C1.Design stipulation:
i Characteristic Compressive strength = 25 N/mm2
ii Maximum size of aggregate = 20 mm
iii Degree of workability = 0.8
iv Degree of quality = Good
v Type of Exposure = Mild
1 Cement 422.73 kg
2 Fine Aggregate 565.72 kg
3 Coarse Aggregate 20mm 709.71 kg
4 Coarse Aggregate 10mm 473.14 kg
5 Water 183.63 ltr
6 Slump 75 - 100 mm
7 W/C ratio 0.44
Prepared by,
Sathiyaseelan
+91 8894770272
Concrete Mix Design
1) Design Grade = 25
2) Target Mean Strength = 31.56
w/c=0.60
Nominal max. Water
Size of aggregate Content Sand Content
10 208 40
20 186 35
40 165 30
Adjusted Required in
Change in Condition % of Sand
Water Content
Content
For Sand Cofirming Zone 1
to grading zone- I, 0 zone 3 -3
II, or IV of IS : 383-1970 Zone 4
Increase in
Compaction 3 W/C
Factor Ratio
0.3
0.35
Each 0.05 increase or 0.4
Decrease in free w/c -2.4
ratio(std=0.60) 0.45
0.5
Total 3 -540.00% 0.55
0.6
6.488 0.3
18.644
12.16 0.35
0.4
Axis Title
0.45
0.5
0.55
0.3
0.35
0.4
Axis Title
0.45
10.38
19.68 0.5
9.30
0.55
0.6
980
126.706349206349
3.37837837837838 1/(1-P) 1.4204545
0.377358490566038 1/Sc 0.3257329