MATERIAL SPECIFICATON
1. SPECIFIED COMPRESSIVE STRENGTH OF REINFORCEMENT
K-225 kg/cm2
2. SPECIFIED YIELD STRENGTH OF REINFORCEMENT
Fy = 240 Mpa for Dia. < 12mm (PLAN BAR)
Fy = 390 Mpa for Dia. > 13mm (DEFORMED BAR)

ANALYSIS & DESIGN GUARANTEED BY

PT. SARMAG KONSULTAN NUSANTARA

MUHAMMAD AMMAR
PROJECT ENGINEERING MANAGER

PROJECT NAME

STANDAR PONDASI MCP DIA 350

SITE ID -
SITE NAME -

SITE ADDRESS -

AS PLAN DRAWING NAME

DETAIL FOUNDATION MCP

REVISE

NO DATE ITEM SIGNED

THIS DRAWING IS FULLY PROPERTIES OF


PT. TOWER BERSAMA GROUP AND CAN'T USED OR PRINTED
WITHOUT PERMISSION BY PT. TOWER BERSAMA GROUP

NAME DATE SIGNED

DRAWN

CHECKED

APPROVED

SHEET NO. TOTAL SHEET


ACKNOWLEDGE BY

PT. TELEKOMUNIKASI SELULAR

TOWER
BERSAMA
GROUP
ACKNOWLEDGE BY

TOWER BERSAMA GROUP

HASPRIYALDI
PROJECT INFRASTRUCTURE SUPPORT DEPT HEAD

IMPLEMENTATION BY

REMARK
MATERIAL SPECIFICATON
1. SPECIFIED COMPRESSIVE STRENGTH OF REINFORCEMENT
K-225 kg/cm2
2. SPECIFIED YIELD STRENGTH OF REINFORCEMENT
Fy = 240 Mpa for Dia. < 12mm (PLAN BAR)

BARBENDING SCHEDULE Fy = 390 Mpa for Dia. > 13mm (DEFORMED BAR)

ANALYSIS & DESIGN GUARANTEED BY

Description Measure Concrete


PT. SARMAG KONSULTAN NUSANTARA

Length Qty Weight


a b c Dia. Volume
MUHAMMAD AMMAR
PROJECT ENGINEERING MANAGER

m m m mm m pcs kg m3 PROJECT NAME

STANDAR PONDASI MCP DIA 350


a SITE ID -
LONGITUDINAL b 4.100 0.640 0.00 16 4.740 50 374.460 SITE NAME -

SITE ADDRESS -
3.297 AS PLAN DRAWING NAME

STIRRUP-1 0.900 0.00 0.00 10 2.826 28 49.059


a

DETAIL ANCHOR AND BARBENDING

REVISE

Total 423.519 3.297 NO DATE ITEM SIGNED

THIS DRAWING IS FULLY PROPERTIES OF


PT. TOWER BERSAMA GROUP AND CAN'T USED OR PRINTED
WITHOUT PERMISSION BY PT. TOWER BERSAMA GROUP