Professional Documents
Culture Documents
AS IS (Technology) TO BE (Technology)
(2G Rak) (3G/4G Rack)
e installed.
3900L (New empty rack) + [BB 3900 & 6*GRFU (900&1800) (From Dismantling)] / [BB 3910
2G Huawei 2G Huawei 3012 - Indoor Indoor 3012 + (Feeder G1800) -
(UBRI+UMPT.b1) + 3*MRFU + 3*RRU 3953]
3900A (New empty rack) + [BB 3900 & 6*GRFU (900&1800) (From Dismantling)] / [BB 3910
2G Huawei 2G Huawei 3012 - Indoor Outdoor Shelter + BTS + DC Power + (Feeder G1800) -
(UBRI+UMPT.b1) + 3*MRFU + 3*RRU 3953] + IBBS 200T (From Dismantling)
2G Huawei 2G + 3G + 4G Huawei 3012 - Indoor Indoor 3012 + Feeder G1800 3900L (Configured based on LOM) + 3*RRU 3953 All in 3900L
2G Huawei 2G + 3G + 4G Huawei 3012 / 3900 / 3900L - Indoor Outdoor Shelter + BTS + DC Power + Feeder G1800 3900A (Configured based on LOM) + 3*RRU 3953 + MTS 9000A All in 3900A
2G Huawei 2G + 3G + 4G Huawei 3900 - Indoor Indoor 6*GRFU + Feeder G1800 TRS 19" Rack(if not exist) + BB 3910 (UBBP.d6+UMPT.b1) + 3*MRFU + 3*RRU 3953 All in 3900
2G Huawei 2G + 3G + 4G Huawei 3900L - Indoor Indoor 6*GRFU + Feeder G1800 Unit (BB 3910 (UBBP.d6+UMPT.b1) + 3*MRFU) + 3* RRU 3953 All in 3900L
6*GRFU
2G Huawei 2G + 3G + 4G Huawei 3900A + IBBS 200T - Outdoor Outdoor +IBBS 200T (to be reused) + Feeder G1800 Unit (BB 3910 (UBBP.d6+UMPT.b1)+3*MRFU)+3*RRU 3953 + MTS 9000A All in 3900A
2G Huawei 2G + 3G + 4G Huawei 3900AL+ IBBS 700T - Outdoor Outdoor 6*GRFU + Feeder G1800 Unit (BB 3910 (UBBP.d6+UMPT.b1)+3*MRFU)+3*RRU 3953 All in 3900A
2G + 3G (4G) Huawei 2G + 3G + 4G Huawei 3900 19" Rack Indoor Indoor BB 3900 + 6*GRFU + Feeder G1800 Unit (BB 3910 (UBBP.d6+UMPT.b1)+3*MRFU)+3*RRU 3953 All in 3900 + 19" Rack
2G + 3G (4G) Huawei 2G + 3G + 4G Huawei 3900 Within 2G Rack Indoor Indoor BB 3900 + 6*GRFU + Feeder G1800 Unit (BB 3910 (UBBP.d6+UMPT.b1)+3*MRFU)+3*RRU 3953 All in 3900 + 19" Rack
2G + 3G (4G) Huawei 2G + 3G + 4G Huawei 3900L Within 2G Rack Indoor Indoor BB 3900 + 6*GRFU + Feeder G1800 Unit (BB 3910 (UBBP.d6+UMPT.b1)+3*MRFU)+3*RRU 3953 All in 3900L
2G + 3G (4G) Huawei 2G + 3G + 4G Huawei 3900 / 3900L 19" Rack Indoor Outdoor Shelter + BTS + DC Power + Feeder G1800 3900A (Configured based on LOM) + 3*RRU 3953 + MTS 9000A All in 3900A
2G + 3G (4G) Huawei 2G + 3G + 4G Huawei 3900A + IBBS 200T TP48200A (DBS) Outdoor Outdoor BB 3900 + 6*GRFU + Feeder G1800 Unit (BB 3910 (UBBP.d6+UMPT.b1)+3*MRFU)+3*RRU 3953 All in 3900A + DBS
2G + 3G (4G) Huawei 2G + 3G + 4G Huawei 3900AL + IBBS 700T Within 2G Rack Outdoor Outdoor BB 3900 + 6*GRFU + Feeder G1800 Unit (BB 3910 (UBBP.d6+UMPT.b1)+3*MRFU)+3*RRU 3953 All in 3900AL
AS IS TO BE AS IS
(Technologies) (Technologies) (2G Rack)
Huawei V-pol / X-pol / 2X-pol (Low Gain) G900+G1800+(U900)+(L1800) 2X-pol (High Gain) Antenna Change + RET installation & commissioning (for all technologies)
Huawei 2X-pol (High Gain) G900+G1800+(U900)+(L1800) 2X-pol (High Gain) RET installation & commissioning (for all technologies)
Huawei 2X-pol (G900/1800-Low Gain) + 2X-pol (U2100/L2600) G900+G1800+U2100+(L2600)+(U900)+(L1800) 2X-pol (High Gain) + 2X-pol (U2100/L2600) Antenna Change + RET installation & commissioning (for all technologies)
Huawei 2X-pol (G900/1800-High Gain) + 2X-pol (U2100/L2600) G900+G1800+U2100+(L2600)+(U900)+(L1800) 2X-pol (High Gain) + 2X-pol (U2100/L2600) RET installation & commissioning (for all technologies)
Huawei 3X-pol / 4X-pol G900+G1800+U2100+(L2600)+(U900)+(L1800) 3X-pole / 4X-pol RET installation & commissioning (for all technologies)
Huawei 5X-pol / 4X-pol (Dual 900) G900+G1800+U2100+(L2600)+(U900)+(L1800) 5X-pol / 4X-pol (Dual 900) RET commissioning (for all technologies)
Ericsson V-pol / X-pol / 2X-pol G900+G1800+(U900)+(L1800) 4X/5X-pol Antenna Change + RET commissioning (for all technologies)
Ericsson 2X-pol (G900/1800) + 2X-pol (U2100/L2600) G900+G1800+U2100+(L2600)+(U900)+(L1800) 3X-pol + 2X-pol (U2100/L2600) Antenna Change + RET installation & commissioning (for all technologies)
Ericsson 3X-pol / 4X-pol (Dual 900) (G900/1800+U2100) G900+G1800+U2100+(U900)+(L1800) 4X/5X-pol Antenna Change + RET commissioning (for all technologies)
Ericsson 3X-pol / 4X-pol (Dual 900) (G900/1800) G900+G1800+(U900)+(L1800) 3X-pol / 4X-pol (Dual 900) (G900/1800) RET installation & commissioning (for all technologies)
Ericsson 4X-pol (G900/1800)+U2100 G900+G1800+U2100+(U900)+(L1800) 4X-pol (G900/1800)+U2100 RET commissioning (for all technologies)
Ericsson 4X-pol (G900/1800)+U2100+L2600 G900+G1800+U2100+L2600+(U900)+(L1800) 5X-pol Antenna Change + RET commissioning (for all technologies)
Ericsson 5X-pol (G900/1800+U2100+(L2600) G900+G1800+U2100+(L2600)+(U900)+(L1800) 5X-pol (G900/1800+U2100+(L2600) RET commissioning (for all technologies)
Nokia V-pol / X-pol / 2X-pol G900+G1800+(U900)+(L1800) 4X-pol Antenna Change + RET commissioning (for all technologies)
Nokia 2X-pol (G900/1800) + 2X-pol (U2100) G900+G1800+U2100+(L2600)+(U900)+(L1800) 3X-pol + 2X-pol (U2100) Antenna Change + RET installation & commissioning (for all technologies)
Nokia 3X-pol / 4X-pol (Dual 900) (G900/1800+U2100) G900+G1800+U2100+(U900)+(L1800) 4X-pol Antenna Change + RET commissioning (for all technologies)
Nokia 3X-pol / 4X-pol (Dual 900) (G900/1800) G900+G1800+(U900)+(L1800) 3X-pol / 4X-pol (Dual 900) (G900/1800) RET installation & commissioning (for all technologies)
Nokia 4X-pol (G900/1800)+U2100 G900+G1800+U2100+(U900)+(L1800) 4X-pol (G900/1800)+U2100 RET commissioning (for all technologies)
Nokia 5X-pol (G900/1800)+U2100 G900+G1800+U2100+(U900)+(L1800) 5X-pol (G900/1800+U2100 RET commissioning (for all technologies)
Assumption:
1- RET installation for urban sites are in high priority.
2- 2X-pol (Low Gain) = 14-16 dB
3- 2X-pol (High Gain) = 17-18 dB