1
Company: JPT Page: 1
Specifier: Project: Jade Hills - RSKU
Address: Sub-Project I Pos. No.: Lifting Hook Alt -4
Phone I Fax: | Date: 25/11/2016
E-Mail:
Specifier's comments:
1 Input data
Anchor type and diameter: HIT-HY 200-R + HIT-V-F (8.8) M12
Seismic/Filling set or any suitable annular gap filling solution
Effective embedment depth: hef,opti = 73 mm (hef,limit = 95 mm)
Material: 8.8
Evaluation Service Report: ETA 12/0084
Issued I Valid: 15/4/2015 | 15/4/2020
Proof: SOFA design method + fib (07/2011) - after ETAG BOND testing
Stand-off installation: eb = 0 mm (no stand-off); t = 14 mm
Anchor plate: lx x ly x t = 150 mm x 160 mm x 14 mm; (Recommended plate thickness: not calculated
Profile: no profile
Base material: uncracked concrete, C25/30, fc = 25.00 N/mm2; h = 125 mm, Temp. short/long: 30/30 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.1
Company: JPT Page: 2
Specifier: Project: Jade Hills - RSKU
Address: Sub-Project I Pos. No.: Lifting Hook Alt -4
Phone I Fax: | Date: 25/11/2016
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.1
Company: JPT Page: 3
Specifier: Project: Jade Hills - RSKU
Address: Sub-Project I Pos. No.: Lifting Hook Alt -4
Phone I Fax: | Date: 25/11/2016
E-Mail:
5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
bN bV a Utilization bN,V [%] Status
steel 0.206 0.081 2.000 5 OK
concrete 0.781 0.452 1.500 100 OK
baN + baV <= 1
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.1
Company: JPT Page: 4
Specifier: Project: Jade Hills - RSKU
Address: Sub-Project I Pos. No.: Lifting Hook Alt -4
Phone I Fax: | Date: 25/11/2016
E-Mail:
7 Warnings
• Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading!
Input data and results must be checked for agreement with the
existing conditions and for plausibility!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• Bore hole cleaning must be performed according to instructions for use (blow 4 times with the hand pump, brush 4 times, blow again 4 times
with the hand pump).
• Characteristic bond resistances depend on short- and long-term temperatures.
• Please contact Hilti to check feasibility of HIT-V rod supply.
• The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient compressive strength (e.g. by using the HILTI Seismic/Filling set) or by other suitable means
• The compliance with current standards (e.g. EC3) is the responsibility of the user
• Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.1
Company: JPT Page: 5
Specifier: Project: Jade Hills - RSKU
Address: Sub-Project I Pos. No.: Lifting Hook Alt -4
Phone I Fax: | Date: 25/11/2016
E-Mail:
8 Installation data
Anchor plate, steel: - Anchor type and diameter: HIT-HY 200-R + HIT-V-F (8.8) M12
Profile: no profile Installation torque: 0.040 kNm
Hole diameter in the fixture: df = 14 mm Hole diameter in the base material: 14 mm
Plate thickness (input): 14 mm Hole depth in the base material: 73 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 103 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.
75 75
30
1 2
80
100
x
80
3 4
30
25 100 25
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan