You are on page 1of 1

HILTI-HIT RE500V3 Injection Adhesive with Rebar application

Summary of drill depth for design considerations for beam to column

Adhesive used : Hilti HIT-RE 500V3

Steel Strength fyk 500 N/mm²


Class of Concrete G 40 N/mm²

Bar Size mm 16 20 25 32 40
Sectional area of bars mm² 201 314 491 804 1257
Spacing mm 110 100 100 100 100

Anchorage min embedment mm 165 206 258 330 447


Length: Iinst Maximum at 75% capacity mm 266 400 549 751 1089

Loads per bar for min embedment kN/bar 37.4 58.5 91.2 138.6 193.1
loads per bar for 75% capacity kN/bar 65.5 102.4 160.1 262.3 409.6

Notes:
1. Assumed beam to column application (Pin Connection).
2. Spacing based on 100mm as indicated on the table above except H16.
3. Please refer to attached PROFIS Rebar calculation reports.
4. Calculation done based on HIT REBAR METHOD. Only applicable to RE500V3.

You might also like