You are on page 1of 1

HILTI-HIT RE100 Injection Adhesive with Rebar application

Summary of drill depth for design considerations for slab/beam to wall/column

Adhesive used : Hilti HIT-RE 100

Steel Strength fyk 500 N/mm²


Class of Concrete G 40 N/mm²

Bar Size mm 16 20 25 32 40
Sectional area of bars mm² 201 314 491 804 1257
Spacing mm 200 200 200 200 200

Anchorage min embedment mm 165 206 258 330 447


Length: Iinst Maximum at 50% capacity mm 193 241 301 417 633

Loads per bar for min embedment kN/bar 37.4 58.5 91.2 138.6 193.1
Design yield kN/bar 43.7 68.3 106.7 174.9 273.1

Notes:
1. Assumed slab/beam to wall/column application (Pin Connection).
2. Assumed min. bar spacing as indicated in the table above
3. Assumed min. concrete cover as indicated in the table above
4. Please refer to attached PROFIS Rebar calculation reports.
5. T12 rebar assumed due to the limitation of software. Please adhere to the edge and spacing and embedment depth for T13 rebar

You might also like