SUBMITTAL AM528JXVAJH2AA
Samsung DVM S Series, Heat Pump Condensing Unit
Job Name Location
Purchaser Engineer
Submitted to Reference Approval Construction
Unit Designation Schedule #
System Specifications
Module 1 AM168HXVAJH2AA
Modules
System Module 2 AM168HXVAJH2AA
Connected
Module 3 AM192HXVAJH2AA
US Ton (nominal) 44
Nominal / Rated Cooling1 528,000 / 500,000
Capacity (Btu/h)
Nominal / Rated Heating1 594,000 / 560,000
Performance
EER Ducted / Non-Ducted 9.50 / 9.50
IEER Ducted / Non-Ducted 16.00 / 19.00
High Heat COP Ducted / Non-Ducted 3.20 / 3.20
Safety Certifications ETL (UL 1995) Flash injected compressors provide advanced low ambient heating performance.
Intelligent logic to ensure proper operation within unit design limitations and Subcooling devices in system maintain capacity at extreme system refrigerant pipe lengths and
operational parameters. minimize refrigerant noise.
High pressure sensor, low pressure sensor, over-voltage protection, compressor
over- current protection, current transformer, fan motor voltage protection, fan motor Other Features
Protection Devices Asymmetrical scroll design with rotating compressor operation/priority (where applicable).
thermal protection, overheat protection, phase detection protection, high voltage
fuses Advanced oil recovery cycle logic (maximum duration in cool mode: 3 minutes, maximum duration in
Inverter PCB cooling done with liquid refrigerant to maintain optimal and safe heat mode: 6 minutes, defrost cycles lasting over 3 minutes are considered oil recovery cycles). Oil
operating temperatures. recovery operation shall not interrupt heating or cooling operation.
Accessories Optional night quiet modes to reduce outdoor unit sound (4 levels) with automatic activation or
Qty. Model Number Description manual activation (with MIM-B14).
1 MXJ-TA3819M Outdoor unit tee (liquid and suction fittings, ≤ 461,000 Btu/h ) Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by monitoring air
resistance across the condenser coil during heating operation to determine defrost operation
1 MXJ-TA4422M Outdoor unit tee (liquid and suction fittings, ≥ 478,400 Btu/h)
initiation to prevent unnecessary defrost cycles.
WHG-T2 Top wind/hail guard (8 - 18 ton outdoor units)
Optional snow blowing logic to prevent snow accumulation on idle outdoor units
WHG-SL Left side wind/hail guard (6 - 16 ton outdoor units)
Maximum current control of outdoor unit(s) to limit current (50% - 100% of design current)
WHG-SR Right side wind/hail guard (6 - 16 ton outdoor units) adjustable at outdoor unit or central control devices: DMS 2.5 (MIM-D01AUN), BACnet Gateway
(MIM-B17BUN), LON Gateway (MIM-B18BUN).
WHG-R2 Rear wind/hail guard (8 - 16 ton outdoor units)
Low ambient cooling hood and side guards (large chassis, 3 required)
Energy savings options to reduce system energy consumption when average indoor room temperatures
LACH-2-KIT
are greater than average indoor set temperatures in heating mode or when average indoor room
Low ambient cooling side guards (8 - 16 ton outdoor units)
temperatures are lower than average indoor set temperatures in cooling mode.
LACH-2-SIDE KIT
MCM-C200U Heat pump mode selector switch Samsung HVAC maintains a policy of ongoing development, specifications are subject to change
without notice.
External contact control interface module (operation and error output,
MIM-B14 * Restrictions apply. Design above 130% requires an engineering review for approval. Refer
night silent mode manual activation)
to the Technical Data Book for more information.
1 Certified
in accordance with the AHRI Variable Refrigerant Flow Multi-Split Air-Conditioners and Heat Pump (VRF) Certification
Program which is based on the latest edition of AHRI Standard 1230.
2 Other pipe restrictions and requirements exist. Please consult technical data book or installation manuals for full details regarding
limitations and other requirements for vertical separation over 163 feet (outdoor to lowest indoor).
3 When outdoor unit is lower than indoor units, and vertical separation is greater than 131 feet, additional conditions apply. Please
refer to supporting documents at www.SamsungHVAC.com.
4 When operating in cooling mode between -13°F and 5°F OA, LACH-2-KIT is required. When operating in cooling mode between 5°F
and 23°F OA, LACH-2-SIDE KIT is required. Refer to technical bulletin at www.samsunghvac.com for full details and requirements.
Module Specifications
Module Model Number AM168HXVAJH2AA AM168HXVAJH2AA AM192HXVAJH2AA
US Ton (nominal) 14 14 16
Nominal / Rated Cooling1 168,000 / 160,000 168,000 / 160,000 192,000 / 184,000
Performance Capacity (Btu/h)
Nominal / Rated Heating1 189,000 / 180,000 189,000 / 180,000 216,000 / 206,000
Compressor Modulation Down to Btu/h 7,513 7,513 7,513
Pipe Connections Liquid X Suction (inches) inches 5/8 X 1 1/8 5/8 X 1 1/8 5/8 X 1 1/8
www.SamsungHVAC.com
3 of 3 Page
SUBMITTAL AM528JXVAJH2AA
Samsung DVM S Series, Heat Pump Condensing Unit
AM168HXVAJH2AA, AM192HXVAJH2AA Dimensional Drawing
51"
30 1/8"
1 7/16"
66 3/4"
26 13/32"
24 1/4"
21 15/16"
19 3/8"
4 13/16"
9 1/2"
6 3/4"
4 1/4"
LEFT SIDE RIGHT SIDE
2"
7 15/16"
45 1/4"
22 5/8"
29 31/32"
31 5/8"
51"
BOTTOM