You are on page 1of 55

Civil, Plumbing, Electrical, Fire Fighting, Auxiliary and Site Development,

Infrastructure & allied works for Aga Khan Academy, Hyderabad.


2-Dec-09
SUMMARY

Sr. No. Description Total Amount (Indian Rupees)

Section A

1 Civil Works #REF!

2 Plumbing Works 7 67 44 481

3 Electrical Works 16 49 02 951

4 IBMS Works 6 32 16 724

5 Fire Fighting Works 67 15 674

Total Amount for Section A #REF!

Labour Welfare Cess @ 1% #REF!

Total Amount for Section A inc Labour Cess #REF!

Section B: Provisional Items

6 Doors and Windows 7 56 80 940

7 HVAC Works 6 41 77 500

8 False Ceiling Works 68 53 125

9 Fixed Furniture & Carpentry Works 5 00 00 000

10 Elevators 1 08 00 000

11 Signage 48 00 000

12 Solid Waste Management System 25 00 000

13 Electrical works for Sports Fields Development 1 44 26 760

14 Swimming pool filtration system 96 25 000

Total Amount for Section B 23 88 63 325

Total Amount for Section A + B #REF!

Service Tax @ 4.12 % #REF!

Grand Total for the Works: #REF!

Amount in Words: Indian Rupees One Billion Six Hundred Fifty Million Fifty Seven
Thousand One Hundred and Sixty Five Only

Signature of Authorised Signatory Stamp of the Bidder

Please read this Abstract in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 1 of 55
Tender Documents
Aga Khan Academy, Hyderabad

SUMMARY FOR CIVIL WORKS

Sr. No. Description Total Amount (Indian Rupees)

1 Section 01 - Earth Work 83,323,264

2 Section 02 - Concrete Work 431,299,519

3 Section 03 - Form Work 71,035,613

4 Section 04 - Masonry Work 50,690,214

5 Section 07 - Plastering Work 24,713,357

6 Section 08 - Waterproofing Work 50,002,016

7 Section 09 - Flooring Work 237,142,265

8 Section 10 - Structural Steel Work 19,424,554

9 Section 11 - Painting Work 33,373,350

10 Section 15 - General Development Work #REF!

Total Amount: #REF!


Amount in Words:

Signature of Authorised Signatory Stamp of the Bidder

Please read this Abstract in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.
Page 2 of 55
02.12.09
Sr. N0. Item description Unit Quantity Rate Amount
SECTION 1 - EARTH WORK
Earth work in excavation by mechanical means / manual means in foundation trenches, drains, manholes and soak wells etc. including necessary shoring &
strutting, dewatering, getting out the excavated soil, sorting and stacking of useful material, dressing of the sides, ramming of bottom , backfilling into trenches and
1.01 disposal of surplus excavated earth at non objectionable place within the site as directed by engineer-in-charge All kinds of soil.

a) Depth upto 1.5m Cum 63,258 156 9,868,248


Rates in Words:
b) Depth 1.5m to 3m Cum 7,313 163 1,192,019
Rates in Words:
c) Depth 3m to 5m Cum 614 180 110,520
Rates in Words:
d) Depth 5m to 7m Cum 60 194 11,640
Rates in Words:
Earth work in excavation by mechanical means / manual means in foundation trenches, drains, manholes and soak wells etc. including necessary shoring &
strutting, dewatering, getting out the excavated soil, sorting and stacking of useful material, dressing of the sides, ramming of bottom , backfilling into trenches and
1.02 disposal of surplus excavated earth at non objectionable place within the site as directed by engineer-in-charge. For all civil, electrical and plumbing works.

1.02.2 Hard Rock (Requiring Blasting)


a) Depth upto 1.5m Cum 2,558 568 1,452,944
Rates in Words:
b) Depth 1.5m to 3m Cum 25 625 15,625
Rates in Words:
c) Depth 3m to 5m Cum 25 688 17,200
Rates in Words:
d) Depth 5m to 7m Cum 25 756 18,900
Rates in Words:
Earth work in excavation for mass areas, basements, water tanks, septic tanks, swimming pool etc. by mechanical means / manual means including necessary
shoring & strutting, dewatering, getting out the excavated soil, sorting and stacking of useful material, dressing of the sides, ramming of bottom and disposal of surplus
1.03.b excavated earth at non objectionable place within the site for all lifts as directed by engineer-in-charge

1.03.b.1 All Kinds of Soil


a) Depth upto 1.5m Cum 42,163 95 4,005,485
Rates in Words:
b) Depth 1.5m to 3m Cum 24,676 99 2,442,924
Rates in Words:
c) Depth 3m to 5m Cum 4,771 109 520,039
Rates in Words:
d) Depth 5m to 7m Cum 800 120 96,000
Rates in Words:
1.03.b.2 Hard Rock (Requiring Blasting)
a) Depth upto 1.5m Cum 27,029 332 8,973,628
Rates in Words:
b) Depth 1.5m to 3m Cum 15,951 348 5,550,948
Rates in Words:
c) Depth 3m to 5m Cum 2,681 383 1,026,823
Rates in Words:
d) Depth 5m to 7m Cum 100 421 42,100
Rates in Words:
Filling with available selected approved quality excavated earth (excluding rock and black cotton soil) brought from anywhere within the site in trenches, plinth, sides
1.14 of foundations etc. in layers not exceeding 15 cms in depth including watering, ramming, consolidating each deposited layer for all leads and lifts. Cum 76,277 95 7,246,315

Rates in Words:

1.15 Supplying and Filling in foundation and plinth with murrum or selected soil brought from outside in trenches, plinth, sides of foundation etc. in layers not Cum 55,837 307 17,141,959
exceeding 15 cm in depth, including watering, ramming, consolidating each deposited layer for all leads and lifts.
Rates in Words:
Filling in plinth with good quality river sand under floors including watering, ramming, consolidating and dressing complete.
1.16 Cum 3,987 1,180 4,704,660

Rates in Words:
Providing and laying rubble soling in plinth and for plinth protection, compacted thickness specified as following, using specified size of hard stones including
filling, covering and leveling the surface with a layer of murrum after filling the voids with smaller size black trap stones 20-40mm, 40-63mm, 63-90, 90-150mm size of
1.18.a stone/metals or stone chips, including watering, ramming well and consolidating each layer by static roller/ vibratory roller or as directed by Engineer-in charge

1.18.a.1 150mm compacted thickness using 100 to 150mm cut size stones Cum 2,432 1,110 2,699,520
Rates in Words:
1.18.a.2 230mm compacted thickness using 150 to 230mm cut size stones Cum 12,205 1,066 13,010,530
Rates in Words:
Disposing of the surplus excavated earth and/or debris etc. including loading at site, transporting by mechanical or manual means & disposal, unloading, spreading
1.19
and dressing and compacting etc. complete as directed.
1.19.1 Within the plot area as directed by Engineer in-charge. Cum 3,071 64 196,544
Rates in Words:
1.19.2 Outside the plot area at no-objection place Cum 500 195 97,500
Rates in Words:
Carrying out pre construction anti-termite treatment for all types of structure with / without basement with RCC foundation/RCC wall or with load bearing walled
foundation. The chemical used shall be like chloropyriphos , Biflex TC, lindane etc. as per latest IS code no 6313 (Part II) . Plinth area in plan at GF shall only be
1.20 measured and paid. A guarantee bond of 10 years shall be furnished. Rate shall be inclusive of material required for Anti Termite Treatment and labour for applying.. Sqm 30,347 39 1,183,533

Rates in Words:
Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and diposal of rubbish (unwanted material) anywhere
1.22 outside the site at non objectionable place. (Item shall be operated after prior approval from the client.) Site shall be selected by contractor.All kinds of Soil. Sqm 100,000 14 1,400,000

Rates in Words:

1.25 Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of the trunks and branches removing the roots and stacking of serviceable
material shall be at non objectionable place within the site and disposal of unserviceable material anywhere outside the plot area at non objectionable place for all
leads and lifts.Site shall be selected by contracor.
1.25.1 Beyond 30 cm girth upto and including 60 cm girth. No 175 517 90,475
Rates in Words:
1.25.2 Beyond 60 cm girth upto and including 120 cm girth. No 125 1,035 129,375
Rates in Words:
1.25.3 Beyond 120 cm girth upto and including 240 cm girth. No 5 7,781 38,905
Rates in Words:
1.25.4 Above 240 cm girth No 5 7,781 38,905
Rates in Words:
Sum Carried over to Summary page 83,323,264
SECTION 2 - CONCRETE WORK
Providing and laying in position Plain cement concrete (PCC) of specified grade including finishing, curing, formwork (if required) etc. complete as directed by the
2.01 engineer-in-charge - For All work upto Plinth level, Roads, Pavements, Plinth Protection, Kerbing etc.

2.01.3 1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) Cum 100 3,364 336,400
Rates in Words:
2.01.4 1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Cum 16,234 3,096 50,260,464
Rates in Words:
2.01.5 1:5:10 (1 Cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) Cum 50 2,858 142,900
Rates in Words:
Providing and laying BBCC (Brick Bat cement concrete) of specified grade including finishing, curing, form work (if required) etc. complete as directed by enginner in
2.06
charge. In foundations and Plinth.
2.06.1 1:3:6 (1 Cement : 3 Coarse Sand : 6 graded brickbats 40 mm maximum nominal size) Cum 1,509 3,100 4,677,900
Rates in Words:
REINFORCED CEMENT CONCRETE
Providing, hoisting (By Mechnical means), fixing exposed finish precast cement concrete work in M25 grade with minimum cement content 360 Kg per cum for
elements like lintels, beams, columns, slabs, window sills, shelves, moulding, cornices, trench covers etc including the cost of exposed centering, shuttering,
2.09.b rendering, erecting and keeping in position with cement mortar 1:3 (1 cement : 3 coarse sand)and necessary scaffolding at all floors, at any height and any level in any Cum 612 6,975 4,268,700
position etc. complete as directed by engineer-in-charge..

Rates in Words:
Sr. N0. Item description Unit Quantity Rate Amount
Providing and fixing precast fair finished exposed cement concrete Jali as per architectural design of M20 grade including centering and shuttering, cleaning, finishing
2.11.a and fixing in cement mortar 1:3 (1 cement: 3 fine sand) excluding plastering of the jambs, sills and soffits and cost of reinforcement as directed by engineer-in-charge

2.11.a.1 70 mm thick (reinforced as per drawing) Sqm 2,052 888 1,822,176


Rates in Words:
Providing and laying in position machine batched, machine mixed and machine vibrated design mix fair finish / smooth finish cement concrete of M20 grade with
minimum cement content 325 Kg per cum of concrete for reinforced cement concrete work for foundations, footings, RCC wall, slabs, beams, columns, staircase,
vertical and horizontal fins, doms, shells and vaults of any shape, all places, all heights including laying of concrete to site, finishing and curing etc. and including
Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, to improve workability without impairing strength and durability as per
direction of Engineer-in-charge. Rate shall be inclusive of providing grooves, drip moulds, ghisis, pockets, cutouts etc. and labour for insert sleeves if any wherever
2.12 required while casting. Rate also to include lift charges and scaffolding for all heights / depths from FFL / GL. Cum 11,718 4,213 49,367,934

Rates in Words:
2.12.1 Excluding the cost of centering, shuttering and reinforcement
Rates in Words:
Providing and laying in position machine batched, machine mixed and machine vibrated design mix fair finish / smooth finish cement concrete of M25 grade with
minimum cement content 360 Kg per cum of concrete for reinforced cement concrete work for foundations, footings, columns, slabs, beams, pillars, staircase, vertical
and horizontal fins, doms, shells and vaults of any shape including pumping laying of concrete to site, finishing and curing etc.and including Admixtures in
recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of
2.13 Engineer-in-charge. Rate shall be inclusive of providing grooves, drip moulds, ghisis, pockets, cutouts etc. and labour for insert sleeves if any wherever required while Cum 8,512 4,430 37,708,160
casting. Rate also to include lift charges and scaffolding for all heights / depths from FFL / GL

Rates in Words:
2.13.1 Excluding the cost of centering, shuttering and reinforcement
Rates in Words:
Providing and laying in position machine batched, machine mixed and machine vibrated design mix fair finish / smooth finish cement concrete of M30 grade with
minimum cement content 400 Kg per cum of concrete for reinforced cement concrete work for foundations, footings, columns, slabs, beams, pillars, staircase, vertical
and horizontal fins, doms, shells and vaults of any shape including pumping laying of concrete to site, finishing and curing etc.and including Admixtures in
recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of
2.14 Engineer-in-charge. Rate shall be inclusive of providing grooves, drip moulds, ghisis, pockets, cutouts etc. and labour for insert sleeves if any wherever required while Cum 100 4,679 467,900
casting. Rate also to include lift charges and scaffolding for all heights / depths from FFL / GL.

Rates in Words:
2.14.a1 Excluding the cost of centering, shuttering and reinforcement
Rates in Words:
Providing and laying in position machine batched, machine mixed and machine vibrated design mix fair finish / smooth finish cement concrete of M40 grade with
minimum cement content 450 Kg per cum of concrete for reinforced cement concrete work for foundations, footings, columns, slabs, beams, pillars, staircase, vertical
and horizontal fins, doms, shells and vaults of any shape including pumping laying of concrete to site, finishing and curing etc.and including Admixtures in
recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of
2.15b Engineer-in-charge. Rate shall be inclusive of providing grooves, drip moulds, ghisis, pockets, cutouts etc. and labour for insert sleeves if any wherever required while
casting. Rate also to include lift charges and scaffolding for all heights / depths from FFL / GL.

Rates in Words:
2.15b1 Excluding the cost of centering, shuttering and reinforcement Cum 0 4,990
Rates in Words:
Providing and laying Ready Mixed Concrete as per mix design of specified grade in fully automatic batching plant as per the design mix standards at RMC
2.16 manufacture’s site and transported to the place of work in transit mixer for any lead having continuous agitated mixture for reinforced cement concrete work.

The concrete is made using graded black trap stone aggregates of maximum 20mm nominal (down graded) size obtained from approved quarry including fine
aggregates conforming to latest IS 383 and cement all as per the design mix proportions conforming to IS 10262 with minimum cement content for durability including
supplying and providing concrete cover etc., which shall be followed as per latest IS 456 including pumping from transit mixer to all heights, placing, spreading,
vibrating, compaction, finishing to required levels, curing etc., complete all as per specifications but excluding cost of formwork and steel reinforcement. Rate to
include charges for providing and mixing additives or admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve
workability without impairing strength and durability, and labour for keeping embedment, insert sleeves) if any wherever required while casting. Rate also to include
lift charges and scaffolding for all heights / depths from FFL / GL.Contractor shall get prior approval of the mix design before placing the order.

Note:
Ready Mixed Concrete should be from reputed manufacturers like ACC, L&T, Ready Mix, Birla RMC etc., and contractors have to obtain prior approval of EIC with
(i)
respect to supplier of RMC.

(ii)
Rate to include the transportation with all leads from RMC plant to the place of work and pumping of concrete to any height and the rate shall be for all leads

(iii) Cement concrete delivered at site should be workable and should satisfy all the required standard tests like cube test and slump test etc or item description as
specified in code of practice. Samples taken at site only will be deciding factor.
It is the responsibility of contractor ensures proper co-ordination for the timely supply of concrete and approved quality product
(iv)

(v) Contractor has to make arrangement for proper approach road (for which nothing extra shall be paid for) to enable the vehicle carrying concrete to move freely
without any extra cost to the department before ordering the concrete. However existing approach road may be made use of for this purpose
(vi) Contractor has to ensure proper strong shuttering / centering to receive the concrete at all heights.
The design mix of RMC for the manufacturer / supplier of RMC has to be obtained well in time and approval of Engineer in Charge to be obtained prior to use. The
design mix should be based on latest IS 456. This approval has to be obtained whenever the design mix is changed. The RMC should be supplied confirming to the
(vii) approved design mix which shall be continously checked during the progress of work. All the quality checks as per IS stipulations should be scruplously followed
during the concreting. The work shall be carried out at all heights.

2.16.2 M20 Grade with (minimum cement 260 Kg + Flyash in reuiqred proportion) per cum Cum 9,793 3,977 38,946,761
Rates in Words:
2.16.3 M25 Grade with (minimum cement 288 Kg + Flyash in required proportion) per cum Cum 7,780 4,175 32,481,500
Rates in Words:
2.16.4 M30 Grade with (minimum cement 320 Kg + Flyash in required proportion) per cum Cum 100 4,372 437,200
Rates in Words:

2.17.a Supplying, fabricating and placing in position TMT reinforcement bars FE 415 confirming to IS-1786 reinforcement for RCC structure / items as per design
including transporting steel to the work site, handling wastage, decoiling, cutting, bending, cranking, fabricating to required shape, placing in position, binding with 18
guage (1.22 mm) MS wires, welding if necessary by using approved welding rods etc. for all levels etc. complete as directed by the engineer-in-charge. The quoted
rate should be inclusive the cost of binding wire and the same will not be measured and paid seprately. (rolling margin's and wastage shall not be paid.) Measurement
will be made on the length basis and converted into weight by using standard co-efficient) . The reinforcement shall be
2.17.a3 TMT bars- Fe-415, yield stress not less than 415 N/mm2 MT 4,305 48,069 206,937,045
Rates in Words:
Charges for making holes in walls, slabs, beams upto 350 mm depth or any other RCC member by core cutting machine of HILTI or equivalent including disposing
the debris. Measurement will be taken for the depth of holes in running meter for specified diameter. For disposal of the debris specification of relevant items shall be
2.19 followed. For executing the item prior approval of the structural consultant is required.

2.19.1 In RCC elements


a Holes of 52 mm clear diameter Rmt 50 1,919 95,950
Rates in Words:
b Holes of 67mm clear diameter Rmt 1 2,029 2,029
Rates in Words:
c Holes of 77mm clear diameter Rmt 1 2,160 2,160
Rates in Words:
d Holes of 102mm clear diameter Rmt 75 2,643 198,225
Rates in Words:
e Holes of 152 mm clear diameter Rmt 25 2,885 72,125
Rates in Words:
f Holes of 202 mm clear diameter Rmt 10 3,126 31,260
Rates in Words:
2.19.2 In Brick Masonry
a Holes of 52 mm clear diameter Rmt 1 1,436 1,436
Rates in Words:
b Holes of 67mm clear diameter Rmt 1 1,556 1,556
Rates in Words:
Sr. N0. Item description Unit Quantity Rate Amount
c Holes of 77mm clear diameter Rmt 1 1,677 1,677
Rates in Words:
d Holes of 102mm clear diameter Rmt 1 1,919 1,919
Rates in Words:
e Holes of 152 mm clear diameter Rmt 1 2,643 2,643
Rates in Words:
f Holes of 202 mm clear diameter Rmt 1 2,885 2,885
Rates in Words:
2.19.3 In Stone Masonry
a Holes of 52 mm clear diameter Rmt 1 2,544 2,544
Rates in Words:
b Holes of 67mm clear diameter Rmt 1 2,655 2,655
Rates in Words:
c Holes of 77mm clear diameter Rmt 1 2,786 2,786
Rates in Words:
d Holes of 102mm clear diameter Rmt 1 3,269 3,269
Rates in Words:
e Holes of 152 mm clear diameter Rmt 1 3,511 3,511
Rates in Words:
f Holes of 202 mm clear diameter Rmt 0 3,752
Rates in Words:
2.20 Providing in position UPVC sleeves of 6Kg/cm2 and length upto 500 mm for following diameters of
2.20.1 200mm dia No 40 547 21,880
Rates in Words:
2.20.2 160mm dia No 70 335 23,450
Rates in Words:
2.20.3 110mm dia No 80 159 12,720
Rates in Words:
2.20.4 75mm dia No 140 78 10,920
Rates in Words:
2.21 Providing additional cement in design mix of RCC to achieve desired exposed finish surface. Kg 5,000 5 25,000
Rates in Words:
Providing and fixing in expansion joints, Capcell HD 100 Supreme or equivalent (Polyurethane foam filler) of the best quality, including in all shapes and all levels
2.22
etc. complete as directed by engineer-in-charge..
a) 25 mm thk Sqm 1,455 879 1,278,945
Rates in Words:
Providing and filling the expansion joints, with polysulphide sealant with application of primer including scraping / removing the expansion filler materials from
joints, cleaning, repaing of the edges with epoxy mortar of approved color and make, placing of backup material (polyethylene baker rod of Supreme), fixing of abro
2.23 tapes on the edges to prevent the adjoining surface, etc. complete as directed by engineer-in-charge. The contractor should furnish a gurantee of 10 years as directed.

a) size of expansion joint 25mm x 12mm Rmt 995 482 479,590


Rates in Words:
Providing and fixing in expansion joints, copper strip water stop of 1.25 mm thick & 125 mm wide with 'U' of 25 mm depth in middle with 3 mm dia copper rod 25
2.24 cm long, soldered on strip at an interval of 30 cm as specified in drawing, as per sample approved and as directed by Engineer-In-Charge Rmt 884 1,316 1,163,344

Rates in Words:
Sum Carried over to Summary page 431,299,519
SECTION 3 - FORM WORK
Form Work (Centering and shuttering) including strutting, propping, bracing etc. complete to give fair / smooth finish using best quality ordinary timber planking,
shuttering plywood (plain or laminated) or steel plates with MS adjustable steel props, H frames with bracing, adjustable spans, etc. including removal of forms for
foundations, footings, bases of columns, walls, slabs beams, sills, lintels, coping, staircases, arches, chajjas etc. in all shapes at all levels etc. complete as directed by
3.01 engineer-in-charge. The Height of propping and centering from supporting floor to ceiling should not exceed 4.5 meter. Sqm 188,891 354 66,867,414

Rates in Words:
Extra over item no. 3.01 (Form Work) for providing and erecting false staging with MS props or MS H frames for each additional height of propping and centering
where the height of propping and centering exceeds 4.5 m between supporting floor to ceiling, including temporary masonry work, stone pillars for supporting as
3.02.a required for steel props, H Frames etc. including cost of deshuttering and centering at all levels. (height more than 4.5 m. and upto 9.0 m) No staging shall be Sqm 3,957 77 304,689
measured for vertical walls & beam sides and only plan area is to be measured.

Rates in Words:
Extra over item no. 3.01 (Form Work) for providing and erecting false staging with MS props or MS H frames for each additional height of propping and centering
where the height of propping and centering exceeds 9.0 m. between supporting floor to ceiling, including temporary masonry work, stone pillars for supporting as
required for steel props, H Frames etc. including cost of deshuttering and centering at all levels.(height more than 9.0 m. and upto 18.0 m between supporting
3.02.b floor to ceiling). No staging shall be measured for vertical walls, columns & beam sides and only plan area is to be measured. Sqm 364 195 70,980

Rates in Words:
Extra over item no. 3.01 (formwork) for providing formwork for exposed concrete surfaces (vertical or horizontal surface) in desired pattern and size, using
laminated shuttering plywood, for slabs, soffits, walls, columns, pillars, beams, lintels, beam hunching, vertical fins etc. including neat cleaning the exposed
3.03.a concrete surface, as directed by the engineer-in-charge. (Same kind of shuttering material should be only used for standard and residual sizes.) Sqm 23,945 119 2,849,455

Rates in Words:
Extra over item no. 3.01 (formwork) for providing formwork for exposed concrete surfaces ( vertical or horizontal surface) in desired pattern and size, using best
quality steel shuttering plates, steel sheeting, for slabs, soffits, walls, columns, pillars, beams, lintels, beam hunching, vertical fins etc. including neat cleaning the
3.03.b exposed concrete surface, as directed by the engineer-in-charge. (Same kind of shuttering material should be only used for standard and residual sizes.) Sqm 7,925 119 943,075

Rates in Words:
Sum Carried over to Summary page 71,035,613
SECTION 4 - MASONRY WORK
Providing and laying brick work using common burnt clay conventional building bricks conforming to IS 1077-1992 having compressive strength not less than 50
4.01 Kg/cm2 in any shape and all depth including curing, scaffolding etc. complete as directed by engineer-in-charge.

4.01.1 In foundations and Plinth


(i) CM 1:4 (1 Cement : 4 coarse Sand) Cum 1,079 2,933 3,164,707
Rates in Words:
4.01.2 Super structure plinth for all levels
(iii) CM 1:6 (1 Cement : 6 coarse Sand) Cum 12,143 2,941 35,712,563
Rates in Words:
Providing and laying half brick masonry with common burnt clay building bricks having compressive strength not less than 50 Kg/cm2 at all heights, levels,
4.04.a locations and shapes etc. including curing, scaffolding etc. complete as directed by the engineer-in-charge

4.04.a.2 Without Reinforcement


(A) 115 mm thick
(ii) CM 1:4 (1 Cement : 4 coarse Sand) Sqm 5,346 384 2,052,864
Rates in Words:
Providing and fixing 190mm x 190 mm x 80 mm glass bricks of approved make and design with white CM 1:2 ( 1 white cement : 2 sand). Two numbers of 5 mm
thick GI wires to be passed through PVC spacers in each joint horizontal as well as vertical by drilling holes in surrounding surface (brick or RCC) and filling the same
with Hilti or equivalent chemical (rebarring). The PVC concealed spacer (with provision for passing the 2 no. GI wires in horizontal and vertical direction) shall be
provided to maintain grooves/spaces for GI wire and white cement mortar at the junction of two glass bricks. The sample of the glass brick shall be got approved by
Architect. The glass bricks shall be fixed with placing GI wires vertically as well as horizontally after passing through the spacer and having minimum lap length of +
200 mm as per the site conditions at all the places, heights and shapes, etc. complete, as per the details and drawing to the satisfaction of Engineer-in-charge. Joints
4.09 along the periphery of glass bricks to be filled with approved make and color weather silicone sealant of DOW corning or equivalent. Sqm 25 7,507 187,675

Rates in Words:
4.10 Extra for providing exposed finish to brickwork at all heights, shapes in any position. The bricks used shall be
4.10.1 Wire Cut bricks Cum 25 2,260 56,500
Rates in Words:
4.10.2 Best quality hand moulded bricks Cum 25 1,624 40,600
Rates in Words:
Providing and laying uncoursed rubble masonry, with hard stone, locally available granite stone approved by architect, in foundations and plinth, in CM 1:4 (1
4.11 cement : 4 coarse sand) including leveling, etc. complete, as directed by engineer in charge. Cum 806 2,372 1,911,832

Rates in Words:
Sr. N0. Item description Unit Quantity Rate Amount
Providing and laying uncoursed rubble masonry with hard stone, locally available granite stone approved by architect in superstructure above plinth and for all
4.13 floors in CM 1:6 including curing, leveling etc. complete as directed by engineer in charge. Cum 2,837 2,406 6,825,822

Rates in Words:
Providing and laying coursed rubble masonry with hard stone, locally available granite stone approved by architect in superstructure above plinth and for all floors
4.14 in CM 1:6 including curing, leveling etc. complete as directed by engineer in charge. Cum 277 2,663 737,651

Rates in Words:
Sum Carried over to Summary page 50,690,214
SECTION 7 - PLASTERING WORK
Providing and laying average 10 mm thick single coat mala finish (finished smooth with steel trowel) plaster in CM 1:3 , on ceilings and stair soffits at all floors,
all shapes and all heights with necessary scaffolding, curing, making grooves, forming pattas, hacking properly to RCC surface (144 nos. of hacks per sqft) etc.
7.01.b complete as directed by Engineer-in-charge. The plaster mortar shall be machine mixed. Sqm 44,424 160 7,107,840

Rates in Words:
Providing and laying average 15 mm thick single coat mala finish plaster in CM 1:4 (1 cement : 4 Coarse sand) with polypropylene fibers in recommended
proportions on sides of brickwork/ blocks at all floors, all shapes and all heights with necessary scaffolding, curing, making grooves, forming pattas, hacking properly
7.02.b RCC surface etc. complete as directed by the Architect and Engineer-in-charge. The plaster mortar shall be machine mixed. Sqm 73,779 160 11,804,640

Rates in Words:
Providing & laying average 18 mm thick mala finish cement plaster in two coats at all heights, all shapes and all levels with 12 mm thick under coat in CM 1:4 (1
cement : 4 coarse sand) rough wired finish and 6 mm thick finishing coat in CM 1:3 (1 cement : 3 fine sand) mala finish (finished with steel trowel) including
7.03.a scaffolding, curing, making grooves, forming pattas and drip mould, hacking RCC surface etc. complete, as directed by Engineer-In-charge. The plaster mortar shall Sqm 20,941 211 4,418,551
be machine mixed.

Rates in Words:
Providing and laying average 18-20 mm. thick Sand face cement plaster on walls upto any height above ground level and for all shapes consisting of average 12-
15 mm. thick backing coat of CM 1:4 (1 cement: 4 coarse sand) with polypropelene fibersand average 6 mm. thick uniform grained textured finish coat using wooden
7.04.a Gutka, in CM 1:3 (1 cement: 3 sand), including scaffolding, forming grooves, drip moulds, pattas, hacking RCC surface, curing etc. complete as directed by engineer- Sqm 1,226 234 286,884
in-charge. The plaster mortar shall be machine mixed.

Rates in Words:
Providing and fixing hexagonal chicken mesh of size 20 mm. x 20 mm. of 22 gauge at junction of concrete and brick work or between different materials, etc. as
7.10 Sqm 12,947 76 983,972
directed by engineer in charge.
Rates in Words:
7.11.a Flush pointing on the following work with Cement Mortar 1:2 (1 Cement : 2 Fine Sand)
7.11.a.1 Brick work Sqm 100 70 7,000
Rates in Words:
7.11.a.3 Coursed Rubble masonry Work Sqm 100 70 7,000
Rates in Words:
7.11.a.4 Uncoursed Rubble masonry Work Sqm 100 70 7,000
Rates in Words:
7.11.c Recessed pointing on the following work with Cement Mortar 1:2 (1 Cement : 2 Fine Sand)
7.11.c.1 Brick work Sqm 100 83 8,300
Rates in Words:
7.11.c.3 Coursed Rubble masonry Work Sqm 990 83 82,170
Rates in Words:
Sum Carried over to Summary page 24,713,357
SECTION 8 - WATERPROOFING WORK
Providing and laying integral cement based brickbat coba water proofing treatment average 115mm thick and minimum thickness at khurra as 65 mm including
8.01.a preparation of surface as required for treatment on roofs, balconies, terraces etc. at all floors consisting of following operations and furnishing a guarantee bond of 10 Sqm 24,524 545 13,365,580
years.

Rates in Words:
Cleaning and applying a cement slurry with mixed with water proofing compound as manufacture's specification as directed by engineer-in-charge over the slab
i) including adjoining walls upto 300 mmheight including cleaning the surface before the treatment

Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water
proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand )
ii) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto
300 mm height including rounding of junctions of walls and slabs.

After three days of proper curing applying a second coat of cement slurry admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-
iii)
in-charge
Finishing the surface to make wired finish with average 12 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing
iv)
compound conforming to IS : 2645 and approved by Engineer-in-charge
The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and
v) as directed and specified by the Engineer-in-Charge. (Only plan area shall be measured, vata shall not be measured separately and paid for.)

Providing and laying integral cement based brickbat coba water proofing treatment average 75mm thick including preparation of surface as required for
8.02.a treatment on sunk slabs of toilets, depressed portions etc. at all floors consisting of following operations and furnishing a guarantee bond of 10 years. Sqm 4,518 545 2,462,310

Rates in Words:
Providing and laying crystalline water proofing treatment of ZYPEX or equivalent to vertical and horizontal surfaces of depressed portions of toilets, pantry and the
like as per manufacture’s specification or as directed by the engineer-in-charge and furnishing a guarantee bond of 10 years. Only plan area shall be measured, vata
8.02.c shall not be measured separately and paid for.) Sqm 497 426 211,722

Rates in Words:
Providing 18 to 20 mm. thick Water proof cement plaster in double coat on sides of masonry / RCC wall at all heights, first coat of 12 to 15 mm thk under coat in
cement mortar 1:3 (1 cement : 3 sand) and second coat of 5 to 6 mm thk with cement mortar 1:3 (1 cement : 3 sand) including providing and mixing water proofing
compound such as Hydroshield powder & liquid of ConTech Chemicals, Fosroc, CICO or equivalent in recommended proportions in both coats as approved by the
Architect and Engineer-in-charge and finishing the surface smooth finish with neat cement slurry at 2.75 Kg per sqm etc complete including furnishing a guarantee
8.05.b bond for 10 years, hacking to RCC surface. Cement slurry admixed with Hydroshield powder & liquid of ConTech Chemicals, Fosroc, CICO or equivalent in Sqm 5,095 292 1,487,740
recommended proportions is to be applied before each coat and final finishing coat

Rates in Words:
Providing and laying average 60 mm thick water proof cement concrete flooring in 1:2:2 (1 Cement : 2 Sand : 2 Graded Aggregate 10mm nominal size) to RCC
swimming pool floor, water tanks at all heights in line, level and gradient including mixing water proofing compound such as Hydroshield powder & liquid of ConTech
Chemicals, Fosroc, CICO or equivalent in recommended proportions as approved by the Architect and Engineer-in-charge and leaving the surface rough wired finish
8.06 to receive any type of flooring / smooth finish etc complete including furnishing a guarantee bond for 10 years. Rate shall be inclusive of curing, scaffolding etc. as Sqm 4,651 284 1,320,884
directed

Rates in Words:
Providing and placing in position suitable size (width, thickness based on water head and pressure) PVC water stops conforming to IS : 12200 as approved by
consultant for construction / expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete as
8.12 directed by engineer in charge. Rmt 118 486 57,348

Rates in Words:
Providing and laying over deck insulation over terrace water proofing of 115 mm thick ex-foliated vermiculite of Porosil or equivalent for roof insulation in the
ratio of 1 :6 (1 cement : 6 Ex foliated vermiculite (by volume)). Density of Ex foliated vermiculite shall be 212 kg/cum. The cement shall be mixed with the ex foliated
vermiculate in dry stage & then minimum qty of water shall be added. After screeding the ready mixed material in specified thickness, curing shall be carried out at
least for for 7 days by sprinkling of required quantity of water so that surface remains damp and not to be done by ponding or flooding. The work includes cleaning of
8.13 the surface with wire brush thoroughly necessary scaffolding finishing the top surface as best workmanship like manner as per the manufacturers specifications and Sqm 24,524 1,268 31,096,432
as directed by Engineer In charge.

Rates in Words:
Sum Carried over to Summary page 50,002,016
SECTION 9 - FLOORING WORK
Providing and laying ceramic tiles of required surface finish (Matt, Satin, Glossy, Non skid, Rustic) in floor with residue and skirting of approved make and shade as
per design laid over 20 mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand) bedding on 40 mm wired finish screed 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 12.5 mm nominal size ), laid to proper slope and level. Finishing should be done with pointing the joints with white cement and matching pigment,
including curing, cleaning with mild oxalic acid, protecting the flooring until handing over to the client etc. complete as directed by Engineer-in-charge. The rate should
9.02.a include the covering & protecting of flooring with plastic + POP, or as required, removing the same at the time of handing over after completion of the item until Sqm 1,050 844 886,200
handing over to client.

Rates in Words:
Sr. N0. Item description Unit Quantity Rate Amount
Providing and laying in position ceramic wall tiles of required surface finish (Matt, Satin, Glossy, Non skid, Rustic) for dado, risers of steps etc. of approved make
and shade as per design and drawing. Tile is to be fixed over 12 to 15 mm thick wired finish plaster in cement mortar 1:4 ( 1 cement : 4 coarse sand) with
polypropylene fibers. Tile shall be fixed with 1:1 cement sand mortar of average 6 mm thickness behind the tiles including pointing in white cement mixed with pigment
of matching shade etc. complete as approved by architect and directed by engineer-in-charge. Rate is inclusive of back coat of 12 to 15 mm thick plaster. The rate
should include the covering & protecting of flooring with plastic + POP, or as required, removing the same at the time of handing over after completion of the item until
9.02.c handing over to client. In case of hollow sound upon tapping the tile after laying / fixing, the tile would have to be removed and replaced at contractors cost. Sqm 50 755 37,750

Rates in Words:
Providing and fixing ceramic tiles in dado of required surface finish (Matt, Satin, Glossy, Non skid, Rustic) with cement based polymer adhesive like BAL or
equivalent with minimum 3 mm thickness or as manufacture’s specification. The material, workmanship, coverage area shall be carried out as per the supplier’s
specifications and approved by architect and engineer-in-charge. In dado adhesive is to be applied over smooth finish mala plaster (1:4) instead of wired plaster. Rate
is inclusive of mala finish plaster on the masonry wall. The rate should include the covering & protecting of flooring with plastic + POP, or as required, removing the
9.02.d same at the time of handing over after completion of the item until handing over to client. Sqm 50 984 49,200

Rates in Words:
Providing and laying vitrified tiles of approved make and shade as per design in floor with residue and skirting of desired colors and size of first quality over a
minimum 20 mm. thick cement mortar 1:3 bedding on 40 mm wired finish screed and laid to proper slope and level. Finishing to be done with flush pointing in white
cement and matching pigment including curing and cleaning with mild oxalic acid etc. complete as directed by Architects and Engineer-in-charge. Rate shall be
inclusive of protection of flooring until the handling of the project by covering the joints with abrotaps, platic sheet and plaster of paris & removing the same at the time
9.03.a of handing over as directed by engineer in charge. Sqm 50 1,644 82,200

Rates in Words:
Providing and laying vitrified tiles of approved make and color as per design in floor with residue and skirting of desired colors and size of first quality, over a
minimum 20 mm. thick cement mortar 1:3 bedding on 40 mm wired finish screed and laid to proper slope and level. Groove of (3mm x 5mm) is prepared with PVC
spacer of approved make and filling in groove is to be done with cementitious grout of matching shade including curing and cleaning with mild oxalic acid etc.
complete as directed by Architects and Engineer-in-charge. Rate shall be inclusive of filling in grooves with cementitious grout and protection of flooring until the
9.03.b handling of the project by covering the joints with abrotaps, plastic sheet and plaster of paris & removing the same at the time of handing over as directed by engineer Sqm 3,233 1,660 5,366,780
in charge.

Rates in Words:
Providing and laying in position vitrified wall tiles of required surface finish (Matt, Satin, Glossy, Non skid, Rustic) for dado, risers of steps etc. of approved make
and shade as per design and drawing. Tile is to be fixed over 12 to 15 mm thick wired finish plaster in cement mortar 1:4 (1 cement : 4 coarse sand) with
polypropylene fibers in recommended proportions with keeping a groove of (3mm width X 5 mm depth). Tile shall be fixed with 1:1 cement sand mortar of average 6
mm thickness behind the tiles including filling the grooves with cementitious grout of matching shade etc. complete as approved by architect and directed by
engineer-in-charge. Rate shall be inclusive of 12 to 15 mm thick wired finish plaster with polypropylene fibers in cement mortar 1:4 and filling in grooves with
cementitious grout. The rate should include the covering & protecting of flooring with plastic + POP, or as required, after completion of the item until handing over to
9.03.d client & removing the same at the time of handing over to client. In case of hollow sound upon tapping the tile after laying / fixing, the tile would have to be removed Sqm 9,356 1,571 14,698,276
and replaced at contractors cost.

Rates in Words:
Providing and fixing vitrified tiles in dado with cement based polymer adhesive like BAL or equivalent in with minimum 3 mm thickness or as manufacture’s
specification. The material, workmanship, coverage area shall be carried out as per the supplier’s specifications and approved by architect and engineer-in-charge. In
dado adhesive is to be applied over smooth finish mala plaster instead of wired plaster. Rate is inclusive of smooth finish mala plaster. The rate should include the
9.03.e covering & protecting of flooring with plastic + POP, or as required, after completion of the item until handing over to client and removing the same at the time of Sqm 25 1,784 44,600
handing over to client.

Rates in Words:
Cement concrete flooring (IPS) 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate) laid in one layer finished with trowel finish using 1:1 cement sand mortar for
filling the minor holes etc. or alternate panels using 5 mm thk glass strips finished with a trowel including curing etc. complete as per design or as directed by
9.04.a engineer-in-charge.

9.04.a.2 50 mm thick with 6 to 10 mm nominal size stone aggregate Sqm 200 247 49,400
Rates in Words:
Supplying and sprinkling nonmetallic floor hardener of Ironite or equivalent @ 4 Kg per sqm or as per supplier's specification over green concrete surface / IPS.
9.04.b Rate includes finishing surface with power floater as per design or as directed by engineer-in-charge. Kg 3,120 36 112,320

Rates in Words:
Extra for providing and mixing Fibermesh 150 e3 ( Formerly Stealth e3 ) multi dimensional graded multifilament 100% virgin polypropylene fibers
manufactured by M/s. PROPEX CONCRETE SYSTEMS, U.S.A. and represented by “M/s. NINA CONCRETE SYSTEMS PVT. LTD.@ 0.9 Kg per cum or as per
9.04.c manufacture’s specification of approved make while doing the cement concrete in cement concrete pavement / IPS as per supplier's specification and approved by Kg 1,000 492 492,000
architect and engineer-in-charge.

Rates in Words:
Providing & laying broken white china mosaic flooring for plain and curved surfaces, comprising of 20 to 25 mm. size broken pieces of ceramic/glazed tiles laid
over cement mortar 1:6 bedding including applying cement slurry at the rate of 2.75 kg per sq.m. on plain or sloped surfaces. and filling joints with white cement. The
flooring shall be tampered to bring the mortar up to the surface, including rounding of the junctions and extending them upto 15 cm. along the parapet wall. The rate
shall include bands, if different colour is used, any pattern or design as per drawing and direction, curing, cleaning with water and oxalic acid, etc. complete. (Wall to
wall measurement will be considered only including vata upto 150mm height). The rate should include the covering & protecting of flooring with plastic + POP or as
9.09.a required after completion of the item until handing over to client and removing the same at the time of handing over. Sqm 27,746 455 12,624,430

Rates in Words:
Providing and laying in position white china mosaic on dado comprising of 20 to 25 mm size broken pieces of ceramic / glazed tiles laid over 12 to 15 mm thick
wired finish plaster in cement mortar 1:4 ( 1 cement : 4 coarse sand) with polypropelene fibers including applying a cement slurry at 2.75 Kg per sqm on plastered
surface. China mosaic shall be fixed with 1:2 cement sand mortar of average 6 mm thickness including filling the joints with white cement. The dado shall be tampered
to bring the mortar up to the surface. The rate shall be inclusive of bands, if different color is used, any pattern or design as per drawing and direction, curing,
scaffolding, cleaning with water etc. complete as directed by the engineer in charge. Rate is inclusive of 12 to 15 mm thk wired finish plaster in cement mortar 1:4.
9.09.b The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing Sqm 4,410 555 2,447,550
the same at the time of handing over.

Rates in Words:
Providing and laying average 25mm (20 to 30 mm) thick hand dressed / machine cut green polished kotah stone of approved quality, selected and sorted for
uniform colour, in floor, otta and skirting etc. of required sizes upto 600 mm as per design in normal pattern (square or rectangular) and residue as per drawing,
including 1:6 (1 cement : 6 sand) cement mortar bedding of average 35 to 50mm thickness, jointed with grey cement and colour pigment as specified. Polishing to be
done with 2 coats of 60, 120 grades of emery, balckchapadi and gutka for special polish, after it polishing to be done with 220, 320, 400, 600 grades of emery till
semimirror finish is achieved. Curing, daily moping with water & kerosene as directed for at least 15 days after final polishing etc. complete with marble stone to form
bands (marble flooring and bands shall be paid under relevant item) upto the satisfaction of the Architect or Engineer-in-charge.(NO WAXING WILL BE
9.10.a PERMITTED.)The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client Sqm 37,715 1,152 43,447,680
and removing the same at the time of handing over.

Providing and laying average 25mm (20 to 30 mm) thick hand dressed / machine cut green polished kotah stone of approved quality, selected and sorted for uniform
color, in floor, otta and skirting etc. of required sizes upto 600 mm as per design in diagonal pattern and residue as per drawing, including 1:6 (1 cement : 6 sand)
cement mortar bedding of average 35 to 50mm thickness, jointed with grey cement and colour pigment as specified. Polishing to be done with 2 coats of 60, 120
grades of emery, balckchapadi and gutka for special polish, after it polishing to be done with 220, 320, 400, 600 grades of emery till semimirror finish is achieved.
Curing, daily moping with water & kerosene as directed for at least 15 days after final polishing or upto the satisfaction of the Architect or Engineer-in-charge etc.
complete. (NO WAXING WILL BE PERMITTED). The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of
9.10.b the item until handing over to client and removing the same at the time of handing over. Sqm 100 1,287 128,700

Rates in Words:
Sr. N0. Item description Unit Quantity Rate Amount
Providing and laying average 25mm (20 to 30 mm) thick hand dressed / machine cut green polished kotah stone of approved quality selected and sorted for uniform
colour, in floor, otta and skirting etc. of required sizes above 600 mm and upto 1000 mm as per design in normal pattern (square or rectangular) and residue as per
drawing, including 1:6 (1 cement : 6 sand) cement mortar bedding of average 35 to 50mm thickness, jointed with grey cement and color pigment as specified.
Polishing to be done with 2 coats of 60, 120 grades of emery, balckchapadi and gutka for special polish, after it polishing to be done with 220, 320, 400, 600 grades of
emery till semimirror finish is achieved. Curing, daily moping with water & kerosene as directed for at least 15 days after final polishing or upto the satisfaction of the
Architect or Engineer-in-charge etc. complete. (NO WAXING WILL BE PERMITTED). The rate should include the covering & protecting of flooring with plastic + POP
9.10.c or as required after completion of the item until handing over to client and removing the same at the time of handing over. Sqm 50 1,287 64,350

Providing and laying in position average 10 mm thick green kota stone of approved quality, selected and sorted for uniform color in skirting of required size as
per design and drawing. Kota stone is to be fixed over 8 mm thk cement mortar (1:1) jointed with grey cement and color pigment. Polishing to be done with 2 coats of
60, 120 grades of emery, balckchapadi and gutka for special polish, after it polishing to be done with 220, 320, 400, 600 grades of emery till semimirror finish is
achieved. Curing, daily moping with water & kerosene as directed for at least 15 days after final polishing or upto the satisfaction of the Architect or Engineer-in-charge
9.10.e etc. complete, (NO WAXING WILL BE PERMITTED). The rate should include the covering & protecting of flooring with plastic + POP or as required after completion Sqm 1,055 1,093 1,153,115
of the item until handing over to client and removing the same at the time of handing over.

Rates in Words:
Providing & laying average 25 mm thick stone of following type of approved quality, selected and sorted for uniform color, in floor, otta, sill, skirting, tread, riser etc., in
required sizes upto 60 cm. as per design and drawings (with grooves). Kota stone to be laid over cement mortar 1:6 bedding of average 35 to 40 mm thickness with
joints, pointing and making grooves as specified, including curing and cleaning upto the satisfaction of the Architect & Engineer-in-charges etc. complete. (NO
WAXING WILL BE PERMITTED) The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until
9.12.a handing over to client and removing the same at the time of handing over.

9.12.a.1 Rough Kota Stone Sqm 14,574 950 13,845,300


Rates in Words:
9.12.a.2 Rough Tandoor Stone Sqm 13,000 540 7,020,000
Rates in Words:
9.12.a.3 Rough Black Kadappa Stone Sqm 13,000 654 8,502,000
Rates in Words:
Providing & fixing average 25 mm thick single side prepolished (upto semimirror finish) green kotah of uniform size and color for platforms, staircases, sinks,
shelves, morry etc. from 1.0 m. to 1.5 m long, including necessary machine-cut edges (uniform thickness) rounded edges, necessary cement mortar bedding in CM
1:3 of average 20 mm thickness. Cement joints and pointing as specified with polishing, curing, daily mopping with water and kerosene as directed for atleast 15 days
or upto the satisfaction of the Architect & Engineer-in-charge etc. complete. The rate should include the covering & protecting of flooring with plastic + POP or as
9.13.c required after completion of the item until handing over to client and removing the same at the time of handing over. Sqm 2,491 1,204 2,999,164

Rates in Words:
Providing & fixing average 25 mm thick both side prepolished (upto semimirror finish) green kota of uniform size and color for shelves and vertical partitions etc.
from 1.0 to 1.5m long, including necessary machine-cut edges (uniform thickness) rounded edges, necessary cement mortar bedding in CM 1:3 of average 20 mm
9.13.d thickness. Cement joints and pointing as specified with polishing, curing, daily mopping with water and kerosene as directed for atleast 15 days or upto the satisfaction Sqm 458 1,245 570,210
of the Architect & Engineer-in-charge.

Rates in Words:
Providing & fixing green pre polished kota (upto semimirror finish) of average 50 mm. thick of uniform size and colour for sills, floor etc. in required sizes from 1.0
m. to 1.5 m. long, including necessary machine-cut edges (uniform thickness), rounded edges, necessary cement mortar bedding in CM 1:3 of required thickness,
average 20 mm. Cement joints and pointing as specified with polishing , curing, daily mopping with water and kerosene as directed for atleast 15 days or upto the
satisfaction of the Architect & Engineer-in-charge. The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of
9.14 the item until handing over to client and removing the same at the time of handing over. Sqm 50 1,261 63,050

Rates in Words:
Providing roughened strip 2.5 cm. wide to form antiskid surface on any flooring as per design, including forming straight deep curved gishi (groove), 6 mm. Wide
& 4 mm deep on two sides of the roughened area, chiseling, polishing the edges, sides and bottom of gishis etc. complete as per sample approved and as directed by
9.15 engineer in charge. Rmt 2,726 162 441,612

Rates in Words:
Extra for providing special mirror finish polish on kotah flooring over semi mirror polish with different grades of emery like 800, 1200, 5x and buffing with tin oxide.
9.16 Sqm 1,000 115 115,000
All work to be carried out with polishing machine.
Rates in Words:
Providing and laying average 18 mm thick marble stone flooring of approved quality (sample of marble stone shall be approved by architect) as per design in
required sizes and shapes including bands in polished kotah stone flooring over 35 to 40 mm (average) thick bedding of cement mortar 1:3 (1 cement: 3 coarse sand)
laid and jointed with white cement and matching pigment including rubbing, semi mirror polishing with different grades of Emery, curing etc. complete.Polishing to be
done with 2 coats of 60, 120 grades of emery, balckchapadi and gutka for special polish, after it polishing to be done with 220, 320, 400, 600 grades of emery till
9.17 semimirror finish is achieved. (Only finished marble work will be measured.) The rate should include the covering & protecting of flooring with plastic + POP or as Sqm 6,727 2,960 19,911,920
required after completion of the item until handing over to client and removing the same at the time of handing over.

Rates in Words:
Extra for providing special mirror finish polish on marble flooring over semi mirror polish with different grades of emery like 800, 1200, 5x. All work to be carried out
9.18 Sqm 100 115 11,500
with polishing machine.
Rates in Words:
Providing & laying machine cut single polished “Agra Red” minimum 25 mm. thick slab upto 600 mm in flooring or as per design and drawing in in normal
pattern straight or staggered joint with square or rectangular shaped stone (with grooves 10mm wide or without grooves) in cement mortar 1:6 bedding of average 35
to 50mm thickness, pointing with matching pigment and white cement in joints or filling the grooves with CM 1:2 and matching pigment, curing etc. complete. The rate
shall also include for rubbing and polishing (without scratches and marks of emeries) with different grade of emery etc. complete. The work shall be carried out as per
9.21 the approval of architect and engineer-in-charge.The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the Sqm 50 1,916 95,800
item until handing over to client and removing the same at the time of handing over.

Rates in Words:
Providing & laying 18 to 20 mm thick mirror finished granite of approved shade and quality, selected and sorted for uniform color in floor, skirting as per design
size upto 900 mm over average 40 mm thick cement mortar bedding in 1:3. (Only finished granite work shall be measured). The rate includes rounding, champhering
and mirror polishing of edges. The work shall be carried out as per the approval of architect and engineer-in-charge. The rate should include the covering & protecting
9.24.a of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of handing over. Sqm 147 3,203 470,841

Rates in Words:
Providing & laying 18 to 20 mm thick flame finished granite of approved shade and quality, seleted and sorted for uniform color in floor, skirting as per design and in
required sizes and shapes over 35 to 40 mm thick cement mortar bedding in 1:3. (Only finished granite work shall be measured). The rate includes rounding,
champhering and mirror polishing of edges. The work shall be carried out as per the approval of architect and engineer-in-charge. The rate should include the
9.24.b covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to client and removing the same at the time of Sqm 17 3,541 60,197
handing over.

Rates in Words:
Providing & laying 18 to 20 mm thick both side polished granite of approved shade and quality, seleted and sorted for uniform color for urinal, platform as per
design and in required sizes and shapes over required size of cement mortar bedding in 1:3. (Only finished granite work shall be measured). The rate includes
9.24.c rounding, champhering and mirror polishing of edges. The work shall be carried out as per the approval of architect and engineer-in-charge. Sqm 189 3,390 640,710

Rates in Words:
Cuting, Transporting and Fixing granite cobbles of size 150mm x 150mm of thickness 100mm from stones available at site as per design and drawing over 50
mm thick coarse sand bedding (cushioning layer), having compacted sub-base (in required slope and of specified thickness as per drawing - to be paid under
relevant item). Joints are to be filled with cement mortar (1:10). Sample to be approved by the Architect before executing the mass area. The work shall be carried out
as per the approval of architect and engineer-in-charge. The rate shall be inclusive of collecting the stones / boulders from anywhere within site, installing, operating
and maintaining stone cutting machine, cutting the stone as per required size and shape, transporting the finished stones to required location, providing coushion layer
9.25.b of coarse sand, fixing the granite cobbles and filling of the joints but exclusive of preparing layer of subbase. Sqm 500 480 240,000

Rates in Words:
Providing and fixing 60 mm thick abrasion resistant interlocking or Brick type paver blocks of M40 grade of approved make and colour as per design including
average 50 mm coarse sand bedding over compacted sub-base (in required slope and of specified thickness). Sample to be approved by the Architect & Engineer-in-
9.28 charge. Rate shall be exclusive of sub-base Sqm 12,376 622 7,697,872

Rates in Words:
Sr. N0. Item description Unit Quantity Rate Amount
Brick on edge flooring with bricks of class designation 75 including cement slurry, finishing the joints, flush pointing, curing etc. complete as per drawing in cement
9.29.a mortar with F.P.S. bricks. Sample shall be approved by architect and engineer-in-charge Sqm 200 456 91,200

Rates in Words:
Providing and fixing glass mosaic tiles of approved make and colour as per design in floor, dado in line, level and gradient at all levels and heights in any shape.
Chemicals or bonding material for fixing the tiles of size 25mm x 25mm shall be as per manufacturer’s specification. Grouting of the joints to be done with cement
grount of matching colour or as directed by manufacturers specification including necessary cleaning with oxalic acid. Sample of material and pattern is approved by
engineer-in-charge. The rate should include the covering & protecting of flooring with plastic + POP or as required after completion of the item until handing over to
9.33 client and removing the same at the time of handing over. Sqm 1,659 2,190 3,633,210

Rates in Words:
Providing and laying cement concrete for roads, pavements & floors 100 –150 mm. thick with machine mixed, machine vibrated M20 concrete with minimum
cement content 325 kg/cum etc. in required slope and camber as per drawing including giving a floating coat of 1:1 cement mortar, with nominal temperature steel /
weld mesh / fibers / dowel bars / tie bars at joints as specified by the Architect/Engineer-in-charge. The rate shall be exclusive of reinforcement steel, weld mesh,
fibers, dowel bars etc. and the same shall be paid in relevant tender items. Rate shall be inclusive of concrete (to be laid in alternate panels of 3.75 m X 5.5m) with
9.34.a steel channel formwork. Sieved sand shall be used Cum 3,548 4,345 15,416,060

Rates in Words:
Extra for carrying out vaccum dewatering & Power floater treatment in floors, well compacted, mechanically vibrated, finished to required levels, floated with neat
cement and power trowelled to get desired smooth finishing/broom finish, over a levelling course, including MS shuttering, curing for 10 days with gunny bags etc
complete. The suitable size of panel should be approximately 3.75 x 5.5 m or as directed by Engineer. The Construction joints to be formed at every 5m distance by
grooving with mechanical saw within 48 hrs. Groove/sawed joints shall be made of 6mm width and 25 mm depth min as shown in the drawing. The rate shall be
9.34.b inclusive of labour, grooves and machinery cost. Sqm 26,213 122 3,197,986

Rates in Words:
Providing and laying Non Cushion Synthetic Floor system of Sports Master or equivalent in 4 layers, consisting of two layer of leveling course of level master make or
equivalent and two layers of approved shade Acrylic paint and marking of lines with white paint of colour plus make or equivalent as per the manufacturer’s guideline
9.35.a in line, level and gradient to the satisfaction of Engineer-In-Charge including the cost of base course specified under section a to c below. Sqm 2,680 1,777 4,762,360

Rates in Words:
EXTRA for Synthetic floor with 6 layer cushion system, consisting of one layer of leveling course of level master make or equivalent, three cushion layer of cushion
master make or equivalent, two layers of approved shade Acrylic paint and marking of lines with white paint of colour plus make or equivalent as per the
9.35.b manufacturer’s guideline in line, level and gradient to the satisfaction of Engineer-In-Charge. Sqm 2,680 201 538,680

Rates in Words:
Providing and fixing outdoor wood floor IPE - Smooth version of size 300X300X30mm of approved make Takettt or equivalent as per manufacture’s specification.
9.38 Floor is to be laid over the polypropylene patenet grid as per manufacture’s specification and as directed by engineer in charg Sqm 1,050 5,729 6,015,450

Rates in Words:
Providing and laying in position clay tiles of size 200 mm X 80 mm as per approved sample, as per design and drawing on exterior wall as cladding. Tile is to be
fixed over 15 mm thick wired finish plaster in cement mortar 1:4 (1 cement : 4 coarse sand). Tile shall be fixed with 1:1 cement sand mortar of average 6 mm
thickness with bonding agent / integral tile adhesive of approved make of behind the tiles including keeping the groove of (5mm x 5mm) with PVC spacer of approved
make and grouting in grooves (5mm width x 5mm deep) with cementitious grout of matching shade etc. complete as directed by engineer-in-charge. Rate is inclusive
9.39 of back coat of 12 to 15 mm thick plaster with polypropelelne fibers, grouting with cementitious grout. Sqm 21,870 1,064 23,269,680

Rates in Words:
9.40 Providing & laying sandwich platform comprising of Rmt 460 5,602 2,576,920
Providing & fixing stone cladding on wall for all heights with natural finish “AGRA RED" stone, 30 mm thick having maximum size of 1200x600 mm with grooves
(10mm x 10mm) in both direction, filling the grooves with epoxy grout (10mm x 5mm) of matching shade as per detail design and drawing. The stone shall be fixed
with stainless steel clamps (304 grade) of approximate size 100x20x4mm (LxWxthick) inserted in the wall, curing etc. complete. The rate shall also include backing
coat wired finish plaster of average 15 mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) with polyproplene fibers (----gms per 1 cement bag) of approved
9.41 make, grouting the clamps in brick wall with non shrink cement mortar and anchor fasteners for RCC surfaces, etc. complete. The work shall be carried out as per the Sqm 12,728 2,614 33,270,992
cladding sample approved by Architect and engineer in charge.

Rates in Words:
Sum Carried over to Summary page 237,142,265
SECTION 10-STRUCUTRAL STEEL WORK
Structural steel work in riveted, bolted or welded in built up sections, trusses and framed work including supplying, fabricating, cutting, assembling, hoisting and fixing
in position at all heights of all shapes and size with all leads and lifts as per latest IS 4923, IS 1161, IS 806 for the work of sheds, canopy, trusses, space frame,
cladding, skylight, monkey ladder, staircase, railing, gate, insert plate, cattle trap etc. It should be including necessary rolled joists, channels, angles, tees, flats, angle
cleats, gusset plates, position hip and jack lifters, purlins, etc. including cutting and welding the members as per detailed drawing and design. The rate shall include 1
coat of Rustocap and 2 coat of Hi-Gloss Metal PU Paint of Asian paint over all the surfaces of the steel sections or as specified in the drawing. (Only standard
10.01.a measurements will be paid for as actual cut length used at site). Shop drawings for the connection details shall be prepared for the approval of the architect.

Rate shall be inclusive of cutting, wastage, welding, bending (shop at site), bolting wherever necessary, in position welding of required length, grinding, finishing
edges, filling the welded spots with metal putty. It should also include the cost of approved ISI make and size zinc coated nut-bolt and Anchor fasteners of Hilti or
Fisher as approved by engineer-in-charge

Contractor should submitted fabrications shop drawings for work involved based on construction drawings (that may be issued during construction period) for approval
by Engineer-in-charge. The fabrication work shall start after approval by Architect of the fabrication drawings. Any change required in fabrication drawings shall be
carried out at no extra cost over quoted rates. Fabrication works to be carried out as per relevant IS standards.

Rolled steel sections (equal and unequal angles, flats, angles, tees, channels, plates of different sizes etc.), Solid flats, bars chequered plate etc.
10.01.a.1 Kg 119,310 71 8,471,010

Rates in Words:
10.01.a.2 RHS, SHS, tubular hollow sections having Yst (yield strength) 310 Mpa and specified thickness as per drawing Kg 68,263 74 5,051,462
Rates in Words:
Providing, fabricating and fixing MS jali including cutting and welding the members as per detailed drawing and design and as directed by engineer-in-charge. The
rate shall include 1 coat of Rustocap and 2 coat of Hi-Gloss Metal PU Paint of Asian paint over all the surfaces or specified by engineer-in-charge of approved make
10.02 over a 2 coats of zinc chromate yellow oxide primer. (Actual measurement shall be paid for).

10.02.1 MS Weld mash jali (25mm x 25mm size of 12 guage) Sqm 100 222 22,200
Rates in Words:
10.02.2 GI Chain Link Jali (50mm x 50mm size of 10 guage) Sqm 1,080 281 303,480
Rates in Words:
Providing and fixing in position, interlocking rolling shutter of approved make, of 18 gauge, 75mm wide cold rolled MS lath interlocked, including top cover, spring,
axles, guide rails, tees, iron pulleys, bearings, handles, holding down bolts embedded in CC 1:2:4 including1 coat of Rustocap and 2 coat of Hi-Gloss Metal PU Paint
10.03 of Asian paint over all the surfaces etc. as directed. (Measurements considered for payments shall be clear size of opening plus guide channels on both the sides for
width and 450mm on top for drum height.)

10.03.1 With push and pull arrangement. Sqm 10 3,101 31,010


Rates in Words:
10.03.2 With mechanical device with a pair of handles Sqm 10 4,652 46,520
Rates in Words:
Providing and fixing in position, interlocking rolling shutter of approved make, of 18 gauge, 75mm wide cold rolled MS lath interlocked, including top cover, spring,
axles, guide rails, tees, iron pulleys, bearings, handles, holding down bolts embedded in CC 1:2:4 including 1 coat of Rustocap and 2 coat of Hi-Gloss Metal PU Paint
10.04 of Asian paint over all the surfaces etc. as directed. (Measurements considered for payments shall be clear size of opening plus guide channels on both the sides for
width and 450mm on top for drum height.)

10.04.1 Shutter shall be partly grilled and partly paneled and pull and push type. Sqm 40 3,852 154,080
Rates in Words:
10.04.2 shutter shall be partly grilled and partly paneled, mechanically operated with a pair of handles. Sqm 10 5,653 56,530
Rates in Words:
Fabricating and fixing SS railing of 304 grade made out of round pipes, square or rectangle sections in satin / brush finish with supporting fittings made out of SS
304 grade fixing with mechanical anchor fastener of stainless steel etc. on concrete surface, brick surfaces or floor including bending and bends as per the drawing
10.09 with best quality finish as per the approval of Architect and as directed by engineer-in-charge.

10.09.1 Spiral Railings Kg 3,340 539 1,800,260


Rates in Words:
10.09.2 Railings, gratings, ladder etc. Kg 3,340 539 1,800,260
Rates in Words:
Sr. N0. Item description Unit Quantity Rate Amount
Providing and fixing teak wood hand rail of the specified size and shape as per the detail design over the MS / SS fabrication and railings installed, including 3
10.10 coats PU polishing of approved make, shade etc. as directed by engineer in charge. The teak wood shall be first class Ghana teak wood. Cum 14 120,553 1,687,742

Rates in Words:
Sum Carried over to Summary page 19,424,554
SECTION 11-PAINTING WORK
White wash with lime on any surfaces (3 coats with brush) to give an even shade at all heights and all levels., including thoroughly brooming the surface to remove all
11.01.a Sqm 100 44 4,400
dirt, dust, mortar drops and other foreign matter etc. complete.
Rates in Words:
Providing and applying three coats of plastic emulsion paint of approved make, colour & shade (first two coats with brush and final coat with roller), on newly dry
interior plastered surface at all heights give an even shade, including white cement based putty of Birla white or equivalent after thoroughly brushing the surfaces free
from mortar dropping and other foreign matter and also including preparing the surface even and sand papered smooth etc. after applying every coat of putty. Priming
coat of cement primer (water or solvent based) is to be applied on putty etc. complete as directed by engineer-in-charge. Sample to be approved before starting of the
11.03.a work. The rates shall include the cost of filler for filling the cracks on surface. Sqm 82,793 113 9,355,609

Rates in Words:
Providing and applying three coats (first two coats with brush and final coat with roller) of pearl lusture paint of approved make, color & shade), on newly dry interior
plastered surface at all heights give an even shade, including white cement based putty of Birla white or equivalent after throughly brushing the surfaces free from
mortar dropping and other foreign matter and also including preparing the surface even and sand papered smooth etc. after applying every coat of putty. Priming coat
of cement primer (water or solvent based) is to be applied on putty etc. complete as directed by engineer-in-charge. Sample to be approved before starting of the
11.03.b work. The rates shall include the cost of filler for filling the cracks on surface. Sqm 45,265 144 6,518,160

Rates in Words:
Providing & applying External 100% Acrylic Paint of desired shed from Apex of Asian paint or equivalent in minimum three coats to give an even shade with brush
on exterior sand faced plastered surfaces / mala plastered surfaces or any surfaces at all heights including scaffolding, thoroughly brushing the surfaces with sand
11.05.a paper to make it free from mortar dropping and other foreign matter etc. complete as per the manufacture's specification and up to the satisfaction of Engineer in Sqm 2,427 129 313,083
charge. The rate shall also include the cost of filler for cracks on the surfaces.

Rates in Words:
Providing and applying External finish of average 1.5 to 2 mm thick acrylic polymer based texture of "Ruff & Tuff" finish of NITCO, or equivalent make with standard
tool and applicator as specified by company, on exterior surfaces at all heights including scaffolding to give even shades including througly brushing the surfaces free
from mortar droping and other foreign matter and sand papared smooth with two coats 100% Acrylic Paint etc complete as per the manufacture specifications and to
11.06 the satisfaction of Engineer In charge or architect. The rate includes making of grooves, pattas etc. and finishing. Sqm 0 407

Rates in Words:
Providing and applying solvent based Silicone paint as directed with a minimum 5 years guarantee on stamp paper to the employer directly. (The Contractor should
11.08 specify the % concentration of silicone while quoting the rate.)Minimum 7 % concentration of silicone shall be manintained while diluting with additives.

11.08.1 Exposed concrete surface Sqm 31,871 78 2,485,938


Rates in Words:
11.08.2 Exposed Brick surface Sqm 100 98 9,800
Rates in Words:
11.08.3 Clay tile cladding Sqm 21,870 98 2,143,260
Rates in Words:
11.08.4 Agra stone cladding Sqm 12,728 89 1,132,792
Rates in Words:
Providing and applying 6 mm to 8mm POP punning of JK Lakhmi Cement or equivalent over plastered surface at all levels including thoroughly brushing the surface
free from mortar dropping and other foreign matter, preparing the surface even and sand papered smooth etc. complete to receive the coat of painting as directed by
11.25 engineer in charge. Sqm 62,694 182 11,410,308

Rates in Words:
Sum Carried over to Summary page 33,373,350
SECTION 15-GENERAL DEVELOPMENT WORK
Box cutting the road surface, to proper slope and camber, for making a base for road work, including rolling, removing the excavated stuff and depositing as
15.02 directed anywhere within site, etc. complete as directed by engineer-in-charge. Cum 1,103 135 148,905

Rates in Words:
Providing and laying cast in situ RCC M20 curbing of approximate size of 40cm height X 15cm wide, including necessary excavation and backfilling, laying 75 mm
thick PCC 1:5:10 (1 part cement : 5 parts sand : 10 parts stone aggregate 20/37 mm. down size), exposed shuttering, rendering, curing, filling in the joints with rich
15.17 cement mortar but excluding reinforcement as directed etc. complete as per the details and drawings and as directed by engineer-in-charge Rmt 5,882 446 2,623,372

Rates in Words:
Providing and laying Precast RCC M20 curbing of approximate size of 60cm height x 40cm wide X 15cm thickness, including necessary excavation and backfilling,
laying 75 mm thick PCC 1:5:10 (1 part cement: 5 parts sand: 10 parts stone aggregate 20/37 mm. down size), exposed shuttering, rendering, curing and filling
15.18 bituminous mastic in expansion joints but excluding reinforcement as directed etc. complete as per the details and drawings and as directed by engineer-in-charge Rmt 12,819 665 8,524,635

Rates in Words:
Providing and laying metal soling in a compact manner for granular sub-base in single layer including supplying and spreading of large size machine cut stone
aggregates 40 mm.and down size, spreading the same in required grade and camber in one or more layer. Filling the voids with good quality murrum to make plain
15.19 surface, profusely watering including consolidating by power driven roller of 8 to 10 ton capacity in required camber, dry and wet rolling etc. complete as directed by Cum 50 1,110 55,500
engineer-in-charge.

Rates in Words:
Providing & marking 10/15 cms wide 2.5 mm thick thermoplastic patta of yellow or white on the road surface etc. comp. As. Directed. Rate includes brushing,
15.20 Sqm 420 648 272,160
brooming & cleaning and application of paint.
Rates in Words:
Providing and laying brickbat chharu over sub base including spreading in uniform layer of 50 mm thickness, consolidating with plate compacter, watering and
15.21 finishing in level and slope as shown in the drawing or as directed by Engineer-In-Charge. Sqm 10,057 56 563,192

Rates in Words:
Pitching with available stones of minimum size 150x150 mm in elevation at site in slope and floor as required according to site condition to stop erosion including
15.22 filling the joints and pointing with cement mortar 1:6 as approved by Architect and directed by engineer in charge. Rate includes dressing and cleaning of the existing Sqm 4,646 267 1,240,482
surface.
Rates in Words:

15.23 Providing & marking Zebra Crossing, Straight and turning arrows and STOP or other letters with 2.5 mm thick thermoplastic paint of yellow or white on the road Sqm 79 698 55,142
surface etc. comp. As. Directed. Rate includes brushing, brooming & cleaning and application of the paint.
Rates in Words:

15.24 Cuting, Transporting and Fixing granite cobbles curbing of size (300mm wide x 300 mm height x 150 mm thick) including necessary excavation and backfilling, Rmt 100 422 42,200
laying 75 mm thick PCC 1:5:10 (1 part cement: 5 parts sand: 10 parts stone aggregate), filling in joints with rich CM etc. complete as per the details and drawings and
as directed by engineer-in-charge. The rate shall be inclusive of collecting the stones / boulders from anywhere within site, installing, operating and maintaining stone
cutting machine, cutting the stone as per required size and shape, transporting the finished stones to required location, fixing the granite cobbles with CM, filling of the
joints, earth work and laying PCC etc. complete.
Rates in Words:

Providing and installing Textile Architecture for stadiums, stands, shoppings, logistic centres, walkways, carparking, swimming pool etc. by using FERRARI or
15.25 equivalent composite membrane made up of weave of high-tenacity polysester base yarn material of approved shade and quality by Architect and Engineer-in- Sqm 1,300 4,974 6,466,200
charge . The material should have properties like long lasting mechanical resistance, dimensional stability, flexiblity, non fading, UV resistant, flame retardant, ease of
fitting. The material shall be delivered in manufacture's original unopened containers and packaging with labels clearly identifying product name and manufacturer. It
should be stored in dry and clean indoor areas and handling in such a way to prevent damage in accordance with manufacture's instructions. Contractor shall submit
manufacturer's maintenance and cleaning manual, manufacurer's certificate etc. Work shall be executed as per the drawing in best workmanship manner upto the
satisfaction of Architect or Engineer-in-charge.
Tender Documents
Aga Khan Academy, Hyderabad

SUMMARY OF PLUMBING WORKS

Sr. No. Description Total Amount (Indian Rupees)

1 Section 01 14,481,041

2 Section 02 20,645,479

3 Section 03 4,161,815

4 Section 04 9,400,925

5 Section 05 28,055,221

Total Amount: 76,744,481

Amount in Words:

Signature of Authorised Signatory Stamp of the Bidder

Please read this Abstract in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.
Page 11 of 55
02.12.09
BILL OF QUANTITIES - PLUMBING WORKS
Sr. No. Item Description Unit Quantity Rate Amount
SECTION - 1.00

Providing and fixing galvanized iron (GI) mild steel tube (Heavy
grade Class C) of Tata make, conforming to IS: 1239, including tube
fittings of R Brand such as sockets, unions, reducers, long or short
bends, elbows, nipple, flanges, check-nuts, tees, etc., complete (in
proper line and level, with necessary supports viz., clamps of Chilly
make with m.s.brackets, RCC or brick masonry pedestals and battens,
1.01.a
if required) jointing with screw joints, using hold tight and jute for pipes
and Teflon tape for fittings and fixtures, open laid to wall, ceiling and
floor including making them good, testing and wrapping the pipes and
fittings with Hessian cloth and painting with 2 coats of approved paint
etc complete to the satisfaction of EIC of the following nominal bore
(NB) size:

1) 100 mm rmt 8 1 183 9,464


Rate in words:
2) 80 mm rmt 535 821 439,235
Rate in words:
3) 65 mm rmt 1,615 652 1,052,980
Rate in words:
4) 50 mm rmt 1,986 519 1,030,734
Rate in words:
5) 40 mm rmt 1,488 378 562,464
Rate in words:
6) 25 mm rmt 3,108 245 761,460
Rate in words:
7) 20 mm rmt 710 175 124,250
Rate in words:
8) 15 mm. rmt 3,157 139 438,823
Rate in words:

Providing and fixing galvanized iron (GI) mild steel tube (Heavy
grade Class C) of Tata make, conforming to IS: 1239, including tube
fittings of R Brand such as sockets, unions, reducers, long or short
bends, elbows, nipple, flanges, check-nuts, tees, etc., complete (in
proper line and level, with necessary supports viz., clamps of Chilly
make with m.s. brackets, RCC or brick masonry pedestals and
1.01.b
battens, if required) jointing with screw joints, using hold tight and jute
for pipes and Teflon tape for fittings and fixtures, Concealed laid to
wall, ceiling and floor including making jaries and refinished jaries,
testing and wrapping the pipes and fittings with Hessian cloth and
painting with 2 coats of approved paint etc., complete of the following
nominal bore (NB) size:

1) 100 mm rmt 0 1 183


Rate in words:
2) 80 mm rmt 0 821
Rate in words:
3) 65 mm rmt 50 652 32,600
Rate in words:
4) 50 mm rmt 46 519 23,874
Rate in words:
5) 40 mm rmt 1,361 378 514,458
Rate in words:
6) 25 mm rmt 1,776 245 435,120
Rate in words:
7) 20 mm rmt 412 175 72,100
Rate in words:
8) 15 mm. rmt 2,710 139 376,690
Rate in words:

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
12 of 55
Sr. No. Item Description Unit Quantity Rate Amount

Providing and fixing insulation to hot water open pipe on walls


with Pipe shall be wrapped around with Glass wool - Resin bonded
mattresses of rock wool min. 50 mm thick, 100 Kg/Cu.M density,
binding with 20 SWG GI chicken mesh complete covered by 24 SWG
1.03.b aluminum cladding duly screwed / rewetting etc. including all joints of
insulation foil shall be sealed with silicon sealant, end joints shall be
jointed with silicon sealant etc. Including supply, fabricating m.s.
support / clamps as per drawing etc. complete over GI lines for hot
water supply etc., complete, of the following nominal bore (NB) size

1) 40 mm rmt 97 384 37,248


Rate in words:
2) 25 mm rmt 2,306 239 551,134
Rate in words:
3) 20 mm rmt 818 315 257,670
Rate in words:
4) 15 mm. rmt 2,829 286 809,094
Rate in words:

Providing and fixing insulation to small pipes embedded in walls, with 6


mm. thick asbestos rope of Champion make or approved equivalent
1.03.c
on GI lines for Concealed hot water supply, etc complete to the
satisfaction of EIC of the following nominal bore (NB) size:

1) 40 mm rmt 0 286
Rate in words:
2) 25 mm rmt 8 204 1,632
Rate in words:
3) 20 mm rmt 412 145 59,740
Rate in words:
4) 15 mm. rmt 1,220 116 141,520
Rate in words:

Providing, fixing and testing, heavy quality gun metal or brass gate full
way wheel valve of Zoloto / Leader make with screwed/flanged ends,
1.04.a
factory tested at 20 kg/m2., on GI lines etc complete to the satisfaction
of EIC of the following nominal bore (NB) size:

1) 80 mm no. 18 6 798 122,364


Rate in words:
2) 65 mm no. 14 5 044 70,616
Rate in words:
3) 50 mm no. 101 5 283 533,583
Rate in words:
4) 40 mm no. 145 1 800 261,000
Rate in words:
5) 25 mm no. 369 1 136 419,184
Rate in words:
6) 20 mm no. 4 827 3,308
Rate in words:
7) 15 mm no. 84 588 49,392
Rate in words:

Providing, fixing and testing, heavy quality gun metal or brass non-
return swing type valve Zoloto / Leader make, with screwed/flanged
1.05.a
ends, factory tested at 20 kg/cm2.,etc complete to the satisfaction of
EIC of the following nominal bore (NB) size:

1) 25 mm no. 157 717 112,569


Rate in words:
2) 20 mm no. 4 542 2,168
Rate in words:
3) 15 mm no. 63 384 24,192
Rate in words:
Providing, fixing and testing, heavy quality gun metal or brass Air
Release Valve of Harit make, with screwed/flanged ends, factory
1.05.b
tested etc complete to the satisfaction of EIC of the following nominal
bore (NB) size:
1) 50 mm no. 5 9 418 47,090

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
13 of 55
Sr. No. Item Description Unit Quantity Rate Amount
Rate in words:
2) 25 mm no. 5 3 297 16,485
Rate in words:

Providing, fixing and testing, heavy quality gun metal or brass ball
cock heavy duty of approved make with screwed ends, factory tested
1.05.c
at 20 kg/m2., etc complete to the satisfaction of EIC on GI lines of the
following nominal bore (NB) size:

1) 80 mm no. 5 6 693 33,465


Rate in words:
2) 65 mm no. 3 5 230 15,690
Rate in words:
3) 50 mm no. 9 3 734 33,606
Rate in words:
4) 40 mm no. 32 2 185 69,920
Rate in words:
5) 25 mm no. 0 1 112
Rate in words:
6) 15 mm no. 0 542
Rate in words:

Labour charges for fixing a Water Purifier / RO plant or equivalent,


including supply and fixing 1 no. angle valve of Jaquar make
Florentine series Cat. No. 5053, with CP copper pipe inlet and outlet
1.9.a no. 121 1 200 145,200
connections, including all other electrical accessories supplied/listed by
the manufacturer, etc complete to the satisfaction of EIC and as per
the drawing/layout.

Rate in words:

Labour charges for fixing a Water Cooler, including supplying and


fixing 1 no angle valve and CP copper pipe inlet connection and GI
1.9.b no. 65 1 083 70,395
outlet pipe, including fixing electrical accessories supplied/listed by
manufacture etc complete to the satisfaction of EIC

Rate in words:

Providing and fixing in proper line and level, (including necessary


support like CI clamps, MS flats, RCC or brick masonry pedestals and
battens if required), cast iron LA class flanged end pipe of Electro
Steel Casting / Kapilanesh make, open to wall, ceiling and floor, of
approved make, including tube fittings such as sockets, reducers, long
or short bends, flanges, m.s. puddle flanges, tees etc., complete
1.16.a including making good the wall, ceiling, and floor, jointing with lead
caulked joints, testing and painting the pipes and specials with
minimum 2 coats of approved bitumastic paint over one coat of primer
etc., complete as per the specification and as directed by the
Engineer-in-charge. (RCC or brick pedestals, if any, shall be
measured and paid in the relevant tender items). The diameter of
pipe shall be of the following NB:

1) 300 mm mtr 25 7 793 194,825


Rate in words:
2) 150 mm mtr 214 3 239 693,146
Rate in words:
3) 80 mm mtr 30 1 725 51,750
Rate in words:

Providing and fixing flanged mount CI sluice valve of Zoloto /


Leader make with GM seats, high tensile brass spindle with cap,
1.17.a conforming to standard water-works pattern and flanges as per IS:
15381, flat faced and drilled, etc complete to the satisfaction of EIC
with accessories of the following pipe dia:

1) 300 mm no. 1 43 664 43,664


Rate in words:
2) 250 mm no. 2 34 005 68,010
Rate in words:
3) 200 mm no. 1 22 629 22,629
Rate in words:

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
14 of 55
Sr. No. Item Description Unit Quantity Rate Amount
4) 150 mm no. 2 12 675 25,350
Rate in words:
5) 100 mm no. 5 8 941 44,705
Rate in words:

Providing and fixing underground or below floor, high density


Polyethylene (HDPE) pipes of Hasti make Schedule PE - 80 (for
water supply purpose) and all type of fittings readymade of Hasti make
or approved moulded fabricated, including jointing using butt welding,
1.19.b
testing, etc. complete, with a working pressure of 6 Kg/m2. etc
complete to the satisfaction of EIC (Earthwork and filling, sand
filling and Concrete thurst block shall be paid extra in relevant
tender Items.) of following size :

1) 355 mm OD rmt 140 4 525 633,500


Rate in words:
2) 280 mm OD rmt 140 3 599 503,860
Rate in words:
3) 225 mm OD rmt 75 2 406 180,450
Rate in words:
4) 160 mm OD rmt 745 1 287 958,815
Rate in words:
5) 110 mm OD rmt 1,042 711 740,862
Rate in words:
6) 90 mm OD rmt 963 466 448,758
Rate in words:
7) 75 mm OD rmt 275 368 101,200
Rate in words:
8) 63 mm OD rmt 25 280 7,000
Rate in words:
Sum Carried over to Summary page 14,481,041
Section - 2.00

Providing and fixing ivory glazed vitreous chinaware extended wall


mounted cantilever type EWC of Hindustan make Cat No 20048
Crystal + 21032 with ceramic attached cistern, seat cover, cistern
fittings, CI chair bracket with rag bolt and GI 12mm rag bolt with nut
and metal washer(pair) etc including supply and fixing of 1 no CP
2.04.a no. 333 19 635 6,538,455
heavy duty angle valve with CP wall flange of Jaquar make
Florentine series Cat. No. 5053 with CP brass inlet connection with
integral `P' or `S' trap including cutting and making good the wall and
floor as under with supported on CI wall brackets etc. complete to the
satisfaction of EIC

Rate in words:

Providing and fixing Starwhite glazed vitreous chinaware Sets for


the Paraplegic of Hindustan make Cat No 70003 Matrix set-2 -
including - Wash Basin MATRIX-10060 (size 450mm x 280 mm ) with
one pair mounting brackets, EWC MATRIX-20049, Cistern ABIGAIL-
21030 complete with fittings and seat cover, one hinged rail of 76 cms,
2.04b four (4 nos) of grab rails of 60 cms and one no. of faucet for wash no. 72 30 773 2,215,656
basin with 2 no. of CP heavy duty angle valve with CP heavy flange of
Jaquar make Florentine series Cat No. 5053 with 2 nos copper
connections all required hardwares etc. complete with integral `P' or
`S' trap including cutting and making good the wall and floor etc
complete to the satisfaction of EIC

Rate in words:

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
15 of 55
Sr. No. Item Description Unit Quantity Rate Amount

Providing and fixing ivory glazed vitreous chinaware wash basin


of Hindustan make with single or double hole for pillar-tap comprising
of: a) Ivory glazed vitreous chinaware washbasin, with supporting MS
or CI brackets. b) 1 no. 40 or 32mm CP cast brass bottle-trap of
Jaquar make Allied series Cat. No. 769 with extension piece to wall,
wall flange with rubber adopter for waste connection and one waste
2.08a
coupling. c) 1 no. heavy quality CP brass angle valve with wall CP
flange of Jaquar make Florentine series Cat. No. 5053, 15mm size.
d) 1 no. 15mm NB heavy quality CP-brass inlet connection with unions
at end. The supporting bracket shall be painted with 3 coats of
approved paint of approved shade etc. complete to the satisfaction of
EIC in following size:

i) 560 mm x 450 mm - Hindustan make Cat. No. 10008 VIKING no. 30 4 100 123,000

Rate in words:
ii) 630 mm x 500 mm (oval-under counter type). - Hindustan make
no. 124 6 483 803,892
Cat. No. 10045 RAPHSODY
Rate in words:

Providing and fixing Ivory glazed vitreous chinaware wash basin


of Hindustan make with single or double hole for pillar-tap comprising
of: a) Ivory glazed vitreous chinaware washbasin, with supporting MS
or CI brackets. b) 1 no. 40 or 32mm CP cast brass bottle-trap of
Jaquar make Allied series Cat. No. 769 with extension piece to wall,
wall flange with rubber adopter for waste connection and one waste
2.08b
coupling. c) 2 nos. heavy quality CP brass angle valves with wall CP
flange of Jaquar make Florentine series Cat. No. 5053, 15mm size.
d) 2 nos. 15mm NB heavy quality CP-brass inlet connection with
unions at end. The supporting bracket shall be painted with 3 coats of
approved paint of approved shade etc. complete to the satisfaction of
EIC. in following size:

i) 560 mm x 450 mm - Hindustan make Cat. No. 10008 VIKING no. 99 4 229 418,671

Rate in words:
ii) 630 mm x 500 mm (oval-under counter type). - Hindustan make
no. 174 6 757 1,175,718
Cat. No. 10045 RAPHSODY
Rate in words:

Providing and fixing a stainless steel sink of Nirali make, single


bowl of size not more than 610 mm x 460 mm and depth 254 mm,
comprising of: a) stainless steel sink supported on MS or CI brackets.
b) 1 no. 40 or 32mm CP cast brass bottle-trap of Jaquar make Allied
series Cat. No. 769 with extension piece to wall, wall flange with
2.10.a. rubber adopter for waste connection and one waste coupling. c) 1 no. no. 76 12 827 974,852
heavy quality CP brass angle valves with wall CP flange of Jaquar
make Florentine series Cat. No. 5053 15 mm size. d) 1 no. 15 mm
NB heavy quality CP-brass inlet connection with unions at end. The
supporting bracket shall be painted with 3 coats of approved paint of
approved shade etc. complete to the satisfaction of EIC

Rate in words:

Providing and fixing a stainless steel sink of Nirali make, single


bowl with drain board of overall size 1000 mm x 510 mm and depth
175 mm, comprising of: a) stainless steel sink supported on MS or CI
brackets. b) 1 no. 40 or 32mm CP cast brass bottle-trap of Jaquar
make Allied series Cat. No. 769 with extension piece to wall, wall
flange with rubber adopter for waste connection and one waste
2.10.b. no. 41 11 568 474,288
coupling. c) 1 no. heavy quality CP brass angle valves with wall CP
flange of Jaquar make Florentine series Cat. No. 5053 15 mm size.
d) 1 no. 15 mm NB heavy quality CP-brass inlet connection with
unions at end. The supporting bracket shall be painted with 3 coats of
approved paint of approved shade etc. complete to the satisfaction of
EIC

Rate in words:

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
16 of 55
Sr. No. Item Description Unit Quantity Rate Amount

Providing and fixing screw down brass chromium plated heavy


quality bib-tap of Jaquar make Florentine series Cat. No. 5037 on
2.11.a no. 369 862 318,078
water supply pipe lines of 15mm dia with or without extension piece
but with a flange etc. complete to the satisfaction of EIC

Rate in words:

Providing and fixing, screw down brass chromium plated long body
bib taps, of Jaquar make Continental series Cat. No. 107 heavy
2.11.b no. 24 815 19,560
quality, of approved make, on GI lines, of 15 mm. dia., with or without
extension piece and flange etc complete to the satisfaction of EIC

Rate in words:

Providing and fixing brass chromium plated heavy quality pillar-


tap/cock of Jaquar make Florentine series Cat No. 5011 on water
2.12.a no. 111 903 100,233
supply pipelines of 15mm dia with or without extension piece but with a
flange etc complete to the satisfaction of EIC

Rate in words:
Providing and fixing brass chromium plated heavy quality wash
basin mixer pillar-tap/cock of Jaquar make Florentine series Cat
2.13.a No. 5167 on water supply pipelines of 15mm dia with or without no. 286 2 691 769,626
extension piece but with a flange, etc., complete to the satisfaction of
EIC.
Rate in words:

Providing and fixing brass chromium plated heavy quality Wash


basin sensor of Jaquar make series Cat No. 51021 on water supply
2.13.b no. 43 9 174 394,482
pipelines of 15mm dia with or without extension piece but with a
flange, etc., complete to the satisfaction of EIC

Rate in words:
Providing and fixing 15mm NB CP brass heavy quality wall or floor
mounted sink tap, swivel type, with CP wall flange, casted spout of
2.14 no. 125 1 334 166,750
Jaquar make Florentine series Cat. No. 5357 etc. complete to the
satisfaction of EIC
Rate in words:

Providing and fixing best Indian make mirror of specified size like
Modi float, Sain Gobin, I.A.G or equivalent silvered locally, with plain
edge as required, with 12mm thick marine plywood backing, with CP
2.15 sqm 355 693 246,015
brass caps, etc., complete. Teakwood beading of 20mm x 32mm size,
with French polish or 3 coats of paint etc. complete to the satisfaction
of EIC

Rate in words:
Providing and fixing a CP brass Towel-ring of Jaquar make
Continental series Cat. No. 1121 with concealed type brackets fixed
2.16.b no. 436 740 322,640
to the wall with CP brass screws, etc., complete to the satisfaction of
EIC
Rate in words:
Providing and fixing a CP towel-rack, 230 x 600mm size of Jaquar
make Continental accessories Cat. 1181 with concealed type
2.16.c no. 269 2 458 661,202
brackets fixed to the wall with CP brass screws, etc., complete to the
satisfaction of EIC
Rate in words:

Providing and fixing SS or brass chromium plated double Robe


2.16.d hook of Jaquar make Continental series Cat. 1161 as per the no. 378 560 211,680
design and specifications, etc., complete to the satisfaction of EIC

Rate in words:

Providing and fixing a screw-to-wall type toilet paper-roll holder


2.17.b fixed to the wall with CP brass screws, of Jaquar make Continental no. 378 909 343,602
series Cat. No. 1153 complete to the satisfaction of EIC

Rate in words:

Providing and fixing soap dispenser of Jaquar make Continental


series Cat. No. 1137 metallic liquid soap dispenser with SS pump, cap
2.18.a no. 436 1 410 614,760
and CP heavy duty bracket, fixed to wall with CP brass screw, etc.,
complete to the satisfaction of EIC

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
17 of 55
Sr. No. Item Description Unit Quantity Rate Amount
Rate in words:

Providing and fixing a surface type soap dish / tray of Jaquar


2.18.c make Continental series Cat. No. 1131 complete with clean surface no. 273 856 233,688
to original conditions, etc., complete to the satisfaction of EIC

Rate in words:
Providing and fixing a heavy quality CP brass stopcock
(concealed with sheet flange) of 15mm dia. of Jaquar make Cat.
2.19.b.2 no. 31 1 060 32,860
No. 5083 on water supply pipe lines etc. complete to the satisfaction
of EIC

Providing and fixing a heavy quality CP brass angular stopcock


of Jaquar make Florentine series Cat. No. 5053 (male or female
2.19.c.1 no. 84 838 70,392
end) of 15mm dia on water supply pipe lines etc. complete to the
satisfaction of EIC
Rate in words:
Providing and fixing a 15mm dia inlet pressure adjustable shower
rose with cast shower arm of size 230 mm and flange of Jaquar make
2.20.a no. 203 1 439 292,117
Florentine series Cat No. 5489 etc. complete to the satisfaction of
EIC
Rate in words:
Providing and fixing Telephone shower with 1.5 Mtr long flexible
tube swivel wall hook inclusive of all accessories, etc complete of
2.20.b no. 70 1 753 122,710
Jaquar make Florentine series Cat. No. 5537 etc. complete to the
satisfaction of EIC
Rate in words:
Providing and fixing Bath Tub Mixer wall or table top mounted
with Telephone shower arrangement for Bath Tub with all accessories
2.21.a such as CP heavy duty flange etc complete of Jaquar make no. 70 3 274 229,180
Florentine series Cat. No. 5271 or 5267 etc complete to the
satisfaction of EIC
Rate in words:
Providing and fixing Hot & Cold wall mixer with provision for
overhead shower with 115 mm long bend pipe with all accessories,
2.21.b no. 172 2 790 479,880
flange etc complete of Jaquar make Florentine series Cat. No. 5273
etc. complete to the satisfaction of EIC
Rate in words:

Providing and fixing a vitreous chinaware ivory urinal of


Hindustan make Cat. No. 60010 DYNA with all accessories, including
supply and installation of 1 no. of heavy duty CP Urinal sensor with
2.22 no. 52 13 135 683,020
wall plate complete of Jaquar make Cat. No. 51087 with necessary
connection etc. complete to the satisfaction of EIC in size mentioned
under :

Rate in words:

Providing and fixing bath tub of Hindware make "TIFFANY" of size


1670 x 755 x 470 mm including CP heavy duty waste coupling,
2.35.a overflow connecting with 32mm dia copper pipe up to P trap, including no. 8 11 713 93,704
all necessary cutting, fixing, brackets etc complete to the satisfaction of
EIC (For Guest House and Principal Bungalow)

Rate in words:

Providing and fixing bath tub of Hindware make "IRIS" of size


1520 x 730 x 465 mm including CP heavy duty waste coupling,
2.35.b overflow connecting with 32mm dia GI pipe up to P trap, including all no. 62 11 470 711,140
necessary cutting, fixing, brackets etc complete to the satisfaction of
EIC (For Student Residences and Faculty Residences)

Rate in words:
Providing and fixing Hand Shower (Health Faucet) of Jaquar
make Allied series Cat. No. 573 with angle valve of Jaquar make
2.39 Florentine series Cat. No 5053 with CP flange with 8 mm dia., 1 m no. 378 2 126 803,628
long PVC tube and wall hook of approved make etc. complete to the
satisfaction of EIC
Rate in words:
Sum Carried over to Summary page 20,645,479
Section - 3.00

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
18 of 55
Sr. No. Item Description Unit Quantity Rate Amount

Providing and fixing in position a Stainless steel grating, 150mm x


150mm or 150mm dia / square in size, of Chilly make Cat. No. SS006
3.04.a no. 885 169 149,565
generally conforming to the drawings and fixed on the inlet pipe etc
complete to the satisfaction of EIC

Rate in words:
Providing and fixing in position PVC rain water inlets with gravel
guard grating of Supreme / Prince make conforming to drawings
3.05.a no. 123 641 78,843
and fixed on the inlet of 160 mm dia pipe etc complete to the
satisfaction of EIC
Rate in words:
Providing and fixing in position PVC rain water inlets with gravel
guard grating of Supreme / Prince make conforming to drawings
3.05.b no. 300 396 118,800
and fixed on the inlet of 110 mm dia pipe etc complete to the
satisfaction of EIC
Rate in words:

Providing and fixing, to wall, ceiling and floor, SWR quality, heavy
duty, 6 Kg/cm² working pressure PVC pipes, of Supreme / Prince
make, open laid, for Soil / Waste / Rain water etc complete, jointing
with rubbering and airtight joints, with necessary specials, bends, such
3.08.a as `Y' junction, `T' junction (both single and double), including plugs,
shoes, cowls, flange compression type fittings, wall clips, etc. and
lubricant or jointing material, including testing, cutting, making good the
wall, ceiling and floor, etc complete to the satisfaction of EIC , The dia.
of pipes shall be of the following outer diameter(OD):

1) 160 mm (RWP) rmt 1,161 576 668,736


Rate in words:
2) 110 mm rmt 2,832 331 937,392
Rate in words:
3) 90 mm rmt 691 227 156,857
Rate in words:

Providing and fixing Rigid PVC quality, 6kg /cm² of Supreme /


Prince make concealed laid with necessary specials, bends, such as
`Y' junction, `T' junction (both single and double), including plugs,
shoes, cowls, flange compression type fittings, wall clips, in proper line
and level with necessary support like brackets (hot dip galvanized
3.08.b 35X5mm flat) / clamps of chilly make with 3 mm minimum thickness,
RCC or brick pedestals or battens, if necessary, to wall, ceiling and
floor, open, complete jointing with solvent cement and airtight joints,
with ‘T’ shaped rubber ring, , etc., and lubricant or jointing material,
including testing, cutting, making good the wall, ceiling and floor, etc
complete to the satisfaction of EIC of the following OD

1) 160 mm (RWP) rmt 60 752 45,120


Rate in words:
2) 110 mm rmt 3,871 384 1,486,464
Rate in words:
3) 90 mm rmt 574 251 144,074
Rate in words:
Providing and fixing an SWR quality, heavy duty, uPVC ‘P’ trap of
Prince / Supreme make Including cutting the floor and making them
3.09.a good with surrounding M15 CC, masonry supports, MS brackets etc. no. 822 419 344,418
testing, etc complete to the satisfaction of EIC having 110 mm inlet
and 110 mm outlet.
Rate in words:
Providing and fixing an SWR quality, heavy duty, uPVC Nahni trap of
Prince / Supreme make Including cutting the floor and making them
3.09.b good with surrounding M15 CC, masonry supports, MS brackets etc. no. 62 303 18,786
testing, etc complete to the satisfaction of EIC having 110 mm inlet
and 110 mm outlet.
Rate in words:

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
19 of 55
Sr. No. Item Description Unit Quantity Rate Amount

Supply and fixing of stainless steel mosquito proof jali with required
3.10 fittings for over flow pipe of over head tank as per the requirement and no. 110 116 12,760
drawings etc complete to the satisfaction of EIC

Rate in words:
Sum Carried over to Summary page 4,161,815
Section - 4.00

Providing and laying salt glazed stone-ware pipes of 230 mm


diameter (to the level and slope) and jointing with stiff mixture of CM
1:1, at a depth from1.5 m to 3.0 m including testing of pipes and
4.01.a.2 joints, etc. ( Necessary civil work like, excavation, refilling rmt 0 699
trenches, formwork, B.B.C.C, etc., shall be carried out, measured
and paid in the relevant tender items of civil works) complete to
the satisfaction of EIC

Rate in words:

Providing and laying salt glazed stone-ware pipes of 150 mm


diameter (to the level and slope) and jointing with stiff mixture of CM
1:1, at a depth upto 1.5 m including testing of pipes and joints, etc.,
4.01.b.1 ( Necessary civil work like, excavation, refilling trenches, rmt 22 396 8,712
formwork, B.B.C.C, etc., shall be carried out, measured and paid
in the relevant tender items of civil works) complete to the
satisfaction of EIC

Rate in words:

Providing and laying salt glazed stone-ware pipes of 100 mm


diameter (to level and slopes) and jointing with stiff mixture of CM 1:1,
upto 1.5 m depth including testing of pipes and joints, etc.,
4.01.c.1 ( Necessary civil work like, excavation, refilling trenches, rmt 290 221 64,090
formwork, B.B.C.C, etc., shall be carried out, measured and paid
in the relevant tender items of civil works) complete to the
satisfaction of EIC

Rate in words:

Providing and fixing a salt-glazed stoneware gully trap, class `A'


of 150 mm dia inlet and 100 mm outlet with CI grating at the top, etc
complete to the satisfaction of EIC (Necessary civil work like;
4.03.b no. 228 582 132,696
excavation, CC 1:2:4, brick masonry, plastering etc., shall be
carried out, measured and paid in the relevant tender items of
civil works).

Rate in words:

Providing and fixing a salt-glazed stoneware gully trap, class `A'


of 230 mm dia inlet and 150 mm outlet with CI grating at the top,etc
complete to the satisfaction of EIC (Necessary civil work like;
4.03.c no. 2 1 142 2,284
excavation, CC 1:2:4, brick masonry, plastering etc., shall be
carried out, measured and paid in the relevant tender items of
civil works).

Rate in words:

Providing and laying in trench reinforced concrete non-pressure IS


class NP-2 pipes of 600 mm internal diameter at a depth upto 1.5 m
on RCC cradle if specified (to the level and slope) and jointing with
collars and butt-ends prepared for collar joints, including filling the
4.05.a.1 joints with CM 1:1 and testing of joints, etc., The rates also excludes rmt 114 1 625 185,250
necessary excavation and filling of trenches etc complete to the
satisfaction of EIC (RCC cradle and excavation, backfilling shall be
measured and paid paid in the relevant tender items of civil
works).

Rate in words:

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
20 of 55
Sr. No. Item Description Unit Quantity Rate Amount

Providing and laying in trench reinforced concrete non-pressure IS


class NP-2 pipes of 600 mm internal diameter at a depth from 1.5 m
to 3 m on RCC cradle if specified (to the level and slope) and jointing
with collars and butt-ends prepared for collar joints, including filling the
4.05.a.2 joints with CM 1:1 and testing of joints, etc., The rates also excludes rmt 0 1 625
necessary excavation and filling of trenches etc complete to the
satisfaction of EIC (RCC cradle and excavation, backfilling shall be
measured and paid paid in the relevant tender items of civil
works).

Rate in words:

Providing and laying in trench reinforced concrete non-pressure IS


class NP-2 pipes of 450 mm internal diameter at a depth upto 1.5 m
on RCC cradle if specified (to the level and slope) and jointing with
collars and butt-ends prepared for collar joints, including filling the
4.05.b.1 joints with CM 1:1 and testing of joints, etc., The rates also excludes rmt 304 1 066 324,064
necessary excavation and filling of trenches etc complete to the
satisfaction of EIC (RCC cradle and excavation, backfilling shall be
measured and paid paid in the relevant tender items of civil
works).

Rate in words:

Providing and laying in trench reinforced concrete non-pressure IS


class NP-2 pipes of 450 mm internal diameter at a depth from 1.5 m
to 3 m on RCC cradle if specified (to the level and slope) and jointing
with collars and butt-ends prepared for collar joints, including filling the
4.05.b.2 joints with CM 1:1 and testing of joints, etc., The rates also excludes rmt 0 1 048
necessary excavation and filling of trenches etc complete to the
satisfaction of EIC (RCC cradle and excavation, backfilling shall be
measured and paid paid in the relevant tender items of civil
works).

Rate in words:

Providing and laying in trench reinforced concrete non-pressure IS


class NP-2 pipes of 300 mm internal diameter at a depth up to 1.5 m
on RCC cradle if specified (to the level and slope) and jointing with
collars and butt-ends prepared for collar joints, including filling the
4.05.c.1 joints with CM 1:1 and testing of joints, etc., The rates also excludes rmt 780 979 763,620
necessary excavation and filling of trenches etc complete to the
satisfaction of EIC (RCC cradle and excavation, backfilling shall be
measured and paid paid in the relevant tender items of civil
works).

Rate in words:

Providing and laying in trench reinforced concrete non-pressure IS


class NP-2 pipes of 300 mm internal diameter at a depth from 1.5 m
to 3 m on RCC cradle if specified (to the level and slope) and jointing
with collars and butt-ends prepared for collar joints, including filling the
4.05.c.2 joints with CM 1:1 and testing of joints, etc., The rates also excludes rmt 900 856 770,400
necessary excavation and filling of trenches etc complete to the
satisfaction of EIC (RCC cradle and excavation, backfilling shall be
measured and paid paid in the relevant tender items of civil
works).

Rate in words:

Providing and laying in trench reinforced concrete non-pressure IS


class NP-2 pipes of 230 mm internal diameter at a depth up to 1.5 m
on RCC cradle if specified (to the level and slope) and jointing with
collars and butt-ends prepared for collar joints, including filling the
4.05.d.1 joints with CM 1:1 and testing of joints, etc., The rates also excludes rmt 1,924 466 896,584
necessary excavation and filling of trenches etc complete to the
satisfaction of EIC (RCC cradle and excavation, backfilling shall be
measured and paid paid in the relevant tender items of civil
works).

Rate in words:

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
21 of 55
Sr. No. Item Description Unit Quantity Rate Amount

Providing and laying in trench reinforced concrete non-pressure IS


class NP-2 pipes of 230 mm internal diameter at a depth from 1.5 m
to 3 m on RCC cradle if specified (to the level and slope) and jointing
with collars and butt-ends prepared for collar joints, including filling the
4.05.d.2 joints with CM 1:1 and testing of joints, etc., The rates also excludes rmt 968 454 439,472
necessary excavation and filling of trenches etc complete to the
satisfaction of EIC (RCC cradle and excavation, backfilling shall be
measured and paid paid in the relevant tender items of civil
works).

Rate in words:

Providing and laying in trench reinforced concrete non-pressure IS


class NP-2 pipes of 150 mm internal diameter up to 1.5 m depth on
RCC cradle if specified (to the level and slope) and jointing with
collars and butt-ends prepared for collar joints; including filling the
4.05.e.1 joints with CM 1:1 and testing them etc., The rates also excludes rmt 1,769 268 474,092
necessary excavation and filling of trenches etc complete to the
satisfaction of EIC (RCC cradle and excavation, backfilling shall be
measured and paid paid in the relevant tender items of civil
works).

Rate in words:

Providing and fixing a cast iron grating frame and cover of


specified clear size, shape and weight of NECO make including
4.06.b.1 kg 38,504 129 4,967,016
carting from store to site of work, fixing in CC and finishing with 3 coats
of anti-corrosive paint etc complete to the satisfaction of EIC.

Rate in words:
Providing and fixing, CI steps in manhole, water tank, septic tank,
etc., of size 385 mm x 150 mm x 25 mm and painting with 3 coats of
4.09 no. 1,521 245 372,645
anti-corrosive paint, etc complete to the satisfaction of EIC (NECO
make)
Rate in words:
Sum Carried over to Summary page 9,400,925
SECTION - 5.0
Solar System : (300 Lts / day) Consisting following - Make : Sola Hart
5.01.a Job 58 164,674 9,551,092
made in Australia Model No. 302J
Rate in words:

Supplying, storing, handling, erecting, testing and commissioning of


Solar water heating system complete with Collectors, Tank, Pressure
and temperature relief valve as mentioned bellow.Each system is
required to be fitted with Aluminum stand which should be design to
withstand max wind velocity of 140 km/hr. System should be pressured
indirect heating system and including inbuilt appropriate electrical
backup .

Tank specification - Each unit consist of 300 ltrs storage tank with
compress puf insulation and ceramic lining from inside. Tank should be
fitted with sacrifical anode and soft flow stratifier for batte drain down
capacity. Pressure withstand capacity of each tank should be 15Kg /
cm2 and test pressure at 25 Kg/cm2

Collector specification - Each unit consist of 35 Riser an pressure


withstand capacity of collector is min 10 Kg/cm2. It should be capable
of handling indirect heating fluid.
Hot water Circulating Pump - Make : Grundfos model No. UPS 15-
14 BUT 80 with inbuilt timer and thermostat system
Rate in words:
Solar System : (180 Lts / day) Consisting following - Make : Sola
5.01.b Job 54 119,646 6,460,884
Hart made in Australia Model No. 181J
Rate in words:

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
22 of 55
Sr. No. Item Description Unit Quantity Rate Amount

Supplying, storing, handling, erecting, testing and commissioning of


Solar water heating system complete with Collectors, Tank, Pressure
and temperature relief valve as mentioned bellow.Each system is
required to be fitted with Aluminum stand which should be design to
withstand max wind velocity of 140 km/hr. System should be pressured
indirect heating system and including inbuilt appropriate electrical
backup .

Tank specification - Each unit consist of 180 ltrs storage tank with
compress puf insulation and ceramic lining from inside. Tank should be
fitted with sacrifical anode and soft flow stratifier for batte drain down
capacity. Pressure withstand capacity of each tank should be 15Kg /
cm2 and test pressure at 25 Kg/cm2

Collector specification - Each unit consist of 35 Riser an pressure


withstand capacity of collector is min 10 Kg/cm2. It should be capable
of handling indirect heating fluid.
Hot water Circulating Pump - Make : Grundfos model No. UPS 15-
14 BUT 80 with inbuilt timer and thermostat system
Supply, testing and commissioning of following size water cooler with
5.02.a all required hardwares etc. complete as per the direction of EIC - Blue
Star make
1) 120 Lts. Storage, 80 Lts / hour cooling capacity Model No.
no 13 50,211 652,743
SDIx8120
Rate in words:

2) 80 Lts. Storage, 40 Lts / hour cooling capacity Model No. SDIx480 no 52 36,847 1,916,044

Rate in words: 0

Supply, erection, testing and commissioning of water Softening plant


of consisting followings, The supplier / Contractor shall submit the
5.03 Job 1 562,068 562,068
Technical Data Sheet along with the bid. Makes : Jay Pumps / Ion
Exchange or Approved equivalent

Rate in words:
- Type : Downflow 0
- Output/Reg.Base on 350PPM : 300 M3/Regeneration 0
- Max. Flow Rate Lts / Hr. : 40 M3 / Hr. 0
- Salt Required / Regeneration : 270 Kg 0
- Max. Working Pressure : 2 - 2.5 Kg / CM2 0
- Treated water hardness : Less than 50-100 PPM as CaCo3 0
- Duration of Regeneration : 75 Minutes 0
Softener Vessel : MS / FRP 0
Resin : Cation Resins / Ion Exchange 0
Resin : Quantities 1800 - 2000 Lts 0
Raw water pump : Grundfos / Kirlosker make including 1 stand by
0
pump duly fully automatic valve / operating
Supply, erection, testing and commissioning of R.O. Water plant of
followings size : The supplier / Contractor shall submit the Technical
5.04
Data Sheet along with the bid. Makes : Jay Pumps / Ion Exchange
or Approved equivalent
1) 50 Lts / Hour Capacity Job 65 56,831 3,694,015
Rate in words: 0
- Skid : SS Frame 0
- Pre Filter : 20" x 2.5" x 20 Micron PP Filter USA 0
- Carbon Filter : 20" Activated carbon block filter 0
- Booster pump : 235 PSI pressure (2 Nos) 0
- Membrane : 75 GPD (5 Nos) 0
- Post carbon filter : 2 Nos. 0
- Water rejection : Less then 50 % 0
- Auto flushing : Solenoid valve 0
- Automatic ON / OFF : Floating switch 0
- Pressure gauge meter : Approved quality 0

- Indicator : Power, Working, Low pressure, Auto flushing, Tank Full 0

- TDS Rejection : 90 to 95 % 0
2) 10 Lts / Hour Capacity Job 70 16,862 1,180,340
Rate in words: 0

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
23 of 55
Sr. No. Item Description Unit Quantity Rate Amount
- Skid : SS Frame 0
- Pre Filter : 10" x 5" x 20 Micron PP Filter USA 0
- Carbon Filter : 10" Activated carbon block filter 0
- Booster pump : 80 PSI pressure (2 Nos) 0
- Membrane : 75 GPD 0
- Post carbon filter : 0
- Water rejection : Less then 60 % 0
- Auto flushing : Solenoid valve 0
- Automatic ON / OFF : Floating switch 0
- Pressure gauge meter : Approved quality 0

- Indicator : Power, Working, Low pressure, Auto flushing, Tank Full 0

Supply, erection, testing and commissioning of following pump sets


5.05 0
complete as per the direction of EIC.

1) Water supply Pump : 850 LPM @ 25 M head, with required


electrical cords from starter panel to pump including L & T make Motor
starter panel of appropriate capacity including liquid level controller Set 2 94,447 188,894
with necessary sensor with required wiring etc complete to the
satisfaction of EIC : Pump model No NB 40 - 160 / 172 of Grundfos

Rate in words: 0

2) Drainage Pump : 5 Cu.M / Hour @ 20 M head, with required


electrical cords from starter panel to pump including Control panel of
approved make. Motor protection starter panel of appropriate capacity
Set 2 143,067 286,134
including inbuilt automatic pump operating system with necessary
sensor with required wiring etc complete to the satisfaction of EIC :
Pump model No SEG 40.15. with Grinder system

Rate in words:

Supply, erection, testing and commissioning of 300 Cu.M per Day RBC
based compact sewage treatment plant to match following parameters.
The system produces very little sludge– and that too in a completely
mineralized form convertible into garden compos. Including required
civil foundations / base pad, plumbing works, necessary electrification
with required strters/ panel for fully atomization. Refer the details
specification in the tender. (Excavation, PCC, RCC pump / Machine
foundations, bk. work, plaster, backfilling shall be measured and paid
for separately in relevant civil items).
5.06 JOB 1 3,563,007 3,563,007
It should match local pollution board land discharge norms. Also, the
contractor shall submit P & I diagram and tentative layout showing
overall size for space requirement alongwith offer. The overall hight of
plant shall not be exceed 3 mts from finished ground level and with
minimum area occupancy.
Make: Thermex / Naik Environmental Engineers Pvt. Ltd. The
supplier / Contractor shall submit the Technical Data Sheet along
with the bid.

Rate in words:
Sum Carried over to Summary page 28,055,221

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
24 of 55
Tender Documents
Aga Khan Academy, Hyderabad

SUMMARY OF ELECTRICAL WORKS

Sr. No. Description Total Amount (Indian Rupees)

2 HT Breaker 1,710,125

3 Transformer 5,775,699

4 Busduct 1,345,635

5 Substation Equipment & Substation Auxiliary 617,098

6 MV Switchgear & Power Panels 11,818,870

7 DG set 7,011,437

8 Distribution Board 3,898,710

9 Cable Trench 4,061,250

10 Cables 32,458,615

11 Cable Termination 645,261

12 Cable Tray 1,836,900

14 Internal Wiring 14,318,905

15 Light Fixtures & Fans 38,411,520

16 Earthing 2,726,223

17 Telephone And Data Distribution 5,665,099

18 Miscellaneous 213,793

19 External Lighting 31,749,744

20 Television Distribution 638,067

Total Amount: 164,902,951

Amount in Words:

Signature of Authorised Signatory Stamp of the Bidder

Please read this Abstract in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 25 of 55
BILL OF QUANTITIES - ELECTRICAL WORKS
Sr. No. Item Description Unit Quantity Rate Amount
2.0 HT breaker

Supplying, Testing & Commissioning of HT VCB panel consisting of 1


no. of 400A HT VCB as incoming and 3 nos of 400A HT VCB as
2.1 outgoing. The panel should have tinned copper busbars and extensible No. 1 1,710,125 1,710,125
type for future requirements. The Panel should be complete with
metering and protection as per specification.

Sub Total 2.0..... 1,710,125


3.0 Transformer
Supplying, Testing, Commissioning & unloading at site, shifting to the
erection site assembling, leveling, grouting, installing and
3.1 No. 3 1,925,233 5,775,699
commissioning of Dry Type cast resin Transformer with on load tape
chagner and RTCC panel of 750 KVA
Sub Total 3.0..... 5,775,699
4.0 Busduct

Supplying, assembling, grouting in slab with hanging rods/ strips, water


proof, dust proof, vermin proof busduct to be fabricated out of 14
gauge sheet. The busduct should be processed through 7 tank
process. The busduct should be powder coated. All joints should be
fitted with neoprene gasket. The busduct should confirm to IP 43
4.1 45 29,903 1,345,635
protection.The capacity of the busbar should be four pole 1200A amp
and should be of tinned EC grade Cu material, with necessary flexible
bends. Necessary certificate shall be required at the time of
supply.The capacity of neutral bus should be equal to phase bus.
(INDOOR DUTY)

Sub Total 4.0..... 1,345,635


5.0 Substation Equipment & Substation Auxiliary
SITC of 11 KV, 3 core Al. 240 sqmm H.T. XLPE armoured unearth
5.1 Rmt. 60 1,225 73,500
cable
SITC of H.T. cable indoor type end connection for 11 KV XLPE, 240
5.2 No. 8 12,864 102,912
sq mm x 3 core cable
Supplying & Erecting conventional type Carbon Dioxide fire
5.3 No. 3 6,344 19,032
extinguishers of ISI approved of 3.2 kgs
Supplying & Erecting conventional tyep Carbon Dioxide fire
5.4 No. 3 6,779 20,337
extinguishers of ISI approved of 5.0 kgs

Suppplying & Erecting automatic emergency light with maintenance


5.5 No. 10 1,166 11,660
free battery for 20 watts tube. With exide make battery

Supplying & Erecting Rubber mat 1.1 KV grade ISI marked 1000 x
5.6 No. 25 750 18,750
2000 x 6 mm size.
Supplying & Erecting Rubber mat 11 KV grade ISI marked 1000 x
5.7 No. 5 1,419 7,095
2000 x 12 mm size.
Providing and erecting danger notice board for medium voltage
5.8 installation to be erected as per I.S. The board should be 150 x 150 No. 12 121 1,452
mm.
Providing and erecting danger notice board for high voltage installation
5.9 No. 6 150 900
to be erected as per I.S.
Providing printed instruction chart both in English & REGIONAL
5.10 LANGUAGE & duly framed out on glass for treatment of person No. 8 415 3,320
suffering from Electric shock.
Providing pair of rubber hand gloves suitable for working on 11 KV/22
5.11 No. 2 506 1,012
KV supply.
5.12 Supplying Standard First aid box with all the Standard contents. No. 2 1,085 2,170

Supplying GI bucket round bottom duly painted 13 Ltrs. capacity &


5.13 No. 8 306 2,448
filled with dry sand & kept on stand provided on stand or wall hook.

Supplying & Erecting 1.5 mtr. (5') x 0.9 mtr. (3.1') x 0.6 mtr. (2.1')
Floor mounted stand (For keeping 4 Nos.of buckets) made of 30 x 30 x
5.14 No. 2 1,265 2,530
4 mm. angle iron welded with 4 hooks and duly painted with one coat
of red lead & two coats of Approved enameled silver paints.

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 26 of 55
Sr. No. Item Description Unit Quantity Rate Amount
Wall hooks of 22 to 25 cms. projection for keeping fire buckets made
5.15 out of 15 mm. dia M.S. rod grouted in wall to a depth of minimum 15 No. 8 135 1,080
cms.

Preparing necessary drawing submitting to authorities, getting their


approval / senction and final certificate to energize the sub-station
5.16 equipment’s.Filling the necessary application to supply co. following up LS 1 348,900 348,900
and getting the supply filling the necessary test report to the supply co.
inclusive. All official / statutory fees shall be paid by clients.

Sub Total 5.0..... 617,098


6.0 MV Switchgear & Power Panels

Supplying, unloading at site, shifting to site, assembling, leveling,


grouting, erecting, Testing, & Commissioning of L.T. panel board,
6.1
fabricated from CRCA sheet & folded channel totally enclosed cubical
type compartmentalized as per drawings.

6.1.1 Main Panel of Academy building No. 1 477,191 477,191


as per attached Single Line Diagram
6.1.2 Lighting Panel of Academy building No. 3 33,687 101,061
as per attached Single Line Diagram
6.1.3 Computer Panel of Academy Building No. 1 33,754 33,754
as per attached Single Line Diagram
6.1.4 Main AC Panel of Academy Building No. 1 245,704 245,704
as per attached Single Line Diagram
6.1.5 Emergency Panel C No. 1 53,368 53,368
as per attached Single Line Diagram
6.1.6 Main Panel of SR-7-8 No. 4 56,152 224,608
as per attached Single Line Diagram
6.1.7 Emergency Panel of SR 7-8 No. 4 17,173 68,692
as per attached Single Line Diagram
6.1.8 Solar Panel of SR 7-8 No. 4 10,103 40,412
as per attached Single Line Diagram
6.1.9 Main Panel of SR 9-10 No. 2 73,946 147,892
as per attached Single Line Diagram
6.1.10 Emergency Panel of SR 9-10 No. 2 19,594 39,188
as per attached Single Line Diagram
6.1.11 Solar Panel of SR 9-10 No. 2 15,357 30,714
as per attached Single Line Diagram
6.1.12 Main Panel of SR 11-12 No. 2 153,474 306,948
as per attached Single Line Diagram
6.1.13 Emergency Panel of SR 11-12 No. 2 20,441 40,882
as per attached Single Line Diagram
6.1.14 Solar Panel of SR 11-12 No. 2 15,357 30,714
as per attached Single Line Diagram
6.1.15 Main Panel of Principal's Bunglow No. 1 32,547 32,547
as per attached Single Line Diagram
6.1.16 Emergency Panel of Pricipal's bunglow No. 1 7,870 7,870
as per attached Single Line Diagram
6.1.17 Solar Panel of Pricipal's bunglow No. 1 10,044 10,044
as per attached Single Line Diagram
6.1.18 Main Panel of Nursery No. 1 40,415 40,415
as per attached Single Line Diagram
6.1.19 Emergency Panel of Nursery No. 1 8,328 8,328
as per attached Single Line Diagram
6.1.20 Main Panel of Junior Academy No. 1 175,264 175,264
as per attached Single Line Diagram
6.1.21 Emergency Panel of Junior Academy No. 1 22,696 22,696
as per attached Single Line Diagram
6.1.22 Main Computer Panel of Junior Acdemy No. 1 10,648 10,648
as per attached Single Line Diagram
6.1.23 Sub LT Panel of Junior Academy ( Library) No. 1 96,220 96,220
as per attached Single Line Diagram
6.1.24 Sub LT Panel of Junior Academy ( Laboratry) No. 1 54,578 54,578
as per attached Single Line Diagram
6.1.25 Main Panel of Guest House No. 1 75,278 75,278
as per attached Single Line Diagram

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 27 of 55
Sr. No. Item Description Unit Quantity Rate Amount
6.1.26 Emergency Panel of Guest House No. 1 9,512 9,512
as per attached Single Line Diagram
6.1.27 Solar Panel of Guest House No. 1 13,523 13,523
as per attached Single Line Diagram
6.1.28 Main Panel of Student Longue No. 1 40,899 40,899
as per attached Single Line Diagram
6.1.29 Main Panel of Senior Academy No. 1 214,540 214,540
as per attached Single Line Diagram
6.1.30 Lighitng Panel of Senior Academy No. 1 78,305 78,305
as per attached Single Line Diagram
6.1.31 Computer Panel of Academy Building No. 1 16,945 16,945
as per attached Single Line Diagram
6.1.32 Emergency Panel of Senior Academy No. 1 11,967 11,967
as per attached Single Line Diagram
6.1.33 Sub LT Panel of senior Academy for lab No. 1 101,909 101,909
as per attached Single Line Diagram
6.1.34 Main Panel of Athletic centre No. 1 170,421 170,421
as per attached Single Line Diagram
6.1.35 Main Panel of Athletic centre- squash Building No. 1 43,321 43,321
as per attached Single Line Diagram
6.1.36 AC Panel of Athletic centre No. 1 82,057 82,057
as per attached Single Line Diagram
6.1.37 Emergency Panel of Athletic centre No. 1 11,747 11,747
as per attached Single Line Diagram
6.1.38 Main Panel of Health & Wellness centre No. 1 38,115 38,115
as per attached Single Line Diagram
6.1.39 Main Panel of Seminar block of Senoir Academy No. 1 64,020 64,020
as per attached Single Line Diagram
6.1.40 Emergency Panel of Seminar Block of Senior Academy No. 1 10,053 10,053
as per attached Single Line Diagram
6.1.41 Main Panel of Mech. Workshop No. 42,831
as per attached Single Line Diagram
6.1.42 Main Panel of common( Dinning) No. 1 226,645 226,645
as per attached Single Line Diagram
6.1.43 Emergency Panel of common( Dinning) No. 1 55,910 55,910
as per attached Single Line Diagram
6.1.44 AC Panel of common( Dinning) No. 1 143,430 143,430
as per attached Single Line Diagram
6.1.45 Main LT Panel for Transformer :1 No. 1 1,115,851 1,115,851
as per attached Single Line Diagram
6.1.46 Main LT Panel for Transformer :2 No. 1 1,406,669 1,406,669
as per attached Single Line Diagram
6.1.47 Main LT Panel for Transformer :3 No. 1 1,383,641 1,383,641
as per attached Single Line Diagram

1200A FP ACB Bus coupler with electrical and mechanical


6.1.48 No. 2 280,852 561,704
interlock with encloser having same size same as main LT panels.

as per attached Single Line Diagram


6.1.49 Main Emergency Panel No. 1 891,170 891,170
as per attached Single Line Diagram
6.1.50 Emergency Panel A No. 1 39,820 39,820
as per attached Single Line Diagram
6.1.51 Emergency Panel B No. 1 39,820 39,820
as per attached Single Line Diagram
6.1.52 Emergency Panel D No. 1 104,209 104,209
as per attached Single Line Diagram
6.1.53 Emergency Panel E No. 1 36,055 36,055
as per attached Single Line Diagram
6.1.54 Faculty Residence Cluster 1 No. 1 254,537 254,537
as per attached Single Line Diagram
6.1.55 Faculty Residence Cluster 2 No. 1 254,537 254,537
as per attached Single Line Diagram
6.1.56 Faculty Residence Cluster 3 No. 1 193,960 193,960
as per attached Single Line Diagram
6.1.57 Faculty Residence Cluster 4 No. 1 286,549 286,549
as per attached Single Line Diagram

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 28 of 55
Sr. No. Item Description Unit Quantity Rate Amount
6.1.58 Plumbing panel -1 No. 1 46,226 46,226
as per attached Single Line Diagram
6.1.59 Plumbing panel -2 No. 1 46,226 46,226
as per attached Single Line Diagram
6.1.60 300 KVAR APFCR Panel No. 3 483,187 1,449,561
as per attached Single Line Diagram
Sub Total 6.0..… 11,818,870
7.0 DG set

Supplying, installation, testing and commissioning of DG set of


725/750 KVA with approximate 890 BHP engine & suitable alternator
complete with all necessary fuel piping,Aluminium cladding, exhaust
piping, control panel, AMF Panel, silencer & its piping, Acoustic
silencer, Alternator cable termination box suitable for Aluminium
7.1 No. 1 7,011,437 7,011,437
cables,initial battery charging,base frame, battery and charger
complete in all respect. Scope also includes preparing necessary
drawing submitting to authorities, getting their approval / sanction and
final certificate including NOC from pollution board(if required) to
energize the D G Set .

Sub Total 7.0..… 7,011,437


8.0 Distribution Board

Supplying, assembling, grouting, levelling, installation, Connecting &


testing D.B of specified make but without MCB / ELMCB/MCCB etc but
with all internal busbar as per requirement.

8.1 TPN Distribution Board :

Supplying, erecting, testing and commissioning of only TPN D.B. with


space for FPMCB as incoming and space for DPELMCB and 12
8.1.1 No. 25 5,388 134,700
SPMCB as outgoing per phase (i.e. 16 way TPN D.B.) eqequivalent to
MDS cat no 607719 with 16 way PPI kit cat no.607894

Supplying, erecting, testing and commissioning of only TPN D.B. with


space for FPMCB as incoming and space for DPELMCB and 8
8.1.2 No. 80 4,422 353,760
SPMCB as outgoing per phase (i.e. 12 way TPN D.B.) eqequivalent to
MDS cat no 607718 with 12 way PPI kit cat no.607893

Supplying, erecting, testing and commissioning of only TPN D.B. with


space for FPMCB as incoming and space for DPELMCB and 4
8.1.3 No. 107 3,275 350,425
SPMCB as outgoing per phase (i.e. 8 way TPN D.B.) eqequivalent to
MDS cat no 607717 with 8 way PPI kit cat no.607892

Supplying, erecting, testing and commissioning of only TPN D.B. with


space for FPMCB as incoming and space for 3 no. FPMCB as
8.1.4 No. 27 2,379 64,233
outgoing(i.e. 4 way TPN D.B.) equivalent to MDS cat no 607715 with
necessary busbar link)
8.2 SPN Distribution Board

Supplying, erecting, testing and commissioning of SPN D.B. with


8.2.1 space for DPELMCB as incoming and 12 SPMCB as outgoing per No. 1 1,713 1,713
phase (i.e. 16 way SPN D.B.) equivalent to MDS cat no. 607713

Supplying, erecting, testing and commissioning of SPN D.B. with


8.2.2 space for DPELMCB as incoming and 8 SPMCB as outgoing per No. 3 1,413 4,239
phase (i.e. 12 way SPN D.B.) equivalent to MDS cat no. 607712

Supplying, erecting, testing and commissioning of SPN D.B. with


8.2.3 space for DPELMCB as incoming and 4 SPMCB as outgoing per No. 89 850 75,650
phase (i.e. 8 way D.B.) equivalent to MDS cat no. 607711

Supplying, erecting, testing and commissioning of SPN D.B. suitable


for outdoor mounting IP 65 with space for DPMCB as incoming and 4
8.2.4 No. 73 1,517 110,741
SPMCB as outgoing (i.e. 6 way SPN D.B.) equivalent to Hensel make
cat no. KV 7106

Supplying, erecting, testing and commissioning of SPN D.B. suitable


for outdoor mounting IP 65 with space for DPMCB as incoming and 2
8.2.5 No. 171 1,320 225,720
SPMCB as outgoing (i.e. 4 way SPN D.B.) equivalent to Hensel make
cat no. KV 7104
8.3 VTPN Distribution Board

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 29 of 55
Sr. No. Item Description Unit Quantity Rate Amount
Supplying,erecting, testing and commissioning of only VTPN D.B.
8.3.1 having suitable space for 250 A FP MCCB as incomer and 12 TP No. 12,578
MCBs as outgoing equivalent to MDS cat no 607822
Supplying,erecting, testing and commissioning of only VTPN D.B.
8.3.2 having suitable space 125 A FP MCCB as incomer and 12 TP MCBs No. 2 9,259 18,518
as outgoing equivalent to MDS cat no 607792
Supplying,erecting, testing and commissioning of only VTPN D.B.
8.3.3 having suitable space for 125 A FP MCCB as incomer and 8 TP MCBs No. 2 7,278 14,556
as outgoing equivalent to MDS cat no 607791
Supplying,erecting, testing and commissioning of only VTPN D.B.
8.3.4 having suitable space for 125 A FP MCCB as incomer and 4 TP MCBs No. 1 5,771 5,771
as outgoing equivalent to MDS cat no 607790

Supplying,erecting, testing and commissioning of only VTPN D.B.


8.3.5 having suitable space for 63 A FP MCB as incomer and 8 TP MCBs as No. 4 6,355 25,420
outgoing equivalent to MDS cat no 607751
Supplying,erecting, testing and commissioning of only VTPN D.B.
8.3.6 having suitable space for 32 A FP MCB as incomer and 4 TP MCBs as No. 5,252
outgoing equivalent to MDS cat no 607750
8.4 MCB 's and its Accessories
Supplying, Assembling, levelling, connecting & testing following MCB /
ELMCB / Isolators etc in boards as specified in 8.1, 8.2.
8.4.1 6 to 32 A SP MCB No. 4,863 134 651,642
8.4.2 6 to 32 A DP MCB No. 4 374 1,496
8.4.3 40 A DP Isolator No. 201 250 50,250
8.4.4 40/63 A FP Isolator No. 61 566 34,526
8.4.5 6 A DP ELMCB(ELCB+MCB) (30mA) No. 2 1,522 3,044
8.4.6 16 A DP ELMCB(ELCB+MCB) (30mA) No. 46 1,487 68,402
8.4.7 32 A DP ELMCB(ELCB+MCB) (30mA) No. 335 1,615 541,025
8.4.8 32 A DP ELMCB(ELCB+MCB) (100mA) No. 94 1,798 169,012
8.4.9 40 A DP ELMCB(ELCB+MCB) (30mA) No. 36 1,888 67,968
8.4.10 40 A DP ELMCB(ELCB+MCB) (100mA) No. 87 2,010 174,870
8.4.11 63 A DP ELMCB(ELCB+MCB) (30mA) No. 21 2,190 45,990
8.4.12 63 A DP ELMCB(ELCB+MCB) (100mA) No. 114 2,305 262,770
8.4.13 32 A TP MCB No. 36 595 21,420
8.4.14 40 A TP MCB No. 4 900 3,600
8.4.15 63 A TP MCB No. 4 900 3,600
8.4.16 32 A FP MCB No. 173 786 135,978
8.4.17 40 A FP MCB No. 47 1,148 53,956
8.4.18 63 A FP MCB No. 85 1,148 97,580
8.4.19 Sheet steel metal enclouser for SP MCB cat no.607881 No. 244
8.4.20 Sheet steel metal enclouser for DP MCB cat no.607882 No. 13 316 4,108
8.4.21 Sheet steel metal enclouser for FP MCB cat no.607884 No. 41 362 14,842
8.4.22 Blank Plates No. 450 14 6,300
8.5 MCCBs:
Supplying, Assembling, levelling, connecting & testing following
MCCB etc in boards as specified in 8.1, 8.2.
8.5.1 100 A FP MCCB not less than 10 KA No. 4 4,568 18,272
8.5.2 125 A FP MCCB not less than 10 KA No. 1 4,874 4,874
8.5.3 160 A FP MCCB not less than 16 KA No. 1 14,856 14,856
8.5.4 250 A FP MCCB not less than 25 KA No. 1 14,790 14,790
8.6 Caution Board :
Caution boards of size 150 x 150 mm. to be supplied & fixed on the
8.6.1 No. 243 151 36,693
D.B.
Caution boards of size 100 x 100 mm. to be supplied & fixed on the
8.6.2 No. 100 114 11,400
D.B.
Sub Total 8.0..... 3,898,710
9 Cable Trench

Excavation and back filling of cable trenches required for laying the
cables directly buried in the ground. This includes supplying and
9.1 RMt 4,275
providing cable markers at an interval of 10 meters. The depth shall be
app. 0.7mtr and the width shall be as per requirement.

Supplying and spreading fine sand for a thickness of 100 mm. and
9.2 providing and laying bricks for protection on cable on all the three RMt 14,250 285 4,061,250
sides.
Sub Total 9.0..... 4,061,250

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 30 of 55
Sr. No. Item Description Unit Quantity Rate Amount
10 Cables

Supply, testing and Laying XLPE steel/GI wire/flat armoured cable of


1100 V grade of Aluminum / Copper Conductor of following sizes in
ready made trench or mounted on wall with necessary clamping
arrangement or in pre-laid RCC hume pipe with necessary cable
identification mark to be provided at distance of 10 mt. The vertical
cable on wall shall be drawn in prelaid conduit for vertical mechanical
support.

Aluminium Cables
10.1 400 Sq.mm x 3.5C Al. Cable RMt 17,973 851 15,295,023
10.2 300 Sq.mm x 3.5C Al. Cable RMt 8,715 685 5,969,775
10.3 240 Sq.mm x 3.5C Al. Cable RMt 5,840 565 3,299,600
10.4 185 Sq.mm x 3.5C Al. Cable RMt 2,953 451 1,331,803
10.5 150 Sq.mm x 3.5C Al. Cable RMt 100 406 40,600
10.6 120 Sq.mm x 3.5C Al. Cable RMt 793 329 260,897
10.7 95 Sq.mm x 3.5C Al. Cable RMt 1,636 272 444,992
10.8 70 Sq.mm x 3.5C Al. Cable RMt 815 215 175,225
10.9 50 Sq.mm x 3.5C Al. Cable RMt 1,334 170 226,780
10.10 35 Sq.mm x 3.5C Al. Cable RMt 1,150 131 150,650
10.11 25 Sq.mm x 4C Al. Cable RMt 165 135 22,275
Copper Cables
10.12 16 Sq.mm x 4C Cu. Cable RMt 930 304 282,720
10.13 10 Sq.mm x 4C Cu. Cable RMt 8,975 212 1,902,700
10.14 6 Sq.mm x 4c Cu. Cable RMt 8,735 148 1,292,780
10.15 4 Sq.mm x 4c Cu. Cable RMt 7,645 113 863,885
10.16 2.5 Sq.mm x 4c Cu. Cable RMt 2,374 80 189,920
10.17 6 Sq.mm x 3c Cu. Cable RMt 100 129 12,900
10.18 4 Sq.mm x 3c Cu. Cable RMt 5,280 91 480,480
10.19 2.5 Sq.mm x 3c Cu. Cable RMt 2,085 66 137,610
10.20 1.5 Sq.mm x 3c Cu. Cable RMt 1,560 50 78,000
Sub Total 10.0..... 32,458,615
11 Cable Termination

Supplying & fixing single compression type Brass glands (single


compression for indoor application and double compression for
outdoor applications) & making joint with necessary bi metalic crimping
socket of long nack type connecting the same to various
equipment/panel/DB etc. for the following sizes:

Aluminium Cables
11.1 400 Sq.mm x 3.5C Al. Cable No. 54 2,585 139,590
11.2 300 Sq.mm x 3.5C Al. Cable No. 48 2,033 97,584
11.3 240 Sq.mm x 3.5C Al. Cable No. 28 1,745 48,860
11.4 185 Sq.mm x 3.5C Al. Cable No. 16 1,351 21,616
11.5 150 Sq.mm x 3.5C Al. Cable No. 4 1,340 5,360
11.6 120 Sq.mm x 3.5C Al. Cable No. 6 1,304 7,824
11.7 95 Sq.mm x 3.5C Al. Cable No. 8 1,112 8,896
11.8 70 Sq.mm x 3.5C Al. Cable No. 8 878 7,024
11.9 50 Sq.mm x 3.5C Al. Cable No. 22 234 5,148
11.10 35 Sq.mm x 3.5C Al. Cable No. 16 200 3,200
11.11 25 Sq.mm x 4C Al. Cable No. 16 171 2,736
Copper Cables
11.12 16 Sq.mm x 4c Cu. Cable No. 18 183 3,294
11.13 10 Sq.mm x 4c Cu. Cable No. 391 141 55,131
11.14 6 Sq.mm x 4c Cu. Cable No. 600 127 76,200
11.15 4 sq.mm x 4 c Cu. No. 511 120 61,320
11.16 2.5 sq.mm x 4 c Cu. No. 168 92 15,456
11.17 6 Sq.mm x 3c Cu. Cable No. 6 115 690
11.18 4 Sq.mm x 3c Cu. Cable No. 542 110 59,620
11.19 2.5 Sq.mm x 3c Cu. Cable No. 176 77 13,552
11.20 1.5 Sq.mm x 3c Cu. Cable No. 160 76 12,160
Sub Total 11.0..... 645,261
12 Cable Tray
Supply & Installation of hot dip GI ladder type cable tray with all
accessories like coupler, GI nut bolts,bend, tee, reduser etc as
12.1
per specification and drawings complete with all required
hardware :

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 31 of 55
Sr. No. Item Description Unit Quantity Rate Amount
12.1.1 150 x 50 made out of 2 mm thick RMt 970 317 307,490
12.1.2 300 x 100 made out of 2 mm thick RMt 1,250 480 600,000
12.1.3 450 x 100 made out of 2 mm thick RMt 345 531 183,195
12.1.4 600 x 100 made out of 2 mm thick RMt 270 594 160,380
Supply & Installation of hot dip GI Perforated type cable tray with
all accessories like coupler, GI nut bolts,bend, tee, reduser etc as
12.2
per specification and drawings complete with all required
hardware :
12.2.1 150 x 50 made out of 2 mm thick RMt 145 371 53,795
12.2.2 300 x 100 made out of 2 mm thick RMt 390 654 255,060
12.2.3 450 x 100 made out of 2 mm thick RMt 100 851 85,100
12.2.4 600 x 100 made out of 2 mm thick RMt 180 1,066 191,880
Sub Total 12.0..... 1,836,900
14 Internal Wiring

Wiring of points to be done in open/concealed manner in 25 mm dia


medium guage Rigid PVC FRLS pipe. Wiring shall be done with FRLS
type copper flexible wire of 650V/1100V. Separate pipe should be
taken for circuit mains. Nos of ciruit of the same phases may be taken
in same conduit (maximum 2 ckts).The circuit shall be laid in 25/40
14.1
mm dia medium guage rigid PVC FRLS pipe.The point rate shall
include all the necessary piping and wiring from sub panel /
Distribution board to switch board & switch board to the batten holder /
angle holder / connector / ceiling rose all inclusive except sub panel /
Dist board.

The wiring shall be done as per relevant prevailing standard. The


looping of the wiring should be done in the switch boxes or light and
fan point outlet boxes to avoid the junction boxes. The junction boxes
and switch boxes for the ceiling light point, fan point etc shall be
minimum 60/75 deep. All the necessary jarry in brick plastered walls
should be done with machine cutter only , also jarry should be filled
with cement, sand and wire mesh as required, the material cost for
rough finish shall be included in point rate.Whenever pipes are
required to be laid in flooring shall be of heavy guage.Wiring should be
done as per distribtion details. Each circuit should have dedicated
phase, neutral & earth wire. Wire sizes to be used as under

For Light Points /fan point/ wall fan / 6A 3 Pin Plug

- DB to SB - 2.5sqmm for Phase & Neutral & 1.5 sqmm for Earth

- SB to Point - 1.5 sqmm for Phase & Neutral & Earth


For 6A plug point
-  1.5 sqmm for Phase, Neutral & Earth
For 6/10/16A general purpose plug point
- 2.5 sqmm for Phase, Neutral & 1.5 sq. mm Earth
For 16A plug point for A/C and Geyser
- 4 sqmm for Phase, Neutral & 2.5 sq. mm Earth
For 20/32A plug point
- 6 sqmm for Phases, Neutral & 4 sq. mm Earth
No zarry will be allowed in expose brick work. The conduit shall be
provided when the walls are under construction. The pipes in slab shall
be laid before the slab is casted.
14.1.1 One light point controlled by one single way 6 A switch. No. 4,189 944 3,954,416
14.1.2 Loop light point to be controlled from same switch. No. 2,835 249 705,915
14.1.3 One light point controlled by two, two way 6 A switch No. 509 1,093 556,337
One ceiling fan outlet point controlled by one 6 A switch and hum free
14.1.4 No. 1,092 952 1,039,584
electronic type step regulator.
One 6 A x 5 pin 250 Volt socket outlet point controlled by one 6 A
14.1.5 No. 1,826 221 403,546
switch located on switch board.

14.1.6 6 A x 5 pin 250 Volt switched socket outlet point at convenient location. No. 577 597 344,469

6/16 A x 250 V switch socket point on one switch box. (Approx two
14.1.7 No. 690 1,085 748,650
points in one circuits)
14.1.8 6/16A x 250 Volt switched socket outlet point for A.C./Geyser. No. 70 1,817 127,190
14.1.9 -Do- as above but switch and socket at different location. No. 6 2,061 12,366
Exhaust fan outlet point with 6A 5 pin socket controlled by one 5 single
14.1.10 No. 305 926 282,430
way switch located at different location.

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 32 of 55
Sr. No. Item Description Unit Quantity Rate Amount

14.1.11 10A x 250V Metal clad socket outlet point with 10 Amp. SPMCB. No. 12 925 11,100

14.1.13 20 A x 250 Volt metal clad socket outlet point with 20 Amp. SPMCB. No. 15 1,000 15,000

32 A 5 pin x 415 Volt (3 Phase) Metal clad socket outlet point with 32
14.1.14 No. 12 3,555 42,660
Amp. FPMCB.

16 A x 250 V plug & socket with interlocked switched socket, DP MCB


14.1.15 and surface mounting box IP 66 with DIN rail for 2 module equivalent No. 11 5,149 56,639
to legrand make Cat no.56661 but without cost of wiring and piping.

32 A x 250 V plug & socket with interlocked switched socket, DP MCB


14.1.16 and surface mounting box IP 66 with DIN rail for 5 module equivalent No. 3 6,088 18,264
to legrand make Cat no.56669 but without cost of wiring and piping.

32 A x 415 V plug & socket with interlocked switched socket, FP MCB


14.1.17 and surface mounting box IP 66 with DIN rail for 5 module equivalent No. 6 7,727 46,362
to legrand make Cat no.56674 but without cost of wiring and piping.

Buzzer point controlled by Bell push with modular type buzzer same
14.1.18 No. 90 1,053 94,770
make as switch

14.1.19 Bell point controlled by Bell push switch with bell of approved make. No. 70 950 66,500

SITC computer power supply point with 2 nos of 6 amp 5 pin plugs
14.1.20 with 1 no. of 16 Amp. Plug with 1 no 16 A Switch with indicator & No. 795 1,013 805,335
wiring of computer point.
14.2 MAINS :
The mains is considered from the meter/sub panel to the individual
distribution boards.

Supplying and Laying mains with 4 nos. of 25 sq mm Cu. PVC


insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and
2 nos 10 sqmm Cu. PVC insulated flexible wires with ISI approval for
14.2.1 Rmtr 1,057
650 V/ 1100 V as earth wires to be drawn in 50 mm diameter rigid PVC
conduit of medium guage having ISI and FIA approval with all
necessary accessories.

Supplying and Laying mains with 4 nos. of 16 sq mm Cu. PVC


insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and
2 nos 6 sqmm Cu. PVC insulated flexible wires with ISI approval for
14.2.2 Rmtr 2,070 545 1,128,150
650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC
conduit of medium guage having ISI and FIA approval with all
necessary accessories.

Supplying and Providing mains with 4 nos. of 10 sq mm Cu. PVC


insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and
2 nos 4 sqmm Cu. PVC insulated flexible wires with ISI approval for
14.2.3 Rmtr 1,185 399 472,815
650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC
conduit of medium guage having ISI and FIA approval with all
necessary accessories.

Supplying and Providing mains with 4 nos. of 6 sq mm Cu. PVC


insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and
2 nos 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for
14.2.4 Rmtr 4,226 254 1,073,404
650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC
conduit of medium guage having ISI and FIA approval with all
necessary accessories.

Supplying and Laying mains with 2 nos. of 10 sq mm Cu. PVC


insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and
1 no 6.0 sqmm Cu. PVC insulated flexible wires with ISI approval for
14.2.5 Rmtr 990 227 224,730
650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC
conduit of medium guage having ISI amd FIA approval with all
necessary accessories.

Supplying and Providing mains with 2 nos. of 6 sq mm Cu. PVC


insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and
1 nos 4.0 sqmm Cu. PVC insulated flexible wires with ISI approval for
14.2.6 Rmtr 8,420 133 1,119,860
650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC
conduit of medium guage having ISI and FIA approval with all
necessary accessories.

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 33 of 55
Sr. No. Item Description Unit Quantity Rate Amount

Supplying and Providing mains with 3 nos. of 4 sq mm Cu. PVC


insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and
14.2.7 Rmtr 1,152 114 131,328
be drawn in 25 mm diameter rigid PVC conduit of medium guage
having ISI and FIA approval with all necessary accessories.

Supplying and Providing mains with 3 nos. of 2.5 sq mm Cu. PVC


insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and
14.2.8 Rmtr 99
be drawn in 25 mm diameter rigid PVC conduit of medium guage
having ISI and FIA approval with all necessary accessories.

Supplying and Providing mains with 3 nos. of 1.5 sq mm Cu. PVC


insulated flexible wire with ISI and FIA approval for 650 V/ 1100 V and
14.2.9 Rmtr 70
be drawn in 25 mm diameter rigid PVC conduit of medium guage
having ISI and FIA approval with all necessary accessories.

14.3 Race way


Supply and installation of 3 compatement 225 mm x 38 mm under floor
metal trunking/race way with all accessories made out of hot dip pre
14.3.1 Rmtr 485 813 394,305
galvanized metal coated steel sheet equivalent to MK Ega (novar)
make.

Supply and installation of 1 compatement 100 mm x 38 mm under floor


metal trunking/race way with all accessories made out of hot dip pre
14.3.2 Rmtr 75 480 36,000
galvanized metal coated steel sheet equivalent to MK Ega (Novar)
make.

Supply and installation of 3 compartment Access outlet / service box of


250 x 250 x 60-75 mm with all accessories made out of high pressure
14.3.3 Rmtr 55 4,318 237,490
die cast material suitable for above race ways equivalent to MK Ega
(Novar) make.

Supply and installation of 3 compatement 100 mm x 50 mm wall


14.3.4 trunking/race way with cover and all accessories made out of PVC Rmtr 270 627 169,290
equivalent to MK (premier) make.
Sub Total 14.0..... 14,318,905
15 Light Fixtures & Fans
Supplying, erecting, connecting, testing and commissioning of
Following type Light Fixture with all necessary Hardware, Internal
15.1
Wiring with Lamp,Ballast etc. all required accessories Complete in all
respect.
15.1.1 Light Fixture Type A with basic rate as specified separately No. 3,862 3,693 14,262,366
15.1.2 Light Fixture Type B with basic rate as specified separately No. 3,672 5,528 20,298,816
Presence detector for lighting control non regulating type high
performance having detection area not less than 6 mtr dia at 2.4 mt ht.
15.1.3 No. 110 6,056 666,160
equivalent to wipro make MS 1200PFmkII complete in all repect with
necessary wiring.

Presence detector for analogue dimmable ballast regulating type high


performance having detection area not less than 6 mtr dia at 2.4 mt ht.
15.1.4 No. 67 8,225 551,075
equivalent to wipro make MS 2001AF complete in all repect with
necessary wiring.
Supply,Installation, testing and commissioning following sizes ceiling
15.2
Fans without fan regulator.
36/42" Dia Sweep Ceiling Fan with Fan Hook as per approved colour &
15.2.1 No. 80 1,627 130,160
equivalent to crompton make high speed type...
48" Dia Sweep Ceiling Fan with Fan Hook as per approved colour &
15.2.2 No. 961 1,528 1,468,408
equivalent to crompton make high speed type...
56" Dia Sweep Ceiling Fan with Fan Hook as per approved colour &
15.2.3 No. 48 1,915 91,920
equivalent to crompton make high speed type...

Additional fan rod made out of 10 guage GI pipe with all necessary
15.2.4 No. 598 105 62,790
painted and required accessories for fan suspention.

Supply, Installation,testing and commissioning of following sizes


15.3
Exhaust Fans of approved make
Light duty 225/305 mm. diameter propeller exhaust fans single phase
15.3.1 No. 167 1,969 328,823
1400 RPM.
Heavy duty 305 mm. diameter propeller exhaust fans single phase
15.3.2 No. 83 2,207 183,181
1400 RPM.
Heavy duty 450 mm. diameter propeller exhaust fans single phase
15.3.3 No. 57 6,453 367,821
1400 RPM. With M.S. louvre shutter of the exhaust fan

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 34 of 55
Sr. No. Item Description Unit Quantity Rate Amount
Sub Total 15.0..... 38,411,520
16 Earthing
Providing earthing stations for equipment earthing as shown and
16.1
specified in drawing for equipment complete with :
16.1.1 600 x 600 x 6.15 mm cu.plate No. 8 18,165 145,320
16.1.2 600 x 600 x 3.15 mm cu.plate No. 99 13,049 1,291,851
16.1.3 450 x 450 x 3.15 mm cu.plate No. 5 12,046 60,230
16.2 Earth wire/strips :
Supply and laying cu. earthing required size strips for interconnecting
the earthing stations, panels, DB's etc. in built up trenches, on
walls/ceiling, buried in ground generally as specified and shown on
drawings complete with :
a) Fixing accessories.
b) Corrosion protection of buried conductors with bituminous coating
and covered with PVC tapes.
16.2.1 25 x 3 mm cu. strip Rmtr 2,125 306 650,250
16.2.2 32 x 6 mm cu. strip Rmtr 160 772 123,520
16.2.3 50 x 6 mm cu. strip Rmtr 160 1,208 193,280
16.2.4 No.8 gauge bare cu. earth wire Rmtr 3,365 56 188,440
Earth Link : 38mm x 6 mm 1ft Long Cu.earth link fixed by necessary
16.2.5 No. 108 679 73,332
screws on wall.
Sub Total 16.0..... 2,726,223
17 Telephone And Data Distribution

Supply, installation, connection, testing and commissioning of


telephone and data network system.The unit rate considered on
running meter basis includes supply, laying, connection, testing and
commissioning of multipair telephone/data cables through rigid PVC
conduit from tag block/HUB of each block to MDF located in the data
room/near EPABX system. The telephone cable shall be installed in a
concealed manner in the vertical riser including supply & fixing tag
block with KRONE type terminal Junction box of specified make.

17.1 PVC Conduits


Supply & laying of 25 mm dia. Open/conceal manner heavy guage
17.1.1 Rmtr 25,530 43 1,097,790
rigid PVC pipe.
Supply & laying of 40 mm dia. Open/conceal manner heavy guage
17.1.2 Rmtr 100 90 9,000
rigid PVC pipe.
17.2 Cabling

Supplying and Laying of 0.5 mm dia Annealed copper 5 pair armoured


17.2.1 telephone cable where ever required in prelaid conduit or clampped in Rmtr 160 80 12,800
open manner or clampped in open manner

Supplying and Laying of 0.5 mm dia Annealed copper 10 pair


17.2.2 armoured telephone cable where ever required in prelaid conduit or Rmtr 2,810 104 292,240
clampped in open manner.
Supplying and Laying of 0.5 mm dia Annealed copper 20 pair
17.2.3 armoured telephone cable where ever required in prelaid conduit or Rmtr 2,160 134 289,440
clampped in open manner.
Supplying and Laying of 0.5 mm dia Annealed copper 50 pair
17.2.4 armoured telephone cable where ever required in prelaid conduit or Rmtr 1,465 248 363,320
clampped in open manner.
Supplying and Laying of 0.5 mm dia Annealed copper 100 pair
17.2.5 armoured telephone cable where ever required in prelaid conduit or Rmtr 1,860 497 924,420
clampped in open manner.
Supplying and Laying of 0.5 mm dia Annealed copper 200 pair
17.2.6 armoured telephone cable where ever required in prelaid conduit or Rmtr 50 962 48,100
clampped in open manner.

Supplying and Laying outdoor 24 count armoured fiber cable for


computer Data connectivity equivalent to systimax make teraspeed
17.2.7 7,300 90 657,000
plenum code no 5125 024A WPBK having appx outside diameter of 11
mm where ever required in prelaid conduit or in open manner.

17.3 Tag Blocks


Supply & fixing of 10 pair tagblock with KRONE with fabricated CRCA
17.3.1 powder coated junction box of size 120x170x100 with two no. of pad- No. 77 822 63,294
lock.

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 35 of 55
Sr. No. Item Description Unit Quantity Rate Amount
Supply & fixing of 20 pair tagblock with KRONE with fabricated CRCA
17.3.2 powder coated junction box of size 120x170x100 with two no. of pad- No. 25 1,075 26,875
lock.
Supply & fixing of 50 pair tagblock with KRONE with fabricated CRCA
17.3.3 powder coated junction box of size 260x225x100 with two no. of pad- No. 16 2,350 37,600
lock.
Supply & fixing of 100 pair tagblock with KRONE with fabricated CRCA
17.3.4 powder coated junction box of size 450x250x100 with two no. of pad- No. 4 4,202 16,808
lock.
Supply & fixing of 200 pair tagblock with KRONE with fabricated CRCA
17.3.5 No. 1 11,677 11,677
powder coated junction box of suitable size
Supply & fixing of 1000 pair tagblock with KRONE with fabricated
17.3.6 No. 1 61,648 61,648
CRCA powder coated junction box of suitable size
17.4 Telephone / DATA Point Wiring

Supply and laying of specified make Cat 6 Computer data wire to be


17.4.1 done in prelaid PVC pipe / raceway , but without the cost of raceway or Rmtr 29,320 27 791,640
pipe ( the wire is to be drawn from server/switch to outlet point)

Supply and laying of specified make 0.5mm dia Annealed copper


cond. 5 pair telephone wire of specified make to be done in prelaid
17.4.2 PVC pipe of 25 mm dia / raceway of specified make, but without the Rmtr 24,780 28 693,840
cost of raceway or pipe ( the wire is to be drawn from Krone connector
of respective area to outlet point)

17.5 Telephone / Data Outlet Point


Supplying, installing, testing and commissioning of one telephone point
17.5.1 to be done with telephone outlet socket RJ-11 (jack type) and box of No. 793 148 117,364
the specified make.

Supply and Installation of Single I/O plate with 1 no of RJ 45 Cat 6 I/O


17.5.2 socket on same plate and with powder coated MS base box suitable No. 821 183 150,243
for Computer Data outlet.
Sub Total 17.0..... 5,665,099
18 Miscellaneous
18.1 PVC PIPES
Supplying and laying following sizes PVC pipe of approved make in
open / recess manner including execavation and back filling (if
required) as per layout and drawing and re-filling the trenches etc.
complete as directed.
Heavy gauge pipe in Open / Concealed manner minimum 25 mm dia
18.1.1 Rmtr 1,080 43 46,440
with GI pulling wire.
Heavy gauge pipe in Open / Concealed manner minimum 32 mm dia
18.1.2 Rmtr 420 60 25,200
with GI pulling wire.
Heavy gauge pipe in Open / Concealed manner minimum 40 mm dia
18.1.2 Rmtr 290 74 21,460
with GI pulling wire.

18.1.3 Heavy gauge pipe in Open / Concealed manner minimum 50 mm dia. Rmtr 200 101 20,200

18.1.4 Heavy gauge pipe in Open / Concealed manner minimum 75 mm dia. Rmtr 365 150 54,750

Heavy gauge pipe in Open / Concealed manner minimum 100 mm


18.1.5 Rmtr 135 173 23,355
dia.
Heavy gauge pipe in Open / Concealed manner minimum 150 mm
18.1.6 Rmtr 58 386 22,388
dia.
Sub Total 18.0..... 213,793
19 External Lighting
19.1 Poles
Supply & installation of 9.0 Mtr long GI street light pole with medium
class GI pipe duly pianted with two primer and coats of aluminium
19.1.1 No. 123 21,919 2,696,037
paint complete with base plate and single/double arm as per
requirment complete in all respect with followings.

1) Water tight Junction box equivalent to hensel make K9250 with 8


way connector and 2A MCB (separate for each light fixtures).

2) 40 mm diameter GI pipe for each cable entry .


3) Wiring up to the light fixture from the junction box using 3nos x 1.5
sq.mm. flexible copper wires of specified make.
4) Foundation Concrete coping with base plate.

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 36 of 55
Sr. No. Item Description Unit Quantity Rate Amount
5) Sprial/Coil Type Earthing and painting.
6) Excavation for erection of poles.

Supply & installation of 3.5 Mtr long GI street light pole with medium
19.1.2 class GI pipe duly pianted with two primer and coats of aluminium No. 505 7,734 3,905,670
paint complete with base plate complete in all respect with following

1) Water tight Junction box equivalent to hensel make K9250 with 8


way connector and 2A MCB (separate for each light fixtures).

2) 40 mm diameter GI pipe for each cable entry .


3) Wiring up to the light fixture from the junction box using 3nos x 1.5
sq.mm. flexible copper wires of specified make.
4) Foundation Concrete coping with base plate.
5) Sprial/Coil Type Earthing and painting.
6) Excavation for erection of poles.
19.2 Street light fixture
Supplying, erecting, connecting, testing and commissioning of
following type Street Light Fixture with all necessary Hadware, Internal
Wiring with Lamp,Ballast etc. all required accessories Complete in all
respect.
19.2.1 Light Fixture Type C with basic rate as specified separately No. 150 12,222 1,833,300
19.2.2 Light Fixture Type D with basic rate as specified separately No. 400 42,059 16,823,600
19.2.3 Light Fixture Type E with basic rate as specified separately No. 101 59,942 6,054,142
19.3 Street light panel
19.3.1 External Lighting Panel - 1 No. 1 51,246 51,246
As per attached Single Line Diagram
19.3.2 External Lighting Panel - 2 No. 1 33,521 33,521
As per attached Single Line Diagram
19.4 Section feeder Pillar ( Outdoor Type) No. 4 88,057 352,228

Supplying, unloading at site, shifting to site, assembling, leveling,


grouting, erecting, Testing, & Commissioning double
compartmentalized Double door type section feeder piller with IP 55
protection & should be powder coated fabricated from 10 Guage
CRCA sheet & folded channel totally enclosed cubical type with pad
lock arrangment. The successful tenderer will have to prepare general
arrangement with dimensions & get it approve through Architect/
Consultant. All civil work including RCC platform for section pillar
should be in scope of Electrical contractor complete in all respect as
per detail drawing and directed by engineer incharge.

As per attached Single Line Diagram


Sub Total 19.0..... 31,749,744
20 Television Distribution

Supply, installation, connection, testing and commissioning of


television system with supplying of television cables as per
specification and drawings. The unit rate considered on running meter
basis includes supply, laying, connection, testing and commissioning
of television cables through rigid PVC conduit from junction of Data
Room. The cable shall be installed in a concealed manner in the
vertical riser including supply & fixing splitter / Junction box of specified
make.

20.1 PVC Conduits


Supply & laying of 25 mm dia. Open/conceal manner heavy guage
20.1.1 Rmtr 3,770 43 162,110
rigid PVC pipe.
Supply & laying of 40 mm dia. Open/conceal manner heavy guage
20.1.2 Rmtr 90
rigid PVC pipe.
20.2 Cabling
20.2.1 Supplying and Laying of RG 6 TV cable in prelaid conduit Rmtr 3,600 38 136,800
20.2.2 Supplying and Laying of RG 11 TV cable in prelaid conduit Rmtr 4,130 44 181,720
20.3 Junction box / Splitter
20.3.1 Supply & fixing of 3/4 way splitter No. 107 713 76,291
20.3.2 Supply & fixing of 6 way splitter No. 12 1,003 12,036
20.3.3 Supply & fixing of 8 way splitter No. 6 2,327 13,962
20.3.4 Supply & fixing of 16 way splitter No. 6 3,922 23,532
20.4 Television Outlet Point

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 37 of 55
Sr. No. Item Description Unit Quantity Rate Amount
Supplying, installing, testing and commissioning of one television point
20.4.1 to be done with television outlet socket and box of the APPROVED No. 152 208 31,616
make.
Sub Total 20.0..... 638,067

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09
Page 38 of 55
Tender Documents
Aga Khan Academy, Hyderabad

SUMMARY OF IBMS WORKS

Sr. No. Description Total Amount (Indian Rupees)

1 Section 01 - Fire Alarm System 16,676,595

2 Section 02 - Public Address System 14,959,473

3 Section 03 - CCTV System 7,830,375

4 Section 04 - Access Control System 5,315,934

5 Section 05 - Gas Based Fire Suppression System 1,381,738

6 Section 06 - Water Leak Detection System 2,054,829

7 Section 07 - Extinguishers 541,795

8 Section 08 - Networking 6,421,813

9 Section 09 - Building Management System 8,034,172

Total Amount: 63,216,724

Amount in Words:

Signature of Authorised Signatory Stamp of the Bidder

Please read this Abstract in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page 39 of
02.12.09 55
BILL OF QUANTITIES - IBMS WORKS
Sr. No. Item Description Unit Quantity Rate Amount
SECTION 1 - Fire Alarm System

Supply & Installation Testing ,commissioning of , Analouge


1.0 Addressable Main Fire Alarm with Power supply & battery backup
complete as per following features:

Adequate Loop Capacity to accommodate following Detectors&


Devices .
Large LCD display minimum 80 Character
Fully networkable, true peer to peer,with builtin Network Card
Shall integrate Control,Monitor,Relay modules,Duct Detectors,Beam
Detectors,Flame detectors.
System network shall be Web Enabled for Monitoring thru
Intranet/Internet
Battery of 48 hrs backup in normal condition,+ 1 hr backup with 25%
Loop under fire condition.
1.0.1 150 Detectors + 50 Devices Set 7 259,969 1,819,783
1.0.2 300 Detectors + 100 Devices Set 5 Inc
1.0.3 450 Detectors + 100 Devices Set 1 Inc
1.0.4 600 Detectors + 100 Devices Set 500,771

Addressable type OPTICAL smoke detector with sensitivity range of


1.1 Nos. 1,773 3,244 5,751,612
0.5% to 2.35% per foot with base & MS Powder coated Junction Box

Addressable type MUILTISENSOR smoke detector with heat sensing


1.2 intelligent type capable to set desired alogrithms,with base & MS Nos. 4,213
Powder coated Junction Box
Addressable type Heat detector of rate of rise temperature detection of
15 degree F to 20 degree F per minute or Fixed temerature with base
1.3 Nos. 164 2,605 427,220
& MS Powder coated Junction Box.

Remote response indicator having twin LED flush mounted on false


1.4 Nos. 90 125 11,250
ceiling/wall
Addressable Manual Pull station with Reset Lock & Key arrangment
1.5 Nos. 230 5,746 1,321,580
with back box.
1.6 Coventional Sounders 85 DB minimum at 10 feet . Nos. 262 1,800 471,600
1.7 Coventional Hooter with Strobe flasher 110 Cd Nos. 35 3,029 106,015
1.8 Monitor Modules in suitable ABS Plastic glossy Box. Nos. 100 2,562 256,200
1.9 Control/Relay Modules in suitable ABS Plastic glossy Box. Nos. 200 3,810 762,000
1.1 Fault Isolator Module,in suitable ABS Plastic glossy Box. Nos. 200 2,707 541,400
Online UPS suitable for PA & Fire Panels with 30 mts backup ,with
1.11 Nos.
battery Charger & Battery Backup.
1.11.1 800 VA Nos. 5 28,728 143,640
1.11.2 1200 VA Nos. 5 28,728 143,640
1.11.3 1800 VA Nos. 1 63,059 63,059
1.11.4 2000 VA Nos. 63,059

Network Annunciation Panel with minimum 640 character display for


monitoring & controlling other Panels on the network loop with Power
1.12 Nos. 1 104,474 104,474
supply. Peer To Peer Networked with all main panels, such that the
status of the entire system shall be available on individual Annunciator.

SLC Cables : Stranded Copper conductor,PVC insulated


1.13
Twisted,FRLSPVC Sheathed 650 V as per IS 694.
1.13.1 1P x 1.5 mm2 Mtrs 23,270 36 837,720
1.13.2 1Px 2.5 mm2 Mtrs 5,000 50 250,000

Network Cable : 2P x 1.5 mm2, Stranded Copper conductor,PVC


1.14 insulated,individual + overall Sheilded,Armoured FRLS sheathed Mtrs 10,000 109 1,090,000
Cable 650 V as per IS 1554

ABS Plastic Junction Box with DIN rail & elmex 1.5 Sq.mm Terminals
1.15
with Lock & Key arrangement approved for outdoor use IP 66

1.15.1 4 way with 8 Terminals Nos. 26 679 17,654


1.15.2 8 way with 12 Terminals Nos. 13 1,077 14,001

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
40 of 55
Sr. No. Item Description Unit Quantity Rate Amount
FRPVC Medium Conduit to be laid concealed in ceiling/walls &
1.16 Flexible Conduits wherever required complete with Cable
glands,ferruls & end terminations
1.16.1 25mm Mtrs 23,270 52 1,210,040
1.16.2 32mm Mtrs 5,000 65 325,000

Touch Screen display Panel with dymanic Graphics with complete


1.17 monitoring of the System components on Monitor with required Set 1 970,956 970,956
configuration 17" Monitor with Interface for RS 485/TCP/IP complete

1.18 BACnet Integration Card with necessary Hardware & software Set 123,302
Beam Detector set (transmitter + Receiver) 70 Mtr x 15 Mtr with Power
1.19 Set 1 37,751 37,751
supply complete with test Switch & key.
Sub Total 1.0 16,676,595

SECTION 2 - PUBLIC ADDRESS SYSTEM

2.0 Speakers
METAL GRILL speakers with line matching transformer for direct
connecting to 100/70 V output line.
2.0.1 6 Watts Output suitable for flush mounting Nos. 191 1,890 360,990
2.0.2 6 Watt Output wall mount with metal Box Nos. 783 2,521 1,973,943
20W ABS Weatherproof Horn speakers with 100V line matching
2.0.3 Nos. 50 3,530 176,500
transformer, IP66.
2.0.4 10W Wallmount Music cabinet speaker Nos. 224 2,963 663,712
2.1 Microphones

96 Zone Touchscreen Call Station with goose neck Microphone with


zone selection & all call selection to be connected with the network
2.1.1 Nos. 1 158,362 158,362
controller with music routing facility, automatic pre-recorded message
broadcast, Complying to EN60849 & BS 5839 part 8

Remote paging 8 Zone RS 485 based digital microphone complying to


2.1.2 Nos. 2 32,722 65,444
BS 5839
2.1.3 Wireless Microphone for Playgrounds 2 15,840 31,680
2.2 Network Controllers
2.2.1 Network controller - 4 zone with following features Set 15 205,108 3,076,620
Microcontroller based with built in DSP, 4x4 matrix, switching, pre-
recorded message store, expandable to 256 zones,
Accomodates 5 set of Amplifiers/ zones

Accomadates 96 Zone Call stations & can be cascaded upto 32 nodes

Automated Evacuation message facility


Networkable to 99 such Controllers.
EN60849 & BS5839 part 8 compliant
Audio monitoring switchover system controller with single audio
2.2.2 channel, allows to connect upto 16 zones, EN60849 & BS5839 part 8 Nos. 1 261,920 261,920
compliant

Zone switcher for individual zone selection througn the automatic


2.2.3 switching of the relevant 100V speaker line to the corresponding 100V Nos. 2 90,804 181,608
amplifier output, EN60849 & BS5839 part 8 compliant

D class Digital Amplifiers with 230 VAC networkable with all


2.3
interconnecting Cables with following outputs :
2.3.1 240W single channel Set 24 54,753 1,314,072
2.3.2 480W single channel Set 10 67,680 676,800
2.3.3 120W single channel Set 3 53,997 161,991
2.4 TCP/IP Audio distribution system comprising of :-

2.4.1 TCP/IP software server with GUI EN60849 & BS5839 part 8 compliant Set 1 117,661 117,661

TCP/IP remote station software license, including 1 Out TCP/IP audio


2.4.2 Set 1 49,088 49,088
exstreamer EN60849 & BS5839 part 8 compliant
Control station software license, including 1 In TCP/IP audio in-
2.4.3 Set 10 114,477 1,144,770
streamer EN60849 & BS5839 part 8 compliant
Music Source with AM/FM/ CD Changer with optic firbre output
2.5 Set 1 20,358 20,358
complete with interconnecting Cables.

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
41 of 55
Sr. No. Item Description Unit Quantity Rate Amount
Stranded Copper conductor,PVC insulated ,FRLSPVC Sheathed 650
2.6
V as per IS 694.
2.6.1 2C x 1.5 mm2 Mtrs 14,630 36 526,680
2.6.2 2Cx 2.5 mm2 Mtrs 2,500 50 125,000

Central Monitoring Work Station Client with Core 2 Duo Intel


processor with minimum 160Gb HDD, 1 GB RAM, 19" TFT Monitor,
2.7 DVD Writer, two serial and one parallel ports, multimedia speakers, Set 1 95,039 95,039
infrared mouse; Work station shall be preloaded with requisite MS
Windows Licensed software compatible with the BMS platform

ABS Plastic Junction Box with DIN rail & elmex 1.5 Sq.mm Terminals
2.8
with Lock & Key arrangement approved for outdoor use IP 66

2.8.1 4 way with 8 Terminals Nos. 90 679 61,110


2.8.2 8 way with 12 Terminals Nos. 45 1,077 48,465

FRPVC Medium Conduit to be laid concealed in ceiling/walls &


2.9 Flexible Conduits wherever required complete with Cable
glands,ferruls & end terminations
2.9.1 25mm Mtrs 16,190 52 841,880
2.9.2 32mm Mtrs 2,500 65 162,500
2.30 Volume Control suitable for 10 Watts Operation with Back box Nos. 39 2,130 83,070
PA Rack suitable for 1 Network Controller,Amplifiers,Switchers &
related accessories located per building/Cluster of Buildings with
2.31 Set 15 41,337 620,055
ventilation & openable glass door in front complete with
interconnecting Cables

Mounting Poles for outdoor Horn Speakers,fabricated of GI ERW


Medium Pipes of 80mmx2 mtr/65x2mtr/50x2mtrdiameter with total
2.32 height of 6 Mtrs with flanged conection at the bottom with RRC Set 45 43,559 1,960,155
foundation of 330x300x800 mm deep includng excavation & backfilling
complete.

Sub total 2.0 14,959,473


SECTION 3 - CCTV System
Network video management software license to support up to 70
cameras, 40 camera licenses, 5 user licenses, Failover directory,
3.0 Lot 1 993,228 993,228
Failover recording, Virtual Matrix capablity, Audio capablity, Maps and
alarm management.

Hi-Resolution Mpeg4 video with Ethernet (CAT5) TCP/IP


3.1 Communication Port and Power over Ethernet option, Two way audio, Nos. 35 35,596 1,245,860
with varifocal lens 2.9mm - 10mm as per specifications.

Vandalproof Outdoor pole Mount Pan, Tilt and Zoom (PTZ), Hi-
Resolution Mpeg4 video Day/Night and 23x optical 12x digital zoom
3.2 Nos. 12 219,997 2,639,964
with Ethernet (CAT5) TCP/IP communication port as per
specifications.

Network video recorder server/servers with 2TB usable RAID5 storage


3.3 storage as per specifications, and database/failover database server Lot 1 516,582 516,582
as required

Failover server/servers with 2TB usable RAID5 storage as per


3.4 Lot 1 515,795 515,795
specifications, and database/failover database server as required

Client workstations as per specifications to accommodate one 19"


monitors & two 32" Monitors in main control room, One 19" monitor &
3.5 one 32" monitor each in 2 local control rooms with different content Lot 1 633,217 633,217
possiblity on each monitor i.e Multiplexed video, alarm video, maps,
spot monitor function etc.
3.6 19" colour TFT monitor for above client workstation Nos. 4 36,952 147,808
3.7 32" colour TFT monitor for above client workstation Nos. 5 60,191 300,955
3.8 CAT 6 Patch Chords within the BMS Room Lot 1 20,587 20,587
3.9 Equipment rack / Console as per requirement Lot 1 103,747 103,747
CAT 6 Cables with end Connections from Camera to LAN Switch to be
3.10 Mtrs 2,500 40 100,000
laid in below PVC Conduits

ABS Plastic Junction Box with RJ 45 Jack connection 2 way with Lock
3.11 Nos.
& Key arrangement approved for outdoor use IP 66
3.11.1 2 way with 2 Terminals Nos. 20 570 11,400

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
42 of 55
Sr. No. Item Description Unit Quantity Rate Amount

FRPVC Medium Conduit with fittings concealed in ceiling/wall or GI


3.12 Saddle Spacers at every 0,3 Mtrs & Flexible Conduits wherever
required complete with Cable glands,ferruls & end terminations

3.12.1 25mm Mtrs 2,500 52 130,000


3.12.2 32mm Mtrs 65

Redundant Power Supply suitable for outdoor PTZ Camera`s with


Input 230VAC +/- 10%,Output 12V +/- 2Volt,load regulation & line
3.13 Nos. 12 1,976 23,712
regulation less than 0.1%,Electronic protection against overload &
short circuit,outout ripple less than 1 milli volt RMS,.

Mounting Poles for outdoor Camera`s,fabricated of GI ERW Medium


Pipes of /100mmx2 mtr/80mmx2 mtr/65mm x2mtr/50mmx2mtr
3.14 diameter with total height of 8 Mtrs with flanged conection at the Nos. 10 44,752 447,520
bottom with RRC foundation of 330x300x1000 mm deep includng
excavation & backfilling complete.

Sub total 3.0………. 7,830,375


SECTION 4 - ACCESS CONTROL SYSTEM
Network Intelligent 32 BIT Native Onboard IP Access Control & Alarm
4.0 Management Panels for Smart Card or a group of Panels capable of
controlling all the Card Readers as spec`s below:
Intelligent embedded network device for access control and alarm
monitorin.
Firmware stored in flash memory that is easy to update on LAN
Network.
Multiple card reading technologies supported, Proximity, Smart card,
Biometric
Variable card formats supported.
Multiple facility codes supported
Remote database administration
Remote alarm monitoring
Inbuilt database backup to facilitate offline use

Supports supervised inputs (door contacts, motion detectors, glass


break sensors, and so on) and outputs (programmable auxiliary relay)

RS-422 (4 wire) and RS-232 ) connectivity supported


Local, Global, Soft, Hard Anti-pass back supported
Automatic locking & unlocking of the doors
Battery Charger & Battery Backup for 4 hrs
4.0.1 2 Reader Controller Nos. 5 37,555 187,775
4.0.2 4 Reader Controller Nos. 19 46,798 889,162
4.1 Smart( i Class) Card Reader Nos. 70 4,394 307,580
4.2 Egress Switch Nos. 867
Electromagneitc Lock with builtin Magnetic contacts Doors. 600 lbs
4.3 Nos. 53 5,472 290,016
capacity
4.3.1 Drop Bolt Nos. 2 3,151 6,302
Emergency Release Switch in Green Polycarbonate housing,push to
4.4 Nos. 50 819 40,950
breakglass type.
4.5 Magnetic Contacts Nos. 20 154 3,080

4.6 16 K(2KB) Contactless Smart Card with 2 Applications(iCLASS) Nos. 500 442 221,000

Server Access Control Software:Licenced Enterprise version Server


Software , to be loaded at the central Server,with real time
4.7 Nos. 1 91,998 91,998
communicator software ,specification of the Server to be specifed to
the client to provide the same.

Client Access Control System Software, with real time


4.8 communicator software, Configuration of required PC to be specified to Nos. 1 23,958 23,958
Client to provide the same.

Central Work Station Server with Core 2 Duo Intel processor with
minimum 240 GB HDD, 2 GB RAM, 19" TFT Monitor, DVD Writer, two
4.9 serial and one parallel ports, multimedia speakers, infrared mouse; Set 1 554,396 554,396
Work station shall be preloaded with requisite MS Windows Licensed
software compatible with the BMS platform

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
43 of 55
Sr. No. Item Description Unit Quantity Rate Amount

Central Monitoring Work Station Client with Core 2 Duo Intel


processor with minimum 160Gb HDD, 1 GB RAM, 19" TFT Monitor,
4.10 DVD Writer, two serial and one parallel ports, multimedia speakers, Set 1 95,039 95,039
infrared mouse; Work station shall be preloaded with requisite MS
Windows Licensed software compatible with the BMS platform

Stranded Copper conductor,PVC insulated ,FRLSPVC Sheathed 650


4.11
V as per IS 694.
4.11.1 8 c x 0.75 Sq.mm Mtrs 5,150 59 303,850
4.11.2 4c x 0.75 Sq.mm Mtrs 5,150 36 185,400
4.11.3 2c x 0.75 Sq.mm Mtrs 10,490 27 283,230

ABS Plastic Junction Box with DIN rail & elmex 0.75 Sq.mm Terminals
4.12
with Lock & Key arrangement approved for outdoor use IP 66

4.12.1 4 way with 8 Terminals Nos. 20 679 13,580


4.12.2 8 way with 12 Terminals Nos. 10 1,077 10,770
FRPVC Medium Conduit to be laid concealed in ceiling/walls &
4.13 Flexible Conduits wherever required complete with Cable
glands,ferruls & end terminations
4.13.1 25mm Mtrs 15,150 52 787,800
4.13.2 32mm Mtrs 65
Boom Barrier Fixed- 2.5 mtr long ,made of 2mm zinc coated sheet
steel Powder coated & base of SS with reflective tape strips,with
4.14 opening time less than 2 sec`s,complete with fixed support post IP 55 Set 8 127,506 1,020,048
Protection with manual maneovering.It shall also include operation with
remote & a manul switch override.
Sub total 4.0……………… 5,315,934
SECTION 5 - GAS BASED FIRE SUPPRESSION SYSTEM

NOVEC 1230 storage Tank & Valve assembly capacity suitable for
5.0 storage of following aqty of agent, Empty CCOE Approved with low 1 263,913 263,913
pressure switch provision & safety brust disc
5.1 Novec 1230 Fire Protection Fluid, OEM Factory Fill in Kgs Nos. 75 4,492 336,900
5.2 Tank Bracket Assembly Nos. 1 7,263 7,263
5.3 Single-Tank Swivel Adaptor, 2 in with Discharge Hose Nos. 1 32,532 32,532
5.4 Electric Actuator Assembly Nos. 1 34,100 34,100
5.5 Local Manual Actuator Nos. 1 11,311 11,311
5.6 Nozzle, Brass, Drilled ( 1.25 in) - 360 degree Nos. 4 9,827 39,308
5.7 Nozzle, Brass, Drilled ( 1.5 in) - 360 degree Nos. 2 10,444 20,888
Auto/Manual selector Switch with key lock arrangement in Glossy ABS
5.8 Nos. 1 5,811 5,811
Enclosure
LED type display sign board flashing with inbuilt Sounder "EVACUATE
5.9 Set 1 1,630 1,630
GAS RELEASED" & "DONOT ENTER"

Sch 40 Seamless ASTM 106 gr B, piping with 3000psi fittings ,rigid


5.10 Lot 1 163,203 163,203
supports with angles,2 coats of Zinc primer & 3 coats of P.O red Paint.

5.11 Cylinder Low Pressure Switch Nos. 1 4,498 4,498


Single Cross Zone ( 2 zone) Detection & Release Panel with following
5.12 Nos. 1 210,301 210,301
features:
Cross Zoning with timer card ( 0-256 secs)
Input for low pressure switch connection
Abort/Release inputs
Manual & Standby Modes
Solenoid output of 2.0 Amps
Builtin Power supply
Battery backup of 24 AH

5.13 Conventional Optical Smoke Detectors with Bases Nos. 6 1,028 6,168
5.14 Release cum Abort Switch with key & lock Nos. 1 11,477 11,477
Stranded Copper conductor,PVC insulated ,FRLSPVC Sheathed 650
5.15
V as per IS 694.
5.15.1 2C x 1.5 mm2 Mtrs 2,500 40 100,000
5.15.2 2Cx 2.5 mm2 Mtrs 55

ABS Plastic Junction Box with DIN rail & elmex 1.5 Sq.mm Terminals
5.16
with Lock & Key arrangement approved for outdoor use IP 66

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
44 of 55
Sr. No. Item Description Unit Quantity Rate Amount
5.16.1 4 way with 8 Terminals Mtrs 2 679 1,358
5.16.2 8 way with 12 Terminals Mtrs 1 1,077 1,077
FRPVC Medium Conduit with fittings & GI Saddle Spacers at every 0,3
5.17 Mtrs & Flexible Conduits wherever required complete with Cable
glands,ferruls & end terminations
5.17.1 25mm Mtrs 2,500 52 130,000
5.17.2 32mm Mtrs 65
Sub total 5.0…………… 1,381,738
SECTION 6 - WATER LEAK DETECTION SYSTEM
6 Water Leak Sensor Cable - 5 Mtrs long with end connections Lenghts 100 5,065 506,500
6.1 Piezo Sounder -White 65db Nos. 1 3,029 3,029

Water Leak Module with 230 VAC input & output inform of relay on
6.2 Nos. 100 11,543 1,154,300
water leak cable activation,housed is ABS Plastic Ju, Box - IP 66

Stranded Copper conductor,PVC insulated ,PVC Sheathed 650 V as


6.3
per IS 694.
6.3.1 2C x 0.5 mm2 Mtrs 4,000 25 100,000
6.3.2 4Cx 0.5 mm2 Mtrs 1,000 31 31,000

FRPVC Medium Conduit with fittings & GI Saddle Spacers at every 0,3
6.4 Mtrs & Flexible Conduits wherever required complete with Cable
glands,ferruls & end terminations
6.4.1 25mm Mtrs 5,000 52 260,000
6.4.2 32mm Mtrs 65
Sub total 6.0……….. 2,054,829
SECTION 7 - EXTINGUISHERS
4.5 KG CO2 fire Extingusher with horn & sqeez grip handle,CCOE
7.0 Nos. 11 5,669 62,359
approved cylinder with wall mounting bracket .

5 Kg- ABC Type stored pressure fire Extingusher with safety brust
7.1 Nos. 15 3,688 55,320
disc & NRV for pressure gauge on wall with mounting bracket .

9 ltr Water Type cartridge operated with safety brust disc & NRV for
7.2 Nos. 198 2,142 424,116
pressure gauge on wall with mounting bracket .
Sub total 7.0…………… 541,795
SECTION 8 - NETWORKING

Core Switch - 28 Ports 2X


10/100/1000 Ethernet Ports, 2 X Gigabit SFP Ports & 100 X 100 FX
Fiber SFP Ports, Layer 3, VLAN, Fully Managed, Stackable (upto 8
8.0 Nos. 1 227,424 227,424
Units), Supports Clustering, 12.8 Gbps Switching Capacity, RADA,
Auto Voice LAN, Auto VLAN, Secured Managed, Layer & 2 Support

Giga Switch - 12 Ports 8 x 10/100/1000


Ports , 4 x Giga SFP Combo Ports, 4 X 100 MB SFP Slots, 1 X 10 GB
8.1 SFP Slot, Support for Clustering, 44 Gbps Switching Capacity, RADA, Nos. 2 99,090 198,180
Auto Voice LAN, Auto VLAN, Secured Managed, Layer & 2 Support

100 FX - 100 MBPS Fiber SFP Module 100BASE-LX SFP Transceiver


8.2 Nos. 36 13,167 474,012
- Single Mode LC Type
Giga Fiber SFP Module 1000BASE-LX SFP Transceiver - Single Mode
8.3 Nos. 4 33,632 134,528
LC Type
26 Ports Layer 2 Network Switch with 24 X 10/100 Ports with POE , 2
8.4 X 10/100/1000 Giga Combo SFP Ports, 2 X 100MB SFP Slots, RADA , Nos. 20 66,663 1,333,260
Auto VLAN, Secured Managed
8.5 10/100 Ethernet Media Convertor - Single Mode SC Type Nos. 18 6,178 111,204

8.6 Outdoor Junction Boxes for Media convertors, Fiber LIU & Termination Nos. 18 1,983 35,694

8.7 6 Core Outdoor Steel Armoured Single Mode Optical Fiber Cable Mtrs 20,000 95 1,900,000
8.8 Fiber Pigtails - Single Mode (3 Meters) SC Type Nos. 456 947 431,832

8.9 Fiber Patch Cords - Single Mode Duplex (3 Meters) SC-LC Type Nos. 76 2,088 158,688

8.10 Rack Mount LIU - 12 Ports with SC-SC Type Adapters Nos. 20 9,364 187,280
8.11 Rack Mount LIU - 24 Ports with SC-SC Type Adapters Nos. 1 15,759 15,759
8.12 24 Ports CAT 6 PatchMax Panel Nos. 21 9,017 189,357
8.13 CAT 6 Patch Cords- 2 Meters Nos. 480 289 138,720
8.14 CAT 6 I/O Nos. 4 326 1,304
8.15 CAT 6 Cable to be laid in Medium Conduits Nos. 5,000 37 185,000

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
45 of 55
Sr. No. Item Description Unit Quantity Rate Amount
8.16 9 U - Wall Mount Network Nos. 20 6,736 134,720
8.17 42 U - 800 X 1000 Network/ Server Rack Nos. 1 53,851 53,851
8.18 RJ 45 Jack Holder with face plate & back Box Nos. 500 512 256,000
FRPVC Medium Conduit to be laid concealed in ceiling/walls &
8.19 Flexible Conduits wherever required complete with Cable
glands,ferruls & end terminations
8.19.1 25mm Mtrs 5,000 51 255,000
8.19.2 32mm Mtrs 57
Sub total 8.0…………… 6,421,813
SECTION 9 - Building Management System
9.0 IBMS Server and work station Hardwares

Central Work Station Server with Core 2 Duo Intel processor with
minimum 240 GB HDD, 2 GB RAM, 19" TFT Monitor, DVD Writer, two
9.0.1 serial and one parallel ports, multimedia speakers, infrared mouse; Set 1 87,119 87,119
Work station shall be preloaded with requisite MS Windows Licensed
software compatible with the BMS platform

Central Monitoring Work Station Client with Core 2 Duo Intel


processor with minimum 160Gb HDD, 1 GB RAM, 19" TFT Monitor,
9.0.2 DVD Writer, two serial and one parallel ports, multimedia speakers, Set 2 55,440 110,880
infrared mouse; Work station shall be preloaded with requisite MS
Windows Licensed software compatible with the BMS platform

9.0.3 600 dpi or better A3 size Ink Jet colour printer 1 28,512 28,512

9.1 Customization of IBMS "Development and Runtime" Softwares

Development Version (server version with full function edit facility)


unlimited tags BMS software supporting LON/BACNET protocol as User
9.1.1 1 651,209 651,209
specified with all monitoring/control modules including but not limited to License
full function Report / Trending / Alarms / MIMIC / LAN / WAN modules

9.1.2 Run time version BMS software for with license (edit feature) License 2 Inc

Additional Web browser module with unlimited user capability,to be


9.1.3 License 1 Inc
installed at Router level
Additional email alarm notification module with unlimited user
9.1.4 License 1 76,626 76,626
capability
9.1.5 Software customization to suit system requirement Lot 1 Inc
System Data Integrators to acquire soft data over IP for following
9.1.6
Devices
9.1.6.1 VRV System (BACNET over IP) Set 5 Inc
9.1.6.2 UPS System MP Panel Set 4 Inc
9.1.6.3 DG Set MP Panel Set 1 778,642 778,642
9.1.6.4 Substation Load Managers (MODBUS RTU over IP) Set 4 Inc

9.1.6.5 Field (Residence Blocks) Load Managers (MODBUS RTU over IP) Set 15 Inc

9.1.6.6 AutoChange Over Panel (MODBUS over IP) Set 1 Inc


9.1.6.7 Water Softening Plant Panel Set 1 Inc
9.2 IP based DDC Controller and hardware

IP based Direct Digital controllers supporting either - BACNet or


LonWork - over IP communication platform designed for the required
IO paramteres (as per Annexure 1), housed in IP 55 MS powder
coated panel duly internally - wired and tested - at OEM works; the
9.2.1 Set
DDCs offered shall be with LCD display of suitable characters and
membrane function keys for local programming and control;
alternatively, blind DDCs with mobile OP panel shall have dedicated
OP to one DDC each; DDCs shall be supplied for following

9.2.1.1 DDC 1 for ACAD Building Environmental System Set 1 44,533 44,533
9.2.1.2 DDC 2 for Sr ACAD Building Environmental System Set 1 21,019 21,019
9.2.1.3 DDC 3 for Jr ACAD Building Environmental System Set 1 21,019 21,019
9.2.1.4 DDC 4 for Sr ACAD Art Block Environmental System Set 1 21,019 21,019
9.2.1.5 DDC 5 for ACAD Building UPS System Set 1 21,019 21,019
9.2.1.6 DDC 6 for Jr ACAD UPS System Set 1 21,019 21,019
9.2.1.7 DDC 7 for Sr ACAD UPS System Set 1 21,019 21,019
9.2.1.8 DDC 8 for Nursery UPS System Set 1 21,019 21,019

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
46 of 55
Sr. No. Item Description Unit Quantity Rate Amount
9.2.1.9 DDC 9 for DG Set Set 1 33,499 33,499
9.2.1.10 DDC 10 for Electrical System Set 1 28,507 28,507
9.2.1.11 DDC 11 to DDC 24 - Fire and Leak Detection for 14 clusters Set 14 21,019 294,266
9.2.1.12 DDC 25 - Fire and Leak Detection for Resi Cluster Set 1 189,165 189,165
9.2.1.13 DDC 26 for Water Management Set 1 94,059 94,059
9.2.1.14 DDC 27 for ACAD FFG System Set 1 21,019 21,019
9.2.1.15 DDC 28 for Sr ACAD FFG System Set 1 21,019 21,019
9.2.1.16 DDC 29 for Jr ACAD FFG System Set 1 21,019 21,019
9.2.1.17 DDC 30 for Athletic Block FFG System Set 1 21,019 21,019
9.2.1.18 DDC 31 for Acad Server Room Fire Suppression System Unit 1 21,019 21,019
9.2.1.19 Xenta OP panels for each DDC above Unit 31 14,539 450,709
Expansion Modules compatible for processors offered under above
9.2.1 Unit
DDCs
9.2.1.1 With 4 UI & 2UO ( Universal Input/Outputs) Unit 31,310
9.2.1.2 With 8 UI & 4 UO ( Universal Input/Outputs) Unit 31,310
9.3 Pre Calibrated Field Devices
Scope shall cover installation with all necessary fixtures and protection
as per manufacturer's standards
9.3.1 For Environmental System
Duct mounted Resistance Temperature Detectors for TFA Leaving
9.3.1.1 Nos. 6 907 5,442
Temp
Wall Mounted Combined T+Rh Transmitter for Server Room and UPS
9.3.1.2 Nos. 5 8,390 41,950
Rooms
9.3.1.3 Wall Mounted Ambient T+Rh transmitter for outdoor duty Nos. 1 8,390 8,390
9.3.2 DG Room Instruments

9.3.2.1 Ultra Sonic Level Transmitter for 5 M rating installed on Day Tank Nos. 2 105,537 211,074

9.3.2.2 SS Level switch for installation on tankage Nos. 16,040


Digital Energy Meters with back lit LCD real time display and
9.3.3 Nos. 20,937
MODBUS over IP Serial communication
9.3.4 Water Management Instruments

9.3.4.1 Absolute Pressure Transmitters - Borewell/Pumps Discharge Press Nos. 16 5,330 85,280

9.3.4.2 Ultra Sonic Level Transmitter for 5 M rating for UGR and ESR Nos. 2 105,537 211,074
9.3.4.3 water Differential Pressure switches Nos. 16 7,208 115,328
9.3.5 Fire Fighting System Instruments
9.3.5.1 Absolute Pressure Transmitters - Pumps Discharge Pressure Lot 8 5,330 42,640
9.3.5.2 Ultra Sonic Level Transmitters for 5 M rating for Fire Tank Level 5 105,537 527,685
9.3.5.3 water Differential Pressure switches Nos. 8 7,208 57,664
9.4 Calibration Work
Calibration of Field devices supplied under D : at site with
Lot 1 89,531 89,531
documentation
9.5 Cabling and Conduits
Stranded Copper conductor,PVC insulated ,FRLSPVC Sheathed 650
9.5.1
V as per IS 694.
9.5.1.1 8 c x 1.5 Sq.mm Mtrs 1,000 91 91,000
9.5.1.2 4c x 1.5 Sq.mm Mtrs 5,000 52 260,000
9.5.1.3 2c x 1.5 Sq.mm Mtrs 15,000 36 540,000

ABS Plastic Junction Box with DIN rail & elmex 1.5 Sq.mm Terminals
9.5.2
with Lock & Key arrangement approved for outdoor use IP 66

9.5.2.1 4 way with 8 Terminals Nos. 80 679 54,320


9.5.2.2 8 way with 12 Terminals Nos. 20 1,077 21,540

CAT 6 Cables with end Connections from Camera to LAN Switch to be


9.5.3 Mtrs 2,500 52 130,000
laid in below PVC Conduits
FRPVC Medium Conduit to be laid concealed in ceiling/walls &
9.5.4 Flexible Conduits wherever required complete with Cable
glands,ferruls & end terminations
9.5.4.1 25mm Mtrs 20,000 52 1,040,000
9.5.4.2 32mm Mtrs 65
9.5.4.3 Supply/laying of GI perforated cable tray
9.5.4.3.1 100 x 50 Rmt 500 196 98,000
9.5.4.3.2 200 x 50 Rmt 300 355 106,500
9.5.4.3.3 300 x 50 Rmt 200 525 105,000
9.6 Fire Stoppings

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
47 of 55
Sr. No. Item Description Unit Quantity Rate Amount
Expanding Firestop Foam with upto 7 times expansion,repenetrable,to
9.6.1 protectagainst fire,smoke,& water complete with dispenser,mixer,& SQ.ft 50 5,226 261,300
cleaner.
Firestop Mortar -Fire resistance cement based thermal insulating
9.6.2 Kg 500 1,621 810,500
Compound for Cable tray penetration
Sub total 9.0………….. 8,034,172

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
48 of 55
Tender Documents
Aga Khan Academy, Hyderabad

SUMMARY OF FIRE FIGHTING WORKS

Sr. No. Description Total Amount (Indian Rupees)

1 Section 01 - External Fire Fighting Works 2,199,083

2 Section 02 - Internal Fire Fighting Works 2,977,374

3 Section 03 - Automatic Sprinkler System 1,103,812

4 Fire Pumps and Accessories 435,405

Total Amount: 6,715,674

Amount in Words:

Signature of Authorised Signatory Stamp of the Bidder

Please read this Abstract in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09 Page 49 of 55
BILL OF QUANTITIES - FIRE FIGHTING WORKS
Sr. No. Item Description Unit Quantity Rate Amount
SECTION 1 - EXTERNAL FIRE FIGHTING WORKS
1 FIRE DOWNCOMMER SYSTEM

Providing and laying .G.I. pipes to IS:1239 (heavy class-C) in trenchs


1.1 including all fittings like anchor fasteners, coupling bends elbows, tees
etc weld on screwed joints as required (external : Below Ground)

a) 100 mm dia Rmt 619 1,321 817,699


b) 80 mm dia Rmt 992

Providing pipe protection for underground pipes from corrosion,


1.2 paining pipe with PYPKOTE primer and covered with PYPKOTE
antiicorrosive tape (4mm thick) as per boq.
a) 100 mm dia Rmt 619 180 111,420
b) 80 mm dia Rmt 145

Providing and fixing short body double flanged cast iron, butterfly valve
complete with C.I. body, EPDM disc seal, SS retainer ring, carbon
1.3
steel disc & shaft and lever conforming to BS 5155 and suitable for PN
16 including companion flanges.
a) 100 mm dia Nos. 28 6,930 194,040

Providing and fixing double flanged cast iron type Dual plate spring
1.4 operated Check valve conforming to API 596/598 with CI body, CS
plate & SS spring & suitable for 16 kg /cm2. with companion flanges.

a) 100 mm dia Nos. 28 8,989 251,692

Gun-metal Fire Brigade inlet connection for connecting to fire hydrant


ring main consisting of 2 Nos. 63mm dia instantaneous type male
1.5 Each 24 34,343 824,232
couplings with built-in check valves and 100mm dia, flanged outlet
complete with bolts, nuts, and rubber insertions as per requirement.

SUB TOTAL - SECTION 1 2,199,083


SECTION 2 - INTERNAL FIRE FIGHTING WORKS
FIRE DOWNCOMMER SYSTEM/ DRY RISER

Providing, fixing and testing black mild steel G.I. Heavy duty (Class 'C')
pipes (IS:1239) and fitting like flanges, tees, elbows, bend junctions,
2.0
reducers etc, clamp structural steel supports as required / directed at
site including cutting and making all comp.

a) 25mm dia Rmt 46 402 18,492


b) 65mm dia Rmt 833
c) 80mm dia Rmt 47 1,027 48,269
d) 100mm dia Rmt 353 1,378 486,434
Providing & fixing 63 mm dia 2 nos. x 7.5 mtr. Long Reinforced rubber
lined hose pipe with 20 mm bore nozzle including gunmetal male &
2.1 Nos. 66 10,305 680,130
female instantaneous type coupling & branch pipe approved by fire
authority.

Providing & fixing fire single headed internal hydrant valve with
instantaneous Gun metal couplings of 63mm dia cast iron wheel ISI
2.3 Nos. 66 7,374 486,684
marked conforming to IS 5290 (Type-A) with blank Gunmetal cap and
chain as required.

Supplying and fixing TAC approved first aid hose reel including 30
meter long 20mm internal dia rubber lined hose reel tubing, 25 mm dia
stop valve, shut off nozzle of sufficient length at one end of this hose
2.4 Nos. 66 7,782 513,612
and leaded tin, bronze rings and adapter to get in to the instanta-neous
female coupling complete with suitable drawn brackets, hub etc as
required. the hose reel strictly confirm to IS:884 - 1985

S.S. 304 Cabinet (to enclose above draw-out connection) fabricated


from 16g sheet with full front glass door and locking arrangement duly
2.5 painted with one coat of primer and two or more coats of synthetic Nos. 66 5,537 365,442
enamel paint of approved make and shade and suitably mounted on
wall as required (size . 750 mm x 600mm x 450mm).

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
50 of 55
Sr. No. Item Description Unit Quantity Rate Amount
Providing and fixing fire authority approved ball valves with S.S. ball,
2.6
PN 16 including all fittings required.
a) 25mm dia Nos. 86 818 70,348
Providing and fixing cast iron butterfly valves with EPDM seat
2.7 projection conforming to IS 5155, PN 16 including pipe flanges
complete in all respect.
a) 100 mm dia Nos. 37 6,930 256,410
Providing, fixing, testing and commissioning of single acting 25mm
2.8 dia., air release valve with all accessories,PN 16 including pipe flanges Nos. 31 1,663 51,553
complete in all respect
SUB TOTAL - SECTION 2 2,977,374
SECTION 3 - AUTOMATIC SPRINKLER SYSTEM

Providing and fixing of G.I. heavy duty (Class 'c' pipes (IS:1239 Part -
1), and fitting like flanges (MS steel flanges at every 15m length and as
required tees, elbows, bends, junctions, Reducers etc; clamps/
3.0 structural steel supports as required/directed at site including cutting &
making good the walls, RCC work etc. cutting chases & filling the
came with cement conc. 1:3:6 including painting the exposed pipes
with desired shade of enamel over a coat of primer.

a) 25mm dia Rmt 802 402 322,404


b) 32mm dia Rmt 122 449 54,778
c) 40mm dia (Including Drain Pipe) Rmt 234 519 121,446
d) 50mm dia Rmt 180 670 120,600
e) 65mm dia Rmt 152 833 126,616
f) 80mm dia Rmt 7 1,027 7,189
g)100mm dia Rmt 1,378
Providing and fixing fire authority approved ball valves with S.S. ball
3.1
including all fittings required.
a) 20mm dia Nos 576
b) 25mm dia Nos 23 818 18,814
15mm dia, Quartzoid bulb type G.M. Spinkler Head
(Pendent/Upright/Conventional, as required) set to operate at 68 C
3.2 Nos 332 425 141,100
(UL/FM/LPC/TAC listed/ approved chrome plated complete with
decorating plate (Ressette).

Providing, fixing, testing and commissioning 40mm diameter pipe with


3.3 inspecting and testing assembly with gunmetal isolation valve Nos 13 7,434 96,642
gunmetal sight glass bypass valve
Providing, fixing, testing and commissioning 50mm diameter drain
3.4 Nos 6 3,525 21,150
valve
3.5 Flow Switches for each sprinkler tapping from riser complete with all acc Nos 13 5,621 73,073
SUB TOTAL - SECTION 3 1,103,812
SECTION 4 - FIRE PUMPS AND ACCESSORIES

Supply, Erection, testing and commissioning of centrifugal monoblock


pump of approved make,which gives a discharge of 450 LPM of 40
mtrs head,with suitable electrical driven motor when running at 2900
rpm. When directly coupled to suitable HP TEFC motor also provision
threaded coupling in suction and discharge lines for tubing. Including
pump electric panel Sheet steel clad floor mounting control panel.
control of 10 HP fire pumps, booster pumps having incoming isolating
switch, branch HRC fuses, incoming voltmeter with selector switch and
4.0 Set 5 87,081 435,405
fuses, auto star delta starters with hand reset overload cum single
phase preventor type relay for fire pump and DOL starters with hand
reset overload cum single phase preventor type relay for booster
pumps, ammeters to read current in any one phase,
OFF/AUTO/MANUAL selector switches, various fault indicating lights
such as pump trip due to overload, pressure switches,pressure gauge,
fuse blow out etc., and alarms with hand reset push button which will
automatically reset for the next cycle.

The alarm shall start when the fire hydrant starts on fire duty. The fire
pump once started shall run continuously till manually switched off.

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
51 of 55
Sr. No. Item Description Unit Quantity Rate Amount
SUB TOTAL - SECTION 4 435,405

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd.Page
02.12.09
52 of 55
ANNEXURE - I
RATES OF ADDITIONAL ITEMS
Sr. N0. Item description Unit Quantity Rate

1.16.a Same as item 1.16 above but using manufactured sand conforming to QRO Cum 855
relevant I.S. codes

1.18.b.1 Rebate over item 1.18.a.1 for using rubble available on site on as-is- QRO Cum 340
where-is basis. Rate shall include necessary cutting & sizing as
required.

1.18.b.2 Rebate over item 1.18.a.2 for using rubble available on site on as-is- QRO Cum 337
where-is basis. Rate shall include necessary cutting & sizing as
required.
2.01.3.a Same as item 2.01.3 but using manufactured sand conforming to QRO Cum 3 296
relevant I.S. codes in suitable proportion with river sand, based on mix
design with prior approval from consultants, subject to proportion of
manufactured sand not exceeding 67% of river sand.

2.01.4.a Same as item 2.01.4 but using manufactured sand conforming to QRO Cum 3 028
relevant I.S. codes in suitable proportion with river sand, based on mix
design with prior approval from consultants, subject to proportion of
manufactured sand not exceeding 67% of river sand.

2.01.5.a Same as item 2.01.5 but using manufactured sand conforming to QRO Cum 2 789
relevant I.S. codes in suitable proportion with river sand, based on mix
design with prior approval from consultants, subject to proportion of
manufactured sand not exceeding 67% of river sand.

2.12.1.a Same as item 2.12.1 but using manufactured sand conforming to QRO Cum 4 150
relevant I.S. codes in suitable proportion with river sand, based on mix
design with prior approval from consultants, subject to proportion of
manufactured sand not exceeding 67% of river sand.

2.13.1.a Same as item 2.13.1 but using manufactured sand conforming to QRO Cum 4 368
relevant I.S. codes in suitable proportion with river sand, based on mix
design with prior approval from consultants, subject to proportion of
manufactured sand not exceeding 67% of river sand.

2.14.a1.a Same as item 2.14.a1 but using manufactured sand conforming to QRO Cum 4 618
relevant I.S. codes in suitable proportion with river sand, based on mix
design with prior approval from consultants, subject to proportion of
manufactured sand not exceeding 67% of river sand.

4.11.a Rebate over item 4.11 for using rubble available on site on as-is- QRO Cum 340
where-is basis
4.13.a Rebate over item 4.13 for using rubble available on site on as-is- QRO Cum 339
where-is basis
4.14.a Rebate over item 4.14 for using rubble available on siteon as-is-where- QRO Cum 339
is basis
9.39.a Same as item 9.39 above but fixing tile with cement based polymer QRO sqm 1 331
adhesive like BAL or equivalent instead of 1:1 cement: sand mortar.

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09

Page 53 of 55
ANNEXURE - II

Sr. N0. Item description Unit Quantity Rate


RATES OF ADDITIONAL ITEMS
Civil Works:
2.09.b.1 Same as item 2.09.b but using manufactured sand conforming to Cum QRO 6 923
relevant I.S. codes in suitable proportion with river sand, based on
mix design with prior approval from consultants, subject to
proportion of manufactured sand not exceeding 67% of river sand.

2.09.b.2 Same as item 2.09.b but with minimum cement 288 Kg per cum + Cum QRO 6 691
flyash in required proportion.
2.12.1.b Same as item 2.12.1 but with minimum cement 260 Kg per cum + Cum QRO 4 074
flyash in required proportion.
2.13.1.b Same as item 2.13.1 but with minimum cement 288 Kg per cum + Cum QRO 4 136
flyash in required proportion.
2.14.a1.b Same as item 2.14.1 but with minimum cement 320 Kg per cum + Cum QRO 4 292
flyash in required proportion.
9.06.a 50 mm thick marble chips flooring (in-situ terrazzo flooring) rubbed Sqm QRO 1 292
and polished with different grade emery stones to achieve mirror
finish as per the drawing and design, under layer 38 mm thick
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 12.5 mm nominal size) and top layer 12mm thick with
marble chips of colour and sizes from 7mm to 10mm nominal size
laid in white cement marble powder mix 3:1 (3 white Cement : 1
marble powder) by weight in proportion of 2:3 (2 cement marble
powder mix : 3 marble chips) admixed with non-fading pigment of
approved shade and make by volume including cement slurry,
placing the homogenous mix in alternate panels and panels being
formed with glass strips and finishing the panels with approved
colour pigments. The rate shall be inclusive of mirror polishing of the
panels with different emery stones including cleaning with oxalic acid
or as directed by engineer in charge. (NO WAXING SHALL BE
PERMITTED). The rate should also include the covering & protecting
of flooring with plastic + POP or as required after completion of the
item until handing over to client and removing the same at the time
of handing over.

9.06.b 55 mm thick pebbled concrete using 10-15mm rounded river Sqm QRO 780
pebbles of approved shades as per design, under layer 40 mm thick
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 12.5 mm nominal size) and 15mm thick top layer using
10-15mm rounded pebbles laid in white cement admixed with
approved shade and make non-fading pigment, including cleaning
with water & oxalic acid as directed by engineer in charge.

9.12.a Providing & laying average 25 mm thick stone of following type of


approved quality, selected and sorted for uniform colour, in floor,
otta, sill, skirting, tread, riser etc., in required sizes upto 60 cm. as
per design and drawings (with grooves). Kota stone to be laid over
cement mortar 1:6 bedding of average 35 to 40 mm thickness with
joints, pointing and making grooves as specified, including curing
and cleaning upto the satisfaction of the Architect & Engineer-in-
charges etc. complete. (NO WAXING WILL BE PERMITTED). The rate
should include the covering & protecting of flooring with plastic +
POP or as required after completion of the item until handing over to
client and removing the same at the time of handing over.

9.12.a.4 Teak / Rainbow Sand Stone of 40mm thickness having Natural Sqm QRO 1 608
Finish.
9.12.a.5 Natural Slate Stone of 10-15mm thickness having Natural Finish of Sqm QRO 1 036
approved shade like red, peacock, rainbow, multi colour etc.
9.21 Providing & laying Flat, irregular natural sand stone (Agra red, Sqm QRO 1 996
Dholpur pink etc.) pieces 25-30 mm thick, roughly 600x600 mm size
of approved shade and quality, selected and sorted in floor as per
design in crazy pattern (with grooves). Stone is to be laid over
cement mortar 1:6 bedding of 35 to 50 mm thickness including
pointing with epoxy grout of approved shade in joints, curing and
cleaning upto the satisfaction of the Architect & Engineer-in-charge
etc. complete. The work shall be carried out as per the approval of
architect and satisfaction of engineer in charge. The rate should
include the covering & protecting of flooring with plastic + POP or as
required after completion of the item until handing over to client and
removing the same at the time of handing over.

9.34.a.1 Same as item 9.34.a but using manufactured sand conforming to Cum QRO 4 282
relevant I.S. codes in suitable proportion with river sand, based on
mix design with prior approval from consultants, subject to
proportion of manufactured sand not exceeding 67% of river sand.

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09 Page 54 of 55
Sr. N0. Item description Unit Quantity Rate
9.34.a.2 Same as item 9.34.a but with minimum cement 260 Kg per cum + Cum QRO 4 206
flyash in required proportion.
9.41 Providing & fixing dado or cladding of following type of stone on wall
for all heights having specified thickness and size with grooves
(10mm) in both direction, filling the grooves with epoxy grout of
matching shade as per detail design and drawing. The stone shall be
fixed over 12 to 15 mm thick wired finish plaster in cement mortar
1:4 (1 cement : 4 coarse sand). The stone shall be fixed in 1:1
cement mortar. The rate shall also include backing coat wired finish
plaster of average 15 mm thick in cement mortar 1:4 (1 cement : 4
coarse sand). The work shall be carried out as per the cladding
sample approved by Architect and engineer in charge.

a. Slate 10-15 mm thick, upto 600 mm size Sqm QRO 1 323


b. Sand stone (Agra red, Dholpur pink etc.), 25-30mm thick, size upto Sqm QRO 1 945
600mm
c. Granite Sqm QRO 3 561
Electrical Works:
21.1 One fan point controlled by two, two way 6 A switches and hum free No. QRO 2 074
electronic type step regulator.
Fire fighting Works:
5.1 Providing and fixing double flanged cast iron, Sluice valve complete No. QRO 10 180
with C.I. body, EPDM disc seal, SS retainer ring, carbon steel disc &
shaft and lever conforming to BS 5155 and suitable for PN 16
including companion flanges.
a. 100 mm dia
5.2 Providing and fixing double flanged cast iron type Non-return valve
conforming to API 596/598 with CI body, CS plate & SS spring &
suitable for 16 kg /cm2 with companion flanges.
a. 100 mm dia No. QRO 8 943
5.3 Providing and fixing fire authority approved bronze ball valves with
all fittings required.
a. 65 mm dia No. QRO 5 252
5.4 Providing, fixing, testing and commissioning 40mm diameter drain No. QRO 1 793
valve.
5.5 Providing, fixing, testing and commissioning 100mm diameter pot No. QRO 17 741
strainer.

Please read this BOQ in conjunction with our covering Letter vide ref:SPCL/HYD/AKA-Main/Offer/09/09 dtd. 02.12.09 Page 55 of 55