You are on page 1of 5

ECG Project Name

Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


RAFTER ID :- ( R-1 ) Refrences
ECP
Steel grade St.37
Fy = 2.40 t/cm2
1)- APPLIED FORCES :- Case Fu = 3.60 t/cm2
M+ive = 11.19 mt a
N1 = 3.36 t
Q1 = 0.37 t
M-ive = 22.89 mt a
N2 = 3.47 t
Q2 = 5.22 t

2)- CHOISE OF SECTION :-


SECTION (1-1) :-
The section is Rolled section IPE 360
bFL = 170.0 mm
tFL = 12.7 mm
h = 360.0 mm
tWEB = 8.0 mm

SECTION (2-2) :-
bFL = 170.0 mm
tFL = 12.7 mm
h = 707.3 mm
tWEB = 8.0 mm

3)- RAFTER DATA :-


b
Total length of rafter (Lg) = 25.00 m
tfl
Purlin spacing (S) = 1.56 m
Bracing spacing (S') = 3.13 m b
tfl
tw
4)- CHECK SECTIONS :-
A)- Section (1-1) at M+ive :-
h tw
PROPERTIES OF SECTION :- h
Y = 18.00 cm
A = 72.70 cm2
Ix = 16270.00 cm4
Iy
Sx
=
=
1040.00
904.00
cm4
cm3
Sec (1-1)
rx = 15.00 cm

Sec (2-2)
ry = 3.79 cm

CHECK COMPACTNESS :-
dw/tw = 37.325 Web is Compact table(2.1a)
C/tf = 4.961 Flange is Compact table(2.1c)
The sec is Compact

CHECK NORMAL STRESSES :-


fbcx = 1.24 t/cm2 Cb = 1.000 table(2.2)
fca = 0.05 t/cm2
( 20.bf ) / (√ fy ) = 2.195 m ECP 16
Lumax = 2.195 m
( 1380.Af ) / ( fy.d ) x Cb = 3.45 m eqn. 2.18
ECG Project Name
Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


Lateral torsional buckling of comp.flange There is no LTB
ECG Project Name
Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


Fltb = 1.536 t/cm2
Fbcx = 1.536 t/cm2
Lbin = 17.50 m
Lbout = 3.13 m
lin = 116.67
lout = 82.45
lmax = 116.67 < 180 SAFE table(4.1)
Fc = 0.55 t/cm2
fca / Fc = 0.08
A1 = 1.00
Applying the interaction equation :
( fca / Fc ) + ( fbcx / Fbcx ) A1 = 0.890 < 1.00 SAFE eqn. 2.35

CHECK SHEAR STRESSES :-


qw = 0.22 t/cm2 < 0.840 SAFE eqn. 2.2

CHECK EQUIVALENT STRESSES :-


fe = 0.97 < 1.10 SAFE eqn. 2.39

B)- Section (2-2) at M-ive :-


PROPERTIES OF SECTION :-
Y = 35.37 cm
A = 122.07 cm2
Ix = 73220.75 cm4
Iy = 1561.50 cm4
Sx = 2070.43 cm3
rx = 24.49 cm
ry = 3.58 cm

Length of haunch = 2.50 m


Lu act.of comp. Flange from sap 1.56 m

CHECK COMPACTNESS :-
dw/tw = 37.325 Web is Compact table(2.1a)
C/tf = 4.961 Flange is Compact table(2.1c)
The sec is Compact

CHECK STRESSES :-
fbcx = 1.11 t/cm2
fca = 0.03 t/cm2
( 20.bf ) / (√ fy ) = 2.195 m ECP 16
Lumax = 1.755 m
( 1380.Af ) / ( fy.d ) x Cb = 1.76 m eqn. 2.18
Lateral torsional buckling of comp.flange There is no LTB
Fltb = 1.536 t/cm2 Use Knee Bracing yes
Fbcx = 1.536 t/cm2
Lbin = 16.25 m
Lbout = 1.56 m
lin = 66.35
lout = 43.69
lmax = 66.35 < 180 SAFE table(4.1)
Fc = 1.11 t/cm2
fca / Fc = 0.03
ECG Project Name
Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


A1 = 1.00
Applying the interaction equation :
( fca / Fc ) + ( fbcx / Fbcx ) A1 = 0.745 < 1.000 SAFE eqn. 2.35