You are on page 1of 6

www.hilti.com Profis Anchor 2.7.

1
Company: JPT Page: 1
Specifier: Project: Jade Hills - RSKU
Address: Sub-Project I Pos. No.: Lifting Hook Alt -4
Phone I Fax: | Date: 25/11/2016
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: HIT-HY 200-R + HIT-V-F (8.8) M12
Seismic/Filling set or any suitable annular gap filling solution
Effective embedment depth: hef,opti = 73 mm (hef,limit = 95 mm)
Material: 8.8
Evaluation Service Report: ETA 12/0084
Issued I Valid: 15/4/2015 | 15/4/2020
Proof: SOFA design method + fib (07/2011) - after ETAG BOND testing
Stand-off installation: eb = 0 mm (no stand-off); t = 14 mm
Anchor plate: lx x ly x t = 150 mm x 160 mm x 14 mm; (Recommended plate thickness: not calculated
Profile: no profile
Base material: uncracked concrete, C25/30, fc = 25.00 N/mm2; h = 125 mm, Temp. short/long: 30/30 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.1
Company: JPT Page: 2
Specifier: Project: Jade Hills - RSKU
Address: Sub-Project I Pos. No.: Lifting Hook Alt -4
Phone I Fax: | Date: 25/11/2016
E-Mail:

2 Load case/Resulting anchor forces y


Compression
Load case: Design loads
1 2
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 0.132 2.200 0.000 -2.200
2 0.132 2.200 0.000 -2.200 x
3 9.191 2.200 0.000 -2.200
4 9.191 2.200 0.000 -2.200
max. concrete compressive strain: 0.15 [‰]
max. concrete compressive stress: 4.60 [N/mm2]
resulting tension force in (x/y)=(0/-49): 18.647 [kN] 3 Tension 4
resulting compression force in (x/y)=(0/70): 9.847 [kN]

3 Tension load SOFA (fib (07/2011), section 16.2.1)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 9.191 44.667 21 OK
Combined pullout-concrete cone failure** 18.647 29.311 64 OK
Concrete Breakout Strength** 18.647 23.874 79 OK
Splitting failure** 18.647 26.916 70 OK
* anchor having the highest loading **anchor group (anchors in tension)

3.1 Steel Strength


NRk,s [kN] gM,s NRd,s [kN] NSd [kN]
67.000 1.500 44.667 9.191

3.2 Combined pullout-concrete cone failure


Ap,N [mm2] A0p,N [mm2] y A,Np
2
t Rk,ucr,25 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm]
84695 47961 1.766 15.00 219 110 56
2 0
yc t Rk,ucr [N/mm ] max t Rk,ucr [N/mm2] y g,Np y g,Np
1.020 15.30 12.47 1.000 1.000
ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np
0 1.000 49 0.693 0.853 1.000
N0Rk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NSd [kN]
42.117 43.966 1.500 29.311 18.647

3.3 Concrete Breakout Strength


Ac,N [mm2] A0c,N [mm2] y A,N ccr,N [mm] scr,N [mm]
84695 47961 1.766 110 219
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N
0 1.000 49 0.693 0.853 1.000
k1 N0Rk,c [kN] gM,c NRd,c [kN] NSd [kN]
11.000 34.304 1.500 23.874 18.647

3.4 Splitting failure


Ac,N [mm2] A0c,N [mm2] y A,N ccr,sp [mm] scr,sp [mm] y h,sp
85803 49107 1.747 111 222 1.138
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N k1
0 1.000 49 0.695 0.852 1.000 11.000
N0Rk,c [kN] gM,sp NRd,sp [kN] NSd [kN]
34.304 1.500 26.916 18.647

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.1
Company: JPT Page: 3
Specifier: Project: Jade Hills - RSKU
Address: Sub-Project I Pos. No.: Lifting Hook Alt -4
Phone I Fax: | Date: 25/11/2016
E-Mail:

4 Shear load SOFA (fib (07/2011), section 16.2.2)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 2.200 27.200 9 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 8.800 68.932 13 OK
Concrete edge failure in direction y-** 4.400 9.735 46 OK
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)


VRk,s [kN] gM,s VRd,s [kN] VSd [kN]
34.000 1.250 27.200 2.200

4.2 Pryout Strength (Concrete Breakout Strength controls)


Ac,N [mm2] A0c,N [mm2] y A,N ccr,N [mm] scr,N [mm] k4
84695 47961 1.766 110 219 2.000
ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 0.853 1.000
N0Rk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
34.304 1.500 68.932 8.800

4.3 Concrete edge failure in direction y-


lf [mm] dnom [mm] kV a b
73 12.0 2.400 0.114 0.073
c1 [mm] Ac,V [mm2] A0c,V [mm2] y A,V
56 22512 14112 1.595
y s,V y h,V y a,V ec,V [mm] y ec,V y re,V y 90°,V
1.000 1.000 1.000 0 1.000 1.000 2.000
V0Rk,c [kN] gM,c VRd,c [kN] VSd [kN]
9.154 1.500 9.735 4.400

5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
bN bV a Utilization bN,V [%] Status
steel 0.206 0.081 2.000 5 OK
concrete 0.781 0.452 1.500 100 OK
baN + baV <= 1

6 Displacements (highest loaded anchor)


Short term loading:
NSk = 6.808 [kN] dN = 0.124 [mm]
VSk = 3.259 [kN] dV = 0.163 [mm]
dNV = 0.205 [mm]
Long term loading:
NSk = 6.808 [kN] dN = 0.148 [mm]
VSk = 3.259 [kN] dV = 0.261 [mm]
dNV = 0.300 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.1
Company: JPT Page: 4
Specifier: Project: Jade Hills - RSKU
Address: Sub-Project I Pos. No.: Lifting Hook Alt -4
Phone I Fax: | Date: 25/11/2016
E-Mail:

7 Warnings
• Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading!

Input data and results must be checked for agreement with the
existing conditions and for plausibility!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• Bore hole cleaning must be performed according to instructions for use (blow 4 times with the hand pump, brush 4 times, blow again 4 times
with the hand pump).
• Characteristic bond resistances depend on short- and long-term temperatures.
• Please contact Hilti to check feasibility of HIT-V rod supply.
• The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient compressive strength (e.g. by using the HILTI Seismic/Filling set) or by other suitable means
• The compliance with current standards (e.g. EC3) is the responsibility of the user
• Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.1
Company: JPT Page: 5
Specifier: Project: Jade Hills - RSKU
Address: Sub-Project I Pos. No.: Lifting Hook Alt -4
Phone I Fax: | Date: 25/11/2016
E-Mail:

8 Installation data
Anchor plate, steel: - Anchor type and diameter: HIT-HY 200-R + HIT-V-F (8.8) M12
Profile: no profile Installation torque: 0.040 kNm
Hole diameter in the fixture: df = 14 mm Hole diameter in the base material: 14 mm
Plate thickness (input): 14 mm Hole depth in the base material: 73 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 103 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.

8.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • Dispenser including cassette and mixer
• Properly sized drill bit • Proper diameter wire brush • Seismic/Filling set
• Torque wrench
y

75 75

30
1 2

80
100

x
80

3 4
30

25 100 25

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -50 50 300 2134 156 2025
2 50 50 400 2034 156 2025
3 -50 -50 300 2134 56 2125
4 50 -50 400 2034 56 2125
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com Profis Anchor 2.7.1
Company: JPT Page: 6
Specifier: Project: Jade Hills - RSKU
Address: Sub-Project I Pos. No.: Lifting Hook Alt -4
Phone I Fax: | Date: 25/11/2016
E-Mail:

9 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

You might also like