Professional Documents
Culture Documents
U U
OL L1 1 2
R L2 F
3x400VAC
5 6 1 2 V M2
~
M
S
3
T L3 U 3 4 W
F Fast Speed
D
D 1 2
Option X D
N F1/F2/F3 S
5 6 1 2 Y M1
~
C3x2A
M
L1/R U
3
D 3 4 Z
PE L2/S V
S Slow Speed
G T2 L3/T W Option 230VAC
T 15 SOFT START L1
S2 N
R2 S NV -
Thermistor Option R 18 F1
21 22
230VAC BG2 S F10 /2A
R2 A1 T1 T1 53 54
TPR F1
N A2 T2 T2 + 1 2
. 18V
95
96
6
F5 /B6A F1
24V 4 3 L
5
C F1 C
5 6
400V
F4 /C4A
22/18
4
D 3 5
S 6
BR Motor Brake
F7/8/9
3x1.5A
* 6A In case of retiring cam
G B2
3x400V For 3 Phase Door Motor
O dm1
OLD 1 2
B L1 dm2 B
L2 3 4
~
M
L3
3
5 6 dm3
O Door Motor
G
F6-C6A 1
C 2
LS 4 L
1 LO
230VAC P L L LOH
LR 3 4
Car Light 0 N N Fan Sw.
5 6
LSH C C=0.33mF/600V
R=470R/1W
Automatic
Insp. Light Car Fan
Car Light
OZ
A A
PHOTO CELL
Permanent Safeties
NO Volt and
sequence
Up
L.Sw
D.L.Sw. Pit Sw
SOS STOP
CIPB= COMMON . C6
F3A /2A C1 C2 C3
15 18 PHC CAR DOOR CONTACT INTERLOCKS
+60vDC GC C32 ICS
C19
NV ITS .
BSDS
Bottom
Identification and .
C21
G
NORMAL
INSPECTION
NSR
. RSN= COMMON HALL CALLS
slow down
TSDS
Top Identification and
slow down
. C22 UIPB- INSP UP
2C
.
IND-1 .
1C
C
Slow Down Inductor .
C61 DIPB- INSP. DN
C
IND-2
Stopping Inductor .
C4 C1
(C6) IN CASE OF MANUAL DOORS
C19
.
CFM C7
C93 DOL
CAR . DSE OPEN L. SW.
FIREFIGHTER
HFM C94
Safety Edge . ROD
. DCL
DOOR
CLOSE
LIMIT SW
FAST D.
LIMIT SW.
FAST UP
L. SW.
HALL FDLS FULS
FIREFIGHTER . DOB
C18
FULL LOAD
FLS
FL
.
Open Door
p.Button . OD
C14 C8 51
F
52 C9
OLS
B
G Over Load . SOL
2 A1 A1 A1 A1 A1 A1
B
LIGHT RELAY
L O C S F D U
A2 A2 A2
CONTACTORS TH U D F S 10 A2 A2 A2
62
22
22
Interlock
C O S
60 o BIMETAL
61
21
21
(LC) (O) (C) (S) (F) (D) (U)
UML-21LV CAR LIGHT OPEN DOOR CLOSE DOOR SLOW FAST DOWN UP
A A
C SW - 2 A C
FLOOR
DIP No 1 - ON 0 - OFF UML-21LV Master Card
No 1 2 3 4 5 7 8 1C 2C 3C 4C 5C 6C 7C 8C
DIS - 1 : Failurs List 2 1 0 0 0 0 0 0
a 3 0 1 0 0
1C 2C 3C 4C 5C 6C 7C 8C A.P.B
First Traveling Timer = a /1
4 1 1 0 0 1 0 0 1C 2C 3C 4C 5C 6C 7C 8C A.P.B + Car Collective calls
Second Traveling Timer = b /1
5 0 0 1 0
Interlock = c /1 f b 0 0 1
Hall Firefighter Key g 6 1 0 1 0 1C 2C 3C 4C 5C 6C 7C 8C Down Collective (Regular)
= d /1
Contactor Doesn't relised 7 0 1 1 0
= e /1 1 0 1 1C 2C 3C 4C 5C 6C 7C 8C Full Collective
Open limit Sw. e c 8 1 1 1 0
= f /1
9 0 0 0 1
B B
14-E 1 0 1 1
0 1 0 1C 2C 3C 1D 2D 3D LC BM 3 Floors Down Collective
15-F 0 1 1 1
A A
2 Inductors System Magnets & Shaft Switches One Inductors System Magnets & Shaft Switches
C4 C61 C61
E
Up Limit Switch FSL1 Up Limit Switch FSL1 E
D D
C C
Down Slow Down Switch BSDS=C21 Down Slow Down Switch BSDS=C21
Up Slow Down Point Up Slow Down Point
Fast Down Limit Switch FDLS Fast Down Limit Switch FDLS
The Minimum size of I1 and I2 =100mm. The Minimum size of I1 for counting is =100mm.
For The stopping size between the magnets is about 150mm.
A
APP. NAME : Benci Magnets and Shaft switces A
Title
APP. DATE :
En_UML-21LV SHAFT MAGNETS AND SW.
Size Document Number Rev
E E
B E
13c-16c
9u-15u
13d-16d
0 0
9d-12d
0
9c-12c
1du-8d
2u-8u
D
0 0 D
18V
18V
C
. C
.
8C .8D
.
7C .7D .7U
.
3U
.2C .2D .
2U
B
.
1C .
1DU B
UP
CAR DOWN CALLS
CALLS CALLS
NSR
.G
A
APP. NAME : Benci A
Title
APP. DATE : UML-21LV_CARDS ADDRESSES
CARD TERMINAL . Size Document Number Rev