You are on page 1of 3

# 10-3-282/D/1, Lane beside NEERU’s,

Humayun Nagar, Mehdipatnam, Hyderabad-28


+91-9885359660.Email:ermtinfo@gmail.com
GSTIN:-36ARJPM4584B1ZP

INTERNSHIPS TITLES

PLC
 Parking lot.
 Home Automation ( Tank level control ).
 Home Automation (Lighting control ).
 Sequential on & off of multiple loads.
 Counter, comparator & math based application of industry.
 Automation of forward reverse motor with interlock.
 Exit and parking area automation at the end of the day.
 Bottle filling application of conveyer belt.
 A single PB (NO ) is used to turn On and OFF the Motor.(Alternate presses and releases
turn On and OFF the motor)
 Automation for coordination of multiple conveyers
 Multiple conveyers packaging application automation.

SCADA / HMI
 Application to turn ON the output (light), when the input push button is pressed. Output
turns OFF when the same input push button is released.
 There are 3 switches and 3 lamps
o a)if switch 1 is closed, lamp 1 is ON
o b)if switch 2 is closed, lamp 1 and lamp 2 are ON
o c)if switch 3 is closed, all three lamps should be ON
 Application to turn ON the output (light), when the input push button-1 is pressed and
released. Output turns OFF when the input push button-2 is pressed and released.
 If any one Smoke sensor gives signal , nothing happens.
o If any two Smoke sensors give signal, warning light turns ON.
o If any 3 Smoke sensors give signal, Alarm starts.
o If all 4 Smoke sensors give signal, Fire extinguisher starts.
# 10-3-282/D/1, Lane beside NEERU’s,
Humayun Nagar, Mehdipatnam, Hyderabad-28
+91-9885359660.Email:ermtinfo@gmail.com
GSTIN:-36ARJPM4584B1ZP

 Basic Analog operations to show Rotation, Resizing, Colour blinking, Colour filling,
Visibility on-off, Horizontal movement, Vertical movement, Slanting movement and
Blinking .
 Application to show tank level control. The tank is fitted with a low level limit switch and a
high level limit switch.
o a)Pump motor turns ON when water level is at the bottom of tank.
o b) Pump motor turns off when water level is at the top of the tank
 If switch 1 closed, lamp A, turns ON. Lamp B turns on after 8 seconds. Both lamps turn
OFF, if switch 1 is opened.
 There are 3 motors and 1 input PB . When you press and release the input PB, motor 1
should turn ON, and turn OFF after 5 seconds. Motor 2 should turn ON when motor 1
turns OFF and it should turn OFF after 5 seconds. Motor 3 should turn on after motor 2
has turned OFF and it should turnoff after 5 seconds. Now motor 1 starts again and the
cycle repeats for 5 times after which all motors turn OFF.
 Parking area has a capacity of 10 vehicles. When parking area is empty, Entry gate is
open and exit gate is closed. When 1st vehicle enters, exit gate also opens. When 10
vehicles enter the parking area, then entry gate will be closed.
 There are two conveyer belts. One conveyer carries items and drops them 1 by 1 in the
basket on the second conveyer belt, which carries the basket for packing.When sensor
senses a basket, the basket conveyer should stop. Then items conveyer starts to fill 10
items in the basket. When 10 items are filled, items conveyer stops and basket conveyer
starts. This cycle repeats until the sensor has not sensed the basket for 20 seconds.
 Multifan Application.
 Batch Process application
 Trends, Alarms, Screen Navigation, Recipe and Security Application.

VFD
 Introduction to VFD
 Speed control of induction motor using VFD.
 Running an induction motor in different directions with different speeds
 Motor control with speed locks like LSP , HSP.
# 10-3-282/D/1, Lane beside NEERU’s,
Humayun Nagar, Mehdipatnam, Hyderabad-28
+91-9885359660.Email:ermtinfo@gmail.com
GSTIN:-36ARJPM4584B1ZP

AUTOCAD
 Designing of Electrical / Mechanical instruments
 Creating the layouts in multiple layers
 Electrical layouts power, lightning and ac
 HVAC layout designing.

ELECTRICAL DESIGN
 Overview of building services
 Basics of electrical engineering
 Electrical Switchgear, Busbar, Wires and Cables, Conduits, Transformers and
Generators Sizing
 Short Circuit Calculations
 Total Load calculation and Load Balancing in Buildings
 Electrical Designing of a Residential Complex
 Electrical Designing of a Commercial Complex
 Electrical Designing of Gated Community
 Automatic switching of motors with time delay
 Automatic turning off of devices
 Automatic and manual controlling of motors
 Interlocking technique between multiple motors
 Automatic direction changing in multiple motors
 Automatic star delta starter with over load protection.

You might also like