You are on page 1of 5

Check Schedule

Item Date Checker Contact Email


Early Thermal 10-May-07 Tayeb Kazemi Tayeb.kazemi@stskconsulting.co.uk
Comments
first issue
Disclaimer

The originator does not guarantee the accuracy of the output or


any other information on this spreadsheet. The users take all
responsiblity for the use of this spreadsheet, modifications and
output. Should you experience any problems or like to see more
features added to this spreadsheet please contact:
tayeb.kazemi@stskconsulting.co.uk

This spreadsheet is free and you may print or download this


spreadsheet to a local hard disk for your personal and non-
commercial use only. You may transfer the spreadsheet to
individual third parties for their personal use, but only if you
acknowledge STSK Consulting Ltd or the website as the source of
the material.
DOCUMENT No.(Project / Doc) SHEET No.

© STSK Consulting Ltd DATE:


SUBJECT
PREPARED BY:

REF CALCULATIONS OUTPUT

EARLY THERMAL CRACKING


BD 28/87 ( f ct ) ¿

CL. 5.1 A s= Ac
fy
As = 3142 mm² ( B 20 @ 100 )
Ac = 250000 mm² ( 250 X 1000 )
fy = 500 N/mm²
fcu = 45 N/mm²
0.7
f ct =0 .12( f cu )0 .7 = 0.12 x ( 45 ) = 1.724 N/mm²

1.724
As = x 2.5E+05 = 861.8 mm²
500 O.K.

( f ct ) A c φ
¿
CL. 5.8 A s= × [ R(ε sh+ε th )−0. 5 ε ult ]
Table 1 fb 2w
CL. 5.7
w = 0.2 mm (permissible crack width)
CL.5.11 f = 20 mm (bar size (nominal diameter))
Table 2 R = 0.5 Deck cast in stages or internal

fb = fct * / 0.67 = 2.57 N/mm²

esh = 0.5 eult = 0.0001


eult = 2.0E-04

BD 28/87 ε th=0. 8 α (T 1 +T 2 )
CL. 5.7
eth = 0.8 x 1.2E-05 x( 35 + 0 ) = 3.4E-04

CL. 5.7 T1 = 35 oc
CL. 5.7 T2 = 0 oc
a = 1.20E-05 per o
c

1.72 3E+05 x 20
As = x [ 0.5 x ( 1.0E-04 + 3.4E-04 ) - 0.5 x 2.0E-04 ]
2.57 2 x 0.20

= 988 mm² < 3142


O.K.
Use B 20 @ 100