Summary of Combined Footing:

CF1 Column 1 Column 2


a b c1 d1 c2 d2
2.27 m 0.67 m 0.40 m 0.35 m 0.30 m 0.30 m
H = 0.37 m (total depth of the footing), d = 0.33 m (effective depth of reinf.)
Use 16 mm deformed bars @ 120 mm spacing in the long and short direction top and
bottom
1.55 m between columns

CF2 Column 1 Column 2


a b c1 d1 c2 d2
2.14 m 0.70 m 0.30 m 0.30 m 0.40 m 0.35 m
H = 0.35 m (total depth of the footing), d = 0.31 m (effective of reinf.)
Use 16 mm deformed bars @ 120 mm spacing in the long and short direction top and
bottom
1.55 m between columns
CF3 Column 1 Column 2
a b c1 d1 c2 d2
2.14 m 0.70 m 0.40 m 0.35 m 0.30 m 0.30 m
H = 0.35 m (total depth of the footing), d = 0.31 m (effective of reinf.)
Use 16 mm deformed bars @ 120 mm spacing in the long and short direction top and
bottom
1.55 m between columns

CF4 Column 1 Column 2


a b c1 d1 c2 d2
2.14 m 0.70 m 0.30 m 0.30 m 0.40 m 0.35 m
H = 0.37 m (total depth of the footing), d = 0.33 m (effective of reinf.)
Use 16 mm deformed bars @ 120 mm spacing in the long and short direction top and
bottom
1.55 m between columns