You are on page 1of 3

FRAME 1014H WINDING M

MODELS LB1014H(X) (inc LLB / LUB / LFB) REF: F1004HWM-2 APRIL 2010

WINDING DETAILS MECHANICAL DETAILS


Code M Insulation class H Standard protection IP23
Phase 1 Leads 4 Overspeed rpm 2250
Pole number 4 Pitch 2/3 Air flow 50Hz/60Hz m3/s 0.15 / 0.18

EXCITATION DETAILS WAVEFORM


Excitation system SHUNT No load or linear rated load
AVR model R250 Total harmonic content THC <4%
Sustained short-circuit current - Telephone influence factor TIF (NEMA) <50
Steady state voltage regulation ±0.5% Telephone harmonic factor THF (IEC) <2%

VOLTAGE
Frequency / speed 50Hz / 1500rpm 60Hz / 1800rpm
Series V 220 230 240 220 230 240
Parallel V 110 115 120 110 115 120

1 2 3 4 6 7 8 9 10 11
RATING Power factor 1.0, Altitude <=1000m
Class H rise BR 125/40 kVA 12.0 12.0 12.0 13.0 13.0 13.0
kW 12.0 12.0 12.0 13.0 13.0 13.0
Class H rise PR 150/40 kVA 12.7 12.7 12.7 13.8 13.8 13.8
kW 12.7 12.7 12.7 13.8 13.8 13.8
Class H rise PR 163/27 kVA 14.0 14.0 14.0 14.5 14.5 14.5
kW 14.0 14.0 14.0 14.5 14.5 14.5
Class F rise BR 105/40 kVA 10.9 10.9 10.9 11.8 11.8 11.8
kW 10.9 10.9 10.9 11.8 11.8 11.8

EFFICIENCIES Power factor 1.0


110% Class H BR % 79.8 80.7 81.4 79.4 80.6 81.6
100% Class H BR % 81.7 82.5 83.0 80.8 81.9 82.8
75% Class H BR % 84.5 85.0 85.3 83.8 84.6 85.3
50% Class H BR % 86.8 86.9 86.8 86.4 86.9 87.2
25% Class H BR % 86.4 85.9 85.0 86.6 86.5 86.4

CHARACTERISTIC PARAMETERS Reactance base class H BR rating


Kc Short-circuit ratio 0.46 0.55 0.65 0.30 0.32 0.39
Xd D-Axis synchronous reactance (unsaturated) pu 1.74 1.59 1.46 2.26 2.06 1.90
X'd D-Axis transient reactance (saturated) pu 0.32 0.29 0.27 0.42 0.38 0.35
X''d D-Axis sub-transient reactance (saturated) pu 0.156 0.143 0.131 0.203 0.186 0.171
Xq Q-Axis synchronous reactance (unsaturated) pu 0.87 0.79 0.73 1.13 1.03 0.95
X''q Q-Axis sub-transient reactance (saturated) pu 0.223 0.204 0.188 0.290 0.265 0.244
X2 Negative-sequence reactance (saturated) pu - - - - - -
X0 Zero-sequence reactance (independent) pu - - - - - -
T'd D-Axis transient time constant ms 40 40
T''d D-Axis sub-transient time constant ms 6 6
T'do D-Axis open-circuit time constant ms 280 280
Ta Armature time constant ms 8 8
Tr Voltage recovery time ms < 500 < 500

EXCITATION VOLTAGE AND CURRENT

No load excitation voltage V 13.2 14.4 16.0 9.4 9.9 10.6


No load excitation current A 0.56 0.61 0.68 0.40 0.42 0.45
Class H BR excitation voltage V 32.3 32.6 33.5 30.2 29.3 28.6
Class H BR excitation current A 1.37 1.38 1.42 1.28 1.24 1.21

WINDING RESISTANCE At 20 o C
Stator (series) Ω 0.330 Exciter field Ω 23.6
Main field Ω 2.06

According to: IEC 60034, UTE NFC51.111, VDE 0530, BS 4999/5000, NEMA MG 1-33
Values quoted are typical. In line with our policy of continuous improvement, we reserve the right to change specification without notice.
FRAME 1014H WINDING M

MODELS LB1014H(X) (inc LLB / LUB / LFB) REF: F1004HWM-2 APRIL 2010

LOCKED ROTOR MOTOR STARTING CURVES Power factor 0.9

50 Hz SHUNT

220V

230V

240V
35

30

25
voltage dip %

20

15

10

0
0 5 10 15 20
kVA

60 Hz SHUNT
220V

230V

240V

35

30

25
voltage dip %

20

15

10

0
0 5 10 15 20
kVA

According to: IEC 60034, UTE NFC51.111, VDE 0530, BS 4999/5000, NEMA MG 1-33
Values quoted are typical. In line with our policy of continuous improvement, we reserve the right to change specification without notice.
FRAME 1014H WINDING M

MODELS LB1014H(X) (inc LLB / LUB / LFB) REF: F1004HWM-2 APRIL 2010

SHORT-CIRCUIT DECREMENT CURVES No-load excitation at rated speed

230V 50Hz Series

1000
asymmetrical
RMS current (A)

symmetrical

100

10
1 10 100 1000 10000
time (ms)

Multiplication Factors

50Hz Voltages 220 230 240

Multiplication Factor 0.96 1.00 1.04

Apply factor up to 2xT'd, remainder of curve unchanged

60Hz Voltages 220 230 240

Multiplication Factor 0.80 0.83 0.87

Apply factor up to 2xT'd, remainder of curve unchanged

Winding Connection Series Parallel

Multiplication Factor 1.00 2.00

Apply factor to the complete curve

According to: IEC 60034, UTE NFC51.111, VDE 0530, BS 4999/5000, NEMA MG 1-33
Values quoted are typical. In line with our policy of continuous improvement, we reserve the right to change specification without notice.