Structural Engineers:

Ysrael A. Seinuk, PC
228 East 45th Street, 2nd Floor 270 Lafayette Street, Suite 905
New York, NY 10017 New York, NY 10012
Telephone: (212) 687-2233 t 212 . 343 . 0044

LEGEND EXIT STAIR EGRESS ANALYSIS FOR 3RD FLOOR - PHASE 2

STAIR WIDTH ENTRY TO STAIR DOORS


STAIR # REMARKS
PERSONS PER PERSONS PER
WIDTH E.U. E.U. EXIT CAPACITY WIDTH E.U. E.U. EXIT CAPACITY

A 48"W 2 60 120 (2) 36"W 3 80 240 NEW DOORS INSTALLED DURING PHASE 1

B (2) 48"W 4 0 0 (4) 33"W 6 0 0 BLOCKED DURING PHASE 2

C (2) 48"W 4 60 240 (4) 33"W 6 80 480

D 48"W 2 60 120 (2) 37"W 3 80 240

3RD FLOOR STAIR WIDTH 1023 3RD FLOOR STAIR DOOR 1023
CAPACITY REQUIRED PERSONS CAPACITY REQUIRED PERSONS

3RD FLOOR STAIR WIDTH 480 2ND FLOOR STAIR DOOR 960
CAPACITY PROVIDED PERSONS CAPACITY PROVIDED PERSONS

INSUFFICENT STAIR CAPACITY PROVIDED INSUFFICENT DOOR CAPACITY PROVIDED