TUTORIAL SHEET 3
Note: Make suitable assumptions wherever necessary
• The following test results are obtained for a 20kVA, 50Hz, 2400/240V distribution
transformer
(a) When the transformer is operated as a step down transformer with the output
voltage to 240V, supplying a load at unity PF, determine the maximum efficiency and
the unity UPF load at which it occurs.
• In a 25kVA, 2000/200V transformer, the iron and copper losses are 300 and 400W
respectively. Calculate the efficiency on unity power factor at (i)full-load (ii)half-load.
Also determine the load for maximum efficiency and the iron and copper loss in that
case.
Calculate the load KVA at which the transformer efficiency would be maximum for a
given power factor. Calculate this maximum efficiency for a pf of 0.85.
• If a third transformer is added to complete the ∆, find the percentage increase in the
real power that can be supplied assuming the load voltage and power factor remaining
unchanged.
• Three 1ϕ, 10kVA, 460/120V, 60Hz transformers are connected to form a 3ϕ, 460/208V
transformer bank. The equivalent impedance of each transformer referred to HV side is
1+j2Ω. The transformer delivers 20kW at 0.8 pf leading. Draw the schematic showing
1
the transformer connection. Determine the currents flowing through the primary and
secondary of all three transformers. Also determine the voltage regulation.