RELAY
X2 TYPE-D1
K8
10 4
P24, N REF V7A20 4

7 1
4
2A
5 X2
SPARE 115VAC

4 X17B20N 4
3
X2 X3 X18B18N 4
X1 14

X12A20N
X11A12N

20
X10A20
X9A20

X2 X16A20N 4 J3

C B W 1 12
6 X16B20 P3

20
P192 A B G C
14
115VAC
REMOTE
28VDC

26VAC

28VDC

AC GND

X18A18N
X15C20
X17A20
INPUT

ON/OFF

OUTPUT

OUTPUT

GND

4
M3

+
X2

-
SPARE INVERTER AC
SPC-10(D)
VOLTMETER
MS24332-1

SIZE CAGE CODE DRAWING NO. REV

D 1SMB2 ARV-HII-ELECT-005 XC
NONE
SCALE: SHEET
2 OF 2

You might also like