Figure 3: shows the control of Active and Figure 4: shows the simulation results of
Reactive power in the wind turbine. DFIG
Another example for the control structure As the doubly-fed induction generator speed
used for full-scale converter-based wind increases and the magnetic flux in the
turbine concept is shown in Fig 3. An generator is maintained at the optimal value,
advantage of this turbine system is that the
the active power at the stator remains constant. If the rotor of a doubly-fed
constant, while the active power at the rotor induction generator rotates in the opposite
decreases. Consequently, the generator total direction to the magnetic field created in the
power increases. Furthermore, when the rotor, the amplitude and frequency of the
generator speed reaches a certain value in voltages produced by the generator will be
Hyper-synchronous operation the rotor lower than during normal singly-fed
begins supplying active power the polarity operation at the same rotor speed. The
of active power at the rotor becomes frequency of the ac currents that need to be
negative which adds up to the active power fed into the doubly-fed induction generator
supplied by the stator. rotor windings so that the generator is
synchronized with the ac power network is
calculated below: