2. The water output of the electrolysis cell: 8 liter of alkaline water per hour
https://www.eladeanode.com/platinum-coated-titanium-electrode-for-water
- Size : 10 cm x 10 cm
- Base Material: Pure Titanium in Gr1
- Coating: Platinum
- Coating Area: Double Side and connection stem
- Platinum Coating Thickness: 2-5 micron
- Plate Type: Solid Plates
- Life spans: 15-20 years
6. Water flow speed: 8 liters per hour (through the Cathode space) + 8 liters per hour
(through the Anode space) = 16 liter/ hour total
7. Electric current (nominal value): the required current flow I(fact) = 7.6 mA ˣ 8 = 60.8 mA
Maximal electric current = 600 ma ( while using salt water)
8. Voltage between the cathode and anode during the electrolysis: 1,96 V – 20.6 V*
Were,
V – voltage
I – electric current
ρ – resistivity of electrolyte, Om x cm
L – distance between the electrodes, cm
S – area of the electrode plate, cm2
Note: *we considered that the electric resistance of semi- permeable membrane is several times less than
resistance of the electrolyte (tap water)