SPB 30

Mounted on 20m column


and heavy duty cross frame

20m

Foundation

without counterweight / with quick connection on boom 1

SPB30 WIND WINDFORCE MOMENT VERTICAL LOAD WIND FORCES TORQUE FORCES FORCES
direction q/ kN/m 2 Me / kNm V / kN W / kN Md / kNm Ed / kN Ez / kN
in operation X 0,3 884,5 171,6 7,4 55 319,3 233,5
in operation Y 0,3 811,6 171,6 11,6 55 296,5 210,7
out of operation X 1,1 496,3 141,1 27,1 0 190,4 119,8
out of operation Y 1,1 584,1 141,1 42,5 46 217,8 147,3

foundation loads with factores according to DIN 24117

with counterweight / with quick connection on boom 1

SPB30 WIND WINDFORCE MOMENT VERTICAL LOAD WIND FORCES TORQUE FORCES FORCES
direction q/ kN/m 2 Me / kNm V / kN W / kN Md / kNm Ed / kN Ez / kN
in operation X 0,3 621,5 237,1 8,3 53 253,5 135
in operation Y 0,3 608,7 237,1 12,3 2 249,5 131
out of operation X 1,1 233,3 206,6 30,4 0 124,6 21,3
out of operation Y 1,1 506,8 206,6 45 36 210 106,7

foundation loads with factores according to DIN 24117


SPB 30
Mounted on 20m column
and supported on floor frames

without counterweight / with quick connection on boom 1

SPB30 WIND WINDFORCE MOMENT VERTICAL LOAD HORIZONTAL LOADS FORCES


direction q/ kN/m 2 Me / kNm V / kN Ho / kN Hu / kN Md / kNm
in operation X 0,3 858,9 161,3 250,9 245,4 55
in operation Y 0,3 804,7 161,3 239,4 229,9 55
out of operation X 1,1 402,5 130,8 135,3 115 -
out of operation Y 1,1 439 130,8 160 125,4 46

foundation loads with factores according to DIN 24117

with counterweight / with quick connection on boom 1

SPB30 WIND WINDFORCE MOMENT VERTICAL LOAD HORIZONTAL LOADS FORCES


direction q/ kN/m 2 Me / kNm V / kN Ho / kN Hu / kN Md / kNm
in operation X 0,3 612,9 226,8 181,5 175,1 53
in operation Y 0,3 604,5 226,8 182,8 172,7 15
out of operation X 1,1 156,5 196,3 68,3 44,7 -
out of operation Y 1,1 365 196,3 141,4 104,3 36

foundation loads with factores according to DIN 24117