You are on page 1of 11

Hilti PROFIS Engineering 3.0.

61

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: bkt N6 Date: 6/18/2020
Fastening point:

Specifier's comments:

1 Input data
Anchor type and diameter: HST3-R M12 hef2
Return period (service life in years): 50
Item number: 2105870 HST3-R M12x115 40/20
Filling set or any suitable annular gap filling solution
Effective embedment depth: hef = 70.0 mm, hnom = 80.0 mm
Material: A4
Evaluation Service Report: ETA-98/0001
Issued I Valid: 10/2/2019 | -
Proof: SOFA design method + fib (07/2011) - after ETAG testing
Stand-off installation: eb = 0.0 mm (no stand-off); t = 12.0 mm

Anchor plate :
R lx x ly x t = 350.0 mm x 235.0 mm x 12.0 mm; (Recommended plate thickness: 9.0 mm)

Profile: Double flat bar, ; (L x W x T) = 72.0 mm x 35.0 mm x 5.0 mm


Base material: cracked concrete, C40/50, fc,cyl = 40.00 N/mm ; h = 230.0 mm
2

Installation: hammer drilled hole, Installation condition: Dry


Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

R
- The anchor calculation is based on a rigid anchor plate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.61

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: bkt N6 Date: 6/18/2020
Fastening point:

1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 Combination 1 N = 0.000; Vx = 0.000; Vy = 4.300; no no 85
Mx = -0.430; My = 0.000; Mz = 0.000;

2 Combination 2 N = 0.000; Vx = 0.000; Vy = -4.300; no no 72


Mx = 0.430; My = 0.000; Mz = 0.000;

2 Load case/Resulting anchor forces


Controlling load case: 1 Combination 1
y

Anchor reactions [kN]


Tension force: (+Tension, -Compression) Compression
Anchor Tension force Shear force Shear force x Shear force y x
1 1.575 11.288 0.000 -11.288
2 1.731 15.588 0.000 15.588
1 2
max. concrete compressive strain: 0.05 [‰] Tension
max. concrete compressive stress: 1.62 [N/mm ]
2

resulting tension force in (x/y)=(-98.1/-67.5): 3.306 [kN]


resulting compression force in (x/y)=(-98.1/62.6): 3.306 [kN]

Anchor forces are calculated based on the assumption of a rigid anchor plate.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.61

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: bkt N6 Date: 6/18/2020
Fastening point:

3 Tension load SOFA (fib (07/2011), section 10.1)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 1.731 30.357 6 OK
Pullout Strength* 1.731 18.856 10 OK
Concrete Breakout Failure** 3.306 25.795 13 OK
Splitting failure** N/A N/A N/A N/A

* highest loaded anchor **anchor group (anchors in tension)

3.1 Steel Strength

NRk,s [kN] gM,s NRd,s [kN] NSd [kN]


42.500 1.400 30.357 1.731

3.2 Pullout Strength

NRk,p [kN] yc g M,p NRd,p [kN] NSd [kN]


20.000 1.414 1.500 18.856 1.731

3.3 Concrete Breakout Failure


0 2
Ac,N [mm ]
2
Ac,N [mm ] y A,N ccr,N [mm] scr,N [mm]
60,900 44,100 1.381 105.0 210.0

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N


1.9 0.982 0.0 1.000 1.000 1.000
0
k1 NRk,c [kN] gM,c NRd,c [kN] NSd [kN]
7.700 28.521 1.500 25.795 3.306

Group anchor ID
1, 2

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.61

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: bkt N6 Date: 6/18/2020
Fastening point:

4 Shear load SOFA (fib (07/2011), section 10.2)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 15.588 29.360 54 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength* 15.588 36.498 43 OK
Concrete edge failure in direction y+** 15.588 18.356 85 OK

* highest loaded anchor **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)

VRk,s [kN] gM,s VRd,s [kN] VSd [kN]


36.700 1.250 29.360 15.588

4.2 Pryout Strength


0 2
Ac,N [mm ]
2
Ac,N [mm ] y A,N ccr,N [mm] scr,N [mm] k4
30,450 44,100 0.690 105.0 210.0 2.780

ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N


0.0 1.000 0.0 1.000 1.000 1.000
0
NRk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
28.521 1.500 36.498 15.588

Group anchor ID
1, 2

4.3 Concrete edge failure in direction y+

lf [mm] dnom [mm] kV a b


70.0 12.00 1.700 0.071 0.061
0 2
c1 [mm] Ac,V [mm ]
2
Ac,V [mm ] y A,V
140.0 105,000 88,200 1.190

y s,V y h,V y a,V ec,V [mm] y ec,V y re,V y 90°,V


1.000 1.000 1.000 40.0 0.840 1.000 2.000
0
VRk,c [kN] gM,c VRd,c [kN] VSd [kN]
27.534 1.500 18.356 15.588

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.61

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: bkt N6 Date: 6/18/2020
Fastening point:

5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
bN bV a Utilization bN,V [%] Status
steel 0.057 0.531 2.000 29 OK
concrete 0.128 0.849 1.500 83 OK

a a
bN + bV <= 1

6 Displacements (highest loaded anchor)


Short term loading:

NSk = 1.282 [kN] dN = 0.1080 [mm]


VSk = 11.546 [kN] dV = 1.8144 [mm]
dNV = 1.8176 [mm]
Long term loading:

NSk = 1.282 [kN] dN = 0.2160 [mm]


VSk = 11.546 [kN] dV = 2.6941 [mm]
dNV = 2.7028 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

7 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2018, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient compressive strength (e.g. by using the Hilti Filling set) or by other suitable means
• The compliance with current standards (e.g. EN 1993, AS 4100:1998, etc.) is the responsibility of the user
• The anchor plate overlaps the concrete plate edges. A local concrete spalling due to compression has to be checked separately!
• Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!
• The characteristic bond resistances depend on the return period (service life in years): 50

Fastening meets the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.61

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: bkt N6 Date: 6/18/2020
Fastening point:

8 Anchor plate stress check


Scope: For the loads / load combinations applied on the anchor plate, an anchor plate stress check is performed (based on the results of a
FE calculation). This stress check contains normal stresses resulting from bending moments in two directions. The user is responsible to
select an anchor plate thickness that meets the requirement per guideline for a rigid anchor plate (to ensure that the assumed load distribution
(1)
is correct). A detailed description can be found in Mallée.

(1)
Mallée, R.; Riemann, H. (1990): Ankerplattenbefestigungen mit Hinterschnittdübeln,
Bauingenieur 65 (1990), S. 49 - 57, Springer VDI-Verlag, 1990
Mallée, R.; Burkhardt, F. (1999): Befestigungen von Ankerplatten mit Dübeln, Beton und
Stahlbetonbau 94, Heft 12, S. 502 - 511, Ernst & Sohn Verlag, 1999

8.1 Base material properties

Steel type: S 275


2
Yield stress: fy = 275.00 [N/mm ]
Partial safety factor: gm,s = 1.000
2
Ultimate strength: fu = 430.00 [N/mm ]
2
Young's modulus: Es = 210,000.00 [N/mm ]
Poisson ratio: n = 0.3

8.2 Results

Relevant load combination: LC 01

Stress distribution s 11
2
127.58 [N/mm ]

2
-53.79 [N/mm ]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.61

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: bkt N6 Date: 6/18/2020
Fastening point:

Stress distribution s 22
2
44.14 [N/mm ]

2
-154.48 [N/mm ]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.61

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: bkt N6 Date: 6/18/2020
Fastening point:

Deformations (z-direction)
1.4 [mm]

-0.6 [mm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.61

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: bkt N6 Date: 6/18/2020
Fastening point:

9 Installation data
2 2
Anchor plate, steel: S 275; E = 210,000.00 N/mm ; fyk = 275.00 N/mm Anchor type and diameter: HST3-R M12 hef2
Profile: Double flat bar, ; (L x W x T) = 72.0 mm x 35.0 mm x 5.0 mm Item number: 2105870 HST3-R M12x115 40/20
Hole diameter in the fixture: df = 14.0 mm Installation torque: 60 Nm
Plate thickness (input): 12.0 mm Hole diameter in the base material: 12.0 mm
Recommended plate thickness: 9.0 mm Hole depth in the base material: 88.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 140.0 mm
Cleaning: Manual cleaning of the drilled hole according to instructions for use is
required.

Hilti HST3 stud anchor with 80 mm embedment, M12 hef2, Stainless steel, installation per ETA-98/0001, with annular gaps filled with Hilti
Filling set or any suitable gap solutions

9.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • Hilti SIW 6AT-A22 + SI AT-A22
• Properly sized drill bit • Filling set
• Torque wrench
• Hammer

150.0
y
175.0 175.0

117.5
77.0

185.0

x
117.5

1 2
50.0

35.0 80.0 235.0

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -140.0 -67.5 - - - 140.0
2 -60.0 -67.5 - - - 140.0

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

9
Hilti PROFIS Engineering 3.0.61

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: bkt N6 Date: 6/18/2020
Fastening point:

10 Drilling and installation

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

10
Hilti PROFIS Engineering 3.0.61

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/middle-east.html
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: bkt N6 Date: 6/18/2020
Fastening point:

11 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2020 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

11