The document summarizes the dimensions and reinforcement details of four combined footings (CF1-CF4). Each combined footing supports two columns and has a uniform depth between 0.35-0.37 meters. The reinforcement consists of 16mm deformed bars spaced at 120mm in both directions near the top and bottom of the footing. The distance between columns is consistently 1.55 meters.
The document summarizes the dimensions and reinforcement details of four combined footings (CF1-CF4). Each combined footing supports two columns and has a uniform depth between 0.35-0.37 meters. The reinforcement consists of 16mm deformed bars spaced at 120mm in both directions near the top and bottom of the footing. The distance between columns is consistently 1.55 meters.
The document summarizes the dimensions and reinforcement details of four combined footings (CF1-CF4). Each combined footing supports two columns and has a uniform depth between 0.35-0.37 meters. The reinforcement consists of 16mm deformed bars spaced at 120mm in both directions near the top and bottom of the footing. The distance between columns is consistently 1.55 meters.
a b c1 d1 c2 d2 2.27 m 0.67 m 0.40 m 0.35 m 0.30 m 0.30 m H = 0.37 m (total depth of the footing), d = 0.33 m (effective depth of reinf.) Use 16 mm deformed bars @ 120 mm spacing in the long and short direction top and bottom 1.55 m between columns
CF2 Column 1 Column 2
a b c1 d1 c2 d2 2.14 m 0.70 m 0.30 m 0.30 m 0.40 m 0.35 m H = 0.35 m (total depth of the footing), d = 0.31 m (effective of reinf.) Use 16 mm deformed bars @ 120 mm spacing in the long and short direction top and bottom 1.55 m between columns CF3 Column 1 Column 2 a b c1 d1 c2 d2 2.14 m 0.70 m 0.40 m 0.35 m 0.30 m 0.30 m H = 0.35 m (total depth of the footing), d = 0.31 m (effective of reinf.) Use 16 mm deformed bars @ 120 mm spacing in the long and short direction top and bottom 1.55 m between columns
CF4 Column 1 Column 2
a b c1 d1 c2 d2 2.14 m 0.70 m 0.30 m 0.30 m 0.40 m 0.35 m H = 0.37 m (total depth of the footing), d = 0.33 m (effective of reinf.) Use 16 mm deformed bars @ 120 mm spacing in the long and short direction top and bottom 1.55 m between columns