Corrosion Under Insulation – Root Causes and Effects, we have the Cure
i-Neema Ghana Ltd
Corrosion Under Insulation – Root Causes and Effects, we have the cure
Lobster backs
Low elevation
Water penetration into Insulation is the primary cause of CUI – if the water
can be prevented from entering the Insulation – CUI can be negated.
i-Neema Ghana Ltd
Corrosion Under Insulation – Root Causes
Corrosion Implications of Insulation Types
Type Water Extract Chloride
Calcium silicate alkaline (pH 7-10) possibly high
Fibre glass
Cellular glass
Ceramic fibre
Mineral wool neutral (pH 6-7) low (~2 mg/l)
Organic foams acid (pH 2-3) possibly high
- ASME PCC-2-2008
- ISO / TS 24817
c
i-Neema Ghana Ltd
Corrosion Under Insulation – Case Studies
Client : Exxon , Singapore
Equipment :
Fractionator Tower T102 operating at
120C
Problem :
Loss of wall thickness and unable to shut down the
process
Solution:
Manual preparation followed by repair and protective
coating with single component heat activated system
c
i-Neema Ghana Ltd
Corrosion Under Insulation – Case Studies
Equipment :
Gas Process pipe work operating at 90 – 115C
Problem :
Pitting corrosion and
unable to shut down the process
Solution:
Water Jetting preparation followed by repairs to
pitting and protective coating with and single
component heat activated system
c
i-Neema Ghana Ltd
ISO / TS 24817
c
i-Neema Ghana Ltd
Corrosion Under Insulation – i-Neema Solutions
ASME PCC-2 and ISO/TS 24817 allow for the repair of the
following: -
• Straight Pipe
• Complex Geometries, inc. bends, tees, reducers etc.
• Bulk Storage Tanks and Pressure Vessels
c
i-Neema Ghana Ltd
Repair Life
Code Compliant
repairs are designed
and calculated for
design lives of up to 20
years using standard
safety factors
c
i-Neema Ghana Ltd
Corrosion Under Insulation – Case Studies
Client : Statoil , Norway
Date : Year 2009
Equipment :
Production pipe work on Offshore
Platform
Problem :
Corrosion Under Insulation
Pitting and loss of wall thickness
Solution:
Preparation by Grit Blasting and compliant
Composite repair installed.
c
i-Neema Ghana Ltd
Corrosion Under Insulation – Case Studies
Client : Exxon , Norway
Date : Year 2009
Equipment :
Produced water process piping
Problem :
CUI resulting in perforations of
piping system
Solution:
Preparation by Grit Blasting and compliant
Composite repair installed.