You are on page 1of 1

DESIGN OF SIDE WALL

SUPPORT - HOGGING
Depth of member at mid span (D) = 450 mm
Width of the member (b) = 1000 mm

MATERIAL PROPERTIES :
Grade of concrete, fck = 35 MPa PERMISSIBLE STRESSES
Mean value of concrete compressive strength, fcm = 45 MPa 1) Permissble concrete compressive stresses
Grade of Reinforcement = 500 MPa Load Combination Permissble Stress
fywd 0.8 fyk = 400 MPa SLS Rare 0.48 fck = 16.8 MPa
Clear cover to the earth face of side wall = 75 mm SLS QP 0.36 fck = 12.6 MPa
Modulus of Elasticity steel Es = 200000 MPa
For short Term loading Ecm = 32308 MPa
For long Term loading Ecm' = 12665 MPa SLS Rare 0.6 fy = 300 MPa
fctm = 2.80 MPa 2) Permissble Tensile stress in steel SLS QP 0.6 fy = 300 MPa
fcteff = Max of 2.9 Mpa or fctm = 2.90 MPa 3) Permissible crack width wk
fcd = 15.75 MPa SLS QP Load combination = 0.3 mm
Cross sectional Area, Ac = 0.675 m2
Perimeter in contact with atmosphere u = 3.90 m Maximum Reinforcement
Notational size ho = 346.15 mm [ Tension Reinf. ] ≤ 0.025AC At section other than Laps
Age of concrete at the time of loading = 90 days [ Tension + Compression ] ≤ 0.04AC At any section
t∞ considered = 25550 days Where AC = Gross Cross section Area of Concrete
Creep factor Φ = 1.551
εuk = 0.00250 Minimum Reinforcement :
εud = 0.00225 Ast min = Max [ 0.26 fctm / fyk bt d , 0.0013 bt d ] (Refer IRC:112 clause 16.5.1.1)
εcu2 = 0.0035 bt = Mean width of Tension zone.
xumax/d = 0.6087

A) ULS CAPACITY CHECK (Side Wall Hogging)


Check Check Check
xu = 0.87 fyk Ast /

MRd =0.87 fyk Ast


fyk (d'-0.416 xu)
Ast,cal =M/ 0.87
Distance Area of steel provided

Ast,provided > Ast

MRD/z > MED/z +


(d-0.416 xu)
from

Provided < Ast


0.362 fck b

Ast Calc. < Ast


Ast Max
Section centreline of

Ast min
side wall (m) MED Overall Ast, z = d-
(Hogging) b depth D d Dia Spacing Provided xmax Check ∆Fd 0.416 xu MED/z +∆Fd MRD/z

Max

min

∆Fd
kNm mm mm mm mm mm mm2 mm mm mm2 mm2 mm2 kN m kN kNm kNm/m

Face of Support 0.225 68 1000 600 517 16 200 1571 315 54 UR, OK 318 27000 OK 753 OK 43 495 181 338 683 OK
12 200
Haunch End 0.375 60 1000 450 367 16 200 1571 223 54 UR, OK 402 27000 OK 534 OK 35 345 210 235 683 OK

12 200
deffective 0.592 53 1000 450 367 16 200 1571 223 54 UR, OK 355 27000 OK 534 OK 25 345 179 235 683 OK
12 200
Curtailment 0.675 52 1000 450 367 16 200 1005 223 35 UR, OK 336 27000 OK 534 OK 20 353 167 154 437 OK
0 200
Mid Span 0.963 48 1000 450 367 16 200 1005 223 35 UR, OK 314 27000 OK 534 OK 7 353 143 154 437 OK
0 200

28