You are on page 1of 1

Table 4: Partial safety factors [According to IS: 800 (2007)]

Type of Maximum
Deflection Design Load Member Supporting
Building Deflection
Live load/Wind Purlins and Girts Elastic cladding Span / 150
load Purlins and Girts Brittle cladding Span / 180
Live load Simple span Elastic cladding Span / 240
Live load Simple span Brittle cladding Span / 300
Live load Cantilever span Elastic cladding Span / 120
Live load Cantilever span Brittle cladding Span / 150
Vertical

Live load or Profiled Metal Sheeting Span / 180


Rafter supporting
Wind load Plastered Sheeting Span / 240
Crane load Gantry Crane Span / 500
(Manual operation)
Industrial building

Crane load
(Electric operation Gantry Crane Span / 750
up to 50 t)
Crane load
(Electric operation Gantry Crane Span / 1000
over 50 t)

No cranes Column Elastic cladding Height / 150

No cranes Column Masonry/Brittle cladding Height / 240

Crane + wind Gantry (lateral) Crane(absolute) Span / 400


Lateral

Relative displacement
10 mm
between rails
Column/frame Gantry (Elastic cladding; Height / 200
pendent operated)
Crane+ wind
Column/frame Gantry (Brittle cladding; Height / 400
cab operated)
Elements not susceptible
Live load Floor & Roof Span / 300
to cracking
Elements susceptible to
Vertical

Live load Floor & Roof Span / 360


cracking
Other Buildings

Elements not susceptible


Live load Span / 150
to cracking
Cantilever
Elements susceptible to
Live load Span / 180
cracking
Elastic cladding Height / 300
Wind Building
Lateral

Brittle cladding Height / 500


Storey height
Wind Inter storey drift ---
/ 300

4-9