You are on page 1of 2

Member of the network

amda
Hellenic Technology Cluster Initiative
Ελληνική Πρωτοβουλία Τεχνολογικών
Συνεργατικών Σχηματισμών
in

electronics
no
va

m
Lift Control Cabinet ic s.co
ti o

n
tro
El ec
n

da
m
th

La
w.
at

DIOMEDES
w
lift
sy
ou
OPERATIONAL CHARACTERISTICS

Top speed 2m / sec


Stop accuracy <5mm
Supported lift types Traction V.V.V.F.
Hydraulic Traction
< 1.6 m/sec

Number of stations - Operation systems 16 (APB) – 8 (Down Collective)


8 (Up collective) – 6 (Full collective selective)
Display voltage +24 VDC
Display type BCD Decimal (Till 5 stops)
Pre open / Re level YES / YES
Voice announcer Serial communication. Programming ability from customer.
Number of doors 2
Supported door types ALL
Parameters / Timers 136 / 21

TECHNICAL CHARACTERISTICS STANDARDS


• Traction lift with V.V.V.F. drive using YASKAWA L1000A • EN 81.1
• Hydraulic lift with Δ – Υ/Δ – Soft Starter Drives • EN81 one contactor
• Traction 2 speed with thermal relay at both speeds • EN 81.2
• Safety circuit voltage +48 VDC • PUBEL (RUSSIA)
• Cars lights voltage 220 VAC • 95/16/ΕΚ
• Shaft lights voltage 220 VAC • 98/37/ΕΚ
• Emergency lights voltage +12 VDC • ΕΝ81.70 (DDA)
• Gong voltage +24 VDC • ΕΝ81.72 (FIRE FIGHTING)
• Cam voltage +110 VDC and + 48VDC • EN81.73 (EVACUATION)
• EN81.28 (EMERGENCY PHONES)
INNOVATIVE CHARACTERISTICS

1. The floor selector operates with 4 pencil magnetic 6. Specially designed module which offers the option for
switches for the hydraulic lift and 2 for the traction lift. No shaft lights operation to either use a push button and a
need for additional pencil magnetic switches for speed latch relay or a switch with allé retour connection.
change and evacuation.
7. Lamda Relay System modules which include the
2. Traction lift with V.V.V.F. drive using one contactor for following:
the motor by applying two base blocks (hardware and - Power supply with 48 VDC, 24 VDC
software) for maximum safety. and 12 VDC outputs.
- Car and door evacuation.
3. Evacuation on the traction lift with V.V.V.F. drive is - Revision.
executed without the requirement of additional PCB - Valve drive for hydraulic lifts.
boards.
8. Lamda Brake Release module for V.V.V.F. MRL driven
4. Specially designed modules for one or two door opera- lifts which includes the following:
tion without the need for any wiring alterations. - Safety Gear Short Circuit Button.
- Overspeed Governor Testing.
5. Specially designed modules for one or two CAMs with - Brake Release.
operating voltage of either 110VDC and/or 48VDC
without the need for any wiring alterations.