1 contents. The parameter set can be transferred to a PC or (also note software version in r060.001 and programming device by means of SIMOVIS r065.001!) (see also Section 15).
Switch off electronics power supply
2
Connect one COM port on the PC to Cable order number: 6SX7005-0AB00
3 connector X300 on the converter (see also Section 15.3)
Switch on electronics power supply AND press Note:
4 down the UP key on the PMU of the A software update can be started only from the SIMOREG converter at the same time PMU panel and not via an OP1S or the SIMOVIS ⇒ The SIMOREG converter switches to system operating state o13.0
Open a DOS window on the PC and enter Note:
5 program call: HEXLOAD.EXE: Loading program HEXLOAD 7001Axxx.H86 7001Bxxx.H86 COMx 7001Axxx.H86 and 7001Bxxx.H86: Start the program by pressing Return Data files which contain the SIMOREG software ⇒ The software update is performed xxx is the SW release automatically COMx: COM1 or COM2
⇒ When the software has been updated Note:
6 successfully, the SIMOREG switches to The currently programmed addressed is displayed operating state o13.2 for approx. 1 s on the PMU while the update is in progress ⇒ The SIMOREG converter then switches to The current status of the update routine is operating state o12.9 in many cases displayed on the PC (depending on which SW version was previously installed in the converter) for approximately 15s.
Checking the checksum:
7 Compare the value of parameter r062.001 with the checksum in the Internet under menu item "Info" (refer to the inside of the cover sheet of the operating instructions in this regard)
Was SW version 1.0 or 1.1 previously
8 installed in the converter or was the ? yes electronics supply disconnected while Step 6 was in progress? Acknowledge any fault message that may 9b appear on the SIMOREG device.
n Restore default setting
o 10b (see Section 7.4)
Start up the converter again
11b (see Section 7.5) Note: The parameter set stored in Step 1 above can be loaded from a PC or programming device by means of SIMOVIS.