You are on page 1of 24

DESIGN FOR S-7 4m

MINIMUM THICKNESS OF SLAB:


Perimeter of the Panel
h=
180
CORRIDOR
3m
2 ( 3.00+ 4.00 )( 1000 )
h= =77 mm ;
180
use h=77 mm
d e =51 mm

DEAD LOADS FROM NSCP TABLE 204-1

DEAD LOADS
Floor finish 0.77 kPa
Ceiling 0.38 kPa
Partition Load 0.38 kPa
Weight of Slab (h x 23.5) 1.81 kPa
TOTAL 3.34 kPa
LIVE LOADS FROM NSCP TABLE 205-1

LIVE LOADS
GROUND CORRIDOR 4.80 kPa
TOTAL 4.80 kPa

BAR DIAMETERS
Long direction 12 mm
Short direction 12 mm

DESIGN CONSTRAINTS:
Fy 414.0 MPa
f'c 21.0 MPa
β 0.85
ρmax 0.01626415
ρmin 0.00338
γconcrete 23.5 kN/cu.m.
SLAB:

¿=1.6 ( 4.8 ) =7.68 kPa


DL=1.2 ( 3.34 )=4.01 kPa
ω=7.68+ 4.01=11.69 kPa
CONSIDERING 1-meter STRIP:

ω=11.69 kN /m
La 3.00
m= = =0.75
Lb 4.00

USING COEFFICIENT METHOD:


CASE 4: from Table of coefficients for moments and shear in two-way slab panels according
to the ACI CODE

NEGATIVE MOMENTS

m comp
m 0.75 0.75 0.75
C a ,¬¿ ¿ 0.076 0.076 0.076
C b ,¬¿ ¿ 0.024 0.024 0.024

POSTIVE MOMENTS
m 0.75 0.75 0.75
C a , pos ,dl 0.043 0.043 0.043
C b , pos ,dl 0.013 0.013 0.013
C a , pos ,≪¿¿ 0.052 0.052 0.052
C b , pos ,≪¿¿ 0.016 0.016 0.016

MOMENT COEFFICIENT Ca Cb
Negative Moment 0.076 0.024
Positive Moment (DL) 0.043 0.013
Positive Moment (LL) 0.052 0.016

NEGATIVE MOMENT:
Short Direction:

M a ,¬¿=C ω L
a u a
2 2
=0.076 ( 11.69 )( 3) =7.996 kN−m ¿

Long Direction:

M b ,¬¿=C ω L
b u b
2 2
=0.024 ( 11.69 )( 4 ) = 4.489kN −m ¿

POSITIVE MOMENT:

 DEAD LOAD

Short Direction:

M a , pos , DL=Ca ω DL La2=0.043 ( 4.01 )( 3 )2=1.552 kN −m

Long Direction:

M b , pos , DL=Cb ω DL Lb2=0.013 ( 4.01 )( 4 )2=0.834 kN−m

 LIVE LOAD

Short Direction:

M a , pos ,≪¿=C a
2 2
ω¿ La =0.052 ( 7.68) ( 3 ) =3.594 kN −m ¿

Long Direction:

M b , pos ,≪¿=C b
2 2
ω¿ L b =0.016 ( 7.68) ( 4) =1.966 kN−m ¿

TOTAL POSITVE MOMENT:

Short Direction:

M a , pos ,TOTAL= M a , pos ,DL + M a , pos ,≪ ¿=1.552+3.594=5.146 kN −m ¿

Long Direction:

M b , pos ,TOTAL= M b , pos ,DL + M b , pos ,≪ ¿=0.834 +1.966=2.800 kN −m ¿

COMPUTATION OF REQUIRED REINFORCEMENT:


ALONG SHORT DIRECTION:

 AT MIDSPAN:

M U =5.146 kN −m
MU 5.146 x 10 6
Rn = 2
= 2
=2.198 MPa
ϕb d 0.90 ( 1000 )( 51 )

2 Rn
ρactual =
0.85 f ' c
fy [ √
1− 1− '
0.85 f c
= ]
0.85(21)
414
1− 1−
2(2.198)
[ √
0.85(414)]= 0.00568

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρactual

A s=ρbd=0.00568 ( 1000 ) (51 )=289.68 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=289.68 )
S=390.42mm

USE:

S =150 mm

 AT THE CONTINUOUS EDGE:

M U =7.996 kN −m

MU 7.996 x 10 6
Rn = 2
= 2
=3.416 MPa
ϕb d 0.90 ( 1000 )( 51 )

2 Rn
ρactual =
0.85 f ' c
fy [ √
1− 1− '
0.85 f c
= ]
0.85(21)
414
1− 1−
2(3.416)
[ √
0.85(414)]= 0.00924

1.4 1.4
ρmin = = =0.00338
f y 414
Use: ρactual

A s=ρbd=0.00924 ( 1000 ) ( 51 )=471.24 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=471.24 )
S=240 mm

USE:

S = 150 mm

 AT THE DISCONTINUOUS EDGE:

M U =2.573 kN −m

MU 2.573 x 10 6
Rn = 2
= 2
=1.099 MPa
ϕb d 0.90 ( 1000 )( 51 )

2 Rn
ρactual =
0.85 f ' c
fy [ √
1− 1− '
0.85 f c
= ]
0.85(21)
414
1− 1−
2(1.099)
[ √ ]
0.85(414)
= 0.00274

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρmin

A s=ρbd=0.00338 ( 1000 ) (51 )=172.38 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=172.38 )
S=656.09 mm

USE:

S = 150 mm

ALONG LONG DIRECTION:


 AT MIDSPAN:

M U =2.800 kN −m

MU 2.800 x 10 6
Rn = 2
= 2
=2.045 MPa
ϕb d 0.90 ( 1000 )( 39 )

2 Rn
ρactual =
0.85 f ' c
fy [ √
1− 1− '
0.85 f c
= ]
0.85(21)
414
1− 1−
2(2.045)
[ √
0.85(414)]= 0.00526

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρactual

A s=ρbd=0.00526 ( 1000 ) ( 39 )=205.14 mm 2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=205.14 )
S=551.32mm

USE:

S = 150 mm
 AT THE CONTINUOUS EDGE:

M U =4.489 kN−m

MU 4.48910 6
Rn = 2
= =3.279 MPa
ϕb d 0.90 ( 1000 )( 39 )2

ρactual =
0.85 f ' c
fy [ √
1− 1−
2 Rn
'
0.85 f c
= ]
0.85(21)
414
1− 1−
2(3.279)
[ √
0.85( 414)]= 0.00882

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρactual

A s=ρbd=0.00882 ( 1000 )( 39 )=343.98 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=343.98 )
S=328.79mm

USE:

S = 150 mm

 AT THE DISCONTINUOUS EDGE:

M U =1.400 kN −m

MU 1.400 x 10 6
Rn = = =1.023 MPa
ϕb d 2 0.90 ( 1000 )( 39 )2
ρactual =
fy [ √
0.85 f ' c
1− 1−
2 Rn
]
'
0.85 f c
=
0.85(21)
414[ √1− 1−
2(1.023)
0.85(414)]= 0.00255

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρmin

A s=ρbd=0.00338 ( 1000 ) ( 39 )=131.82 mm2

For the spacing of reinforcement:

2
1000 π (12)
S ( 4 )
=131.82

S=857.97 mm

USE :

S = 150 mm
DESIGN FOR S-8 4m
MINIMUM THICKNESS OF SLAB:
Perimeter of the Panel
h=
180
CORRIDOR
3m
2 ( 3.00+ 4.00 )( 1000 )
h= =77 mm ;
180
use h=77 mm
d e =51 mm

DEAD LOADS FROM NSCP TABLE 204-1

DEAD LOADS
Floor finish 0.77 kPa
Ceiling 0.38 kPa
Partition Load 0.38 kPa
Weight of Slab (h x 23.5) 1.81 kPa
TOTAL 3.34 kPa
LIVE LOADS FROM NSCP TABLE 205-1

LIVE LOADS
GROUND CORRIDOR 4.80 kPa
TOTAL 4.80 kPa

BAR DIAMETERS
Long direction 12 mm
Short direction 12 mm

DESIGN CONSTRAINTS:
Fy 414.0 MPa
f'c 21.0 MPa
β 0.85
ρmax 0.01626415
ρmin 0.00338
γconcrete 23.5 kN/cu.m.

SLAB:

¿=1.6 ( 4.8 ) =7.68 kPa


DL=1.2 ( 3.34 )=4.01 kPa
ω=7.68+ 4.01=11.69 kPa
CONSIDERING 1-meter STRIP:

ω=11.69 kN /m
La 3.00
m= = =0.75
Lb 4.00

USING COEFFICIENT METHOD:


CASE 6: from Table of coefficients for moments and shear in two-way slab panels according
to the ACI CODE

NEGATIVE MOMENTS

m comp
m 0.75 0.75 0.75
C a ,¬¿ ¿ 0.088 0.088 0.088
C b ,¬¿ ¿ 0.088 0.088 0.088

POSTIVE MOMENTS
m 0.75 0.75 0.75
C a , pos ,dl 0.048 0.048 0.048
C b , pos ,dl 0.012 0.012 0.012
C a , pos ,≪¿¿ 0.055 0.055 0.055
C b , pos ,≪¿¿ 0.016 0.016 0.016

MOMENT COEFFICIENT Ca Cb
Negative Moment 0.088 0.088
Positive Moment (DL) 0.048 0.012
Positive Moment (LL) 0.055 0.016

NEGATIVE MOMENT:

Short Direction:

M a ,¬¿=C ω L
a u a
2 2
=0.088 ( 11.69 )( 3) =9.258 kN−m ¿

Long Direction:

M b ,¬¿=C ω L
b u b
2 2
=0.088 ( 11.69 )( 4) =16.460 kN−m ¿

POSITIVE MOMENT:

 DEAD LOAD

Short Direction:

M a , pos , DL=Ca ω DL La2=0.048 ( 4.01 )( 3 )2=1.732 kN −m

Long Direction:

M b , pos , DL=Cb ω DL Lb2=0.012 ( 4.01 ) ( 4 )2=0.770 kN −m

 LIVE LOAD

Short Direction:

M a , pos ,≪¿=C a
2 2
ω¿ La =0.055 ( 7.68) ( 3 ) =3.802 kN −m ¿

Long Direction:

M b , pos ,≪¿=C b
2 2
ω¿ L b =0.016 ( 7.68) ( 4) =1.966 kN−m ¿

TOTAL POSITVE MOMENT:

Short Direction:

M a , pos ,TOTAL= M a , pos ,DL + M a , pos ,≪ ¿=1.732+3.802=5.534 kN−m ¿

Long Direction:

M b , pos ,TOTAL= M b , pos ,DL + M b , pos ,≪ ¿=0.770+1.966=2.736 kN −m ¿

COMPUTATION OF REQUIRED REINFORCEMENT:


ALONG SHORT DIRECTION:

 AT MIDSPAN:

M U =5.534 kN−m

MU 5.534 x 10 6
Rn = 2
= =2.364 MPa
ϕb d 0.90 ( 1000 )( 51 )2

ρactual =
0.85 f ' c
fy [ √
1− 1−
2 Rn
'
0.85 f c
= ]
0.85(21)
414
1− 1−
2(2.364)
[ √
0.85(414)]= 0.00615

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρactual

A s=ρbd=0.00615 ( 1000 ) (51 )=313.65 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=313.65 )
S=360.58mm

USE:

S =150 mm

 AT THE CONTINUOUS EDGE:

M U =9.258 kN −m

MU 9.258 x 10 6
Rn = 2
= =3.955 MPa
ϕb d 0.90 ( 1000 )( 51 )2
2 Rn
ρactual =
0.85 f ' c
fy [ √
1− 1− '
0.85 f c ]
=
0.85(21)
414 [ √
1− 1−
2(3.955)
0.85(414) ]
= 0.0109

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρactual

A s=ρbd=0.0109 ( 1000 ) (51 )=557.99 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4 )
=557.99

S=202.69mm

USE:

S = 150 mm

 AT THE DISCONTINUOUS EDGE:

M U =2.767 kN −m

MU 2.767 x 10 6
Rn = = =1.182 MPa
ϕb d 2 0.90 ( 1000 )( 51 )2

ρactual =
fy [ √
0.85 f ' c
1− 1−
2 Rn
]
'
0.85 f c
=
0.85(21)
414[ √1− 1−
2(1.182)
0.85(414)]= 0.00296

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρmin
A s=ρbd=0.00338 ( 1000 ) (51 )=172.38 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=172.38 )
S=656.09 mm

USE:

S = 150 mm

ALONG LONG DIRECTION:


 AT MIDSPAN:

M U =2.736 kN −m

MU 2.736 x 106
Rn = 2
= 2
=1.999 MPa
ϕb d 0.90 ( 1000 )( 39 )

2 Rn
ρactual =
0.85 f ' c
fy [ √
1− 1− '
0.85 f c
= ]
0.85(21)
414
1− 1−
2(1.999)
[ √
0.85(414)]= 0.00513

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρactual

A s=ρbd=0.00513 ( 1000 ) ( 39 )=200.20 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=200.20 )
S=564.92mm
USE:

S = 150 mm

 AT THE CONTINUOUS EDGE:

M U =16.460 kN −m

MU 16.460 x 10 6
Rn = 2
= =12.024 MPa
ϕb d 0.90 ( 1000 )( 39 )2

ρactual =
0.85 f ' c
fy [ √
1− 1−
2 Rn
'
0.85 f c
= ]
0.85(21)
414
1− 1−
2(12.024)
[ √ ]
0.85( 414)
= 0.00882

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρactual

A s=ρbd=0.00882 ( 1000 )( 39 )=343.98 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=343.98 )
S=328.79mm

USE:

S = 150 mm
 AT THE DISCONTINUOUS EDGE:

M U =1.368 kN −m

MU 1.368 x 10 6
Rn = 2
= =0.999 MPa
ϕb d 0.90 ( 1000 )( 39 )2

ρactual =
0.85 f ' c
fy [ √
1− 1−
2 Rn
'
0.85 f c
= ]
0.85(21)
414
1− 1−
2(0.999)
[ √ ]
0.85(414)
= 0.00249

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρmin

A s=ρbd=0.00338 ( 1000 ) ( 39 )=131.82 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=131.82 )
S=857.97 mm

USE :

S = 150 mm
DESIGN FOR S-9 4m
MINIMUM THICKNESS OF SLAB:
Perimeter of the Panel
h=
180
CORRIDOR
3m
2 ( 3.00+ 4.00 )( 1000 )
h= =77 mm ;
180
use h=77 mm
d e =51 mm

DEAD LOADS FROM NSCP TABLE 204-1

DEAD LOADS
Floor finish 0.77 kPa
Ceiling 0.38 kPa
Partition Load 0.38 kPa
Weight of Slab (h x 23.5) 1.81 kPa
TOTAL 3.34 kPa
LIVE LOADS FROM NSCP TABLE 205-1

LIVE LOADS
GROUND CORRIDOR 4.80 kPa
TOTAL 4.80 kPa

BAR DIAMETERS
Long direction 12 mm
Short direction 12 mm

DESIGN CONSTRAINTS:
Fy 414.0 MPa
f'c 21.0 MPa
β 0.85
ρmax 0.01626415
ρmin 0.00338
γconcrete 23.5 kN/cu.m.

SLAB:

¿=1.6 ( 4.8 ) =7.68 kPa


DL=1.2 ( 3.34 )=4.01 kPa
ω=7.68+ 4.01=11.69 kPa
CONSIDERING 1-meter STRIP:

ω=11.69 kN /m
La 3.00
m= = =0.75
Lb 4.00

USING COEFFICIENT METHOD:


CASE 1: from Table of coefficients for moments and shear in two-way slab panels according
to the ACI CODE

NEGATIVE MOMENTS

m comp
m 0.75 0.75 0.75
C a ,¬¿ ¿ 0.000 0.000 0.000
C b ,¬¿ ¿ 0.000 0.000 0.000

POSTIVE MOMENTS
m 0.75 0.75 0.75
C a , pos ,dl 0.061 0.061 0.061
C b , pos ,dl 0.019 0.019 0.019
C a , pos ,≪¿¿ 0.061 0.061 0.061
C b , pos ,≪¿¿ 0.019 0.019 0.019

MOMENT COEFFICIENT Ca Cb
Negative Moment 0.000 0.000
Positive Moment (DL) 0.061 0.019
Positive Moment (LL) 0.061 0.019

NEGATIVE MOMENT:

Short Direction:

M a ,¬¿=C ω L
a u a
2 2
=0.000 ( 11.69 )( 3 ) =0.000 kN−m ¿

Long Direction:

M b ,¬¿=C ω L
b u b
2 2
=0.000 ( 11.69 )( 4) =0.000 kN −m ¿

POSITIVE MOMENT:

 DEAD LOAD

Short Direction:

M a , pos , DL=Ca ω DL La2=0.061 ( 4.01 ) ( 3 )2=2.201 kN −m

Long Direction:

M b , pos , DL=Cb ω DL Lb2=0.019 ( 4.01 )( 4 )2=1.2 19 kN−m

 LIVE LOAD

Short Direction:

M a , pos ,≪¿=C a
2 2
ω¿ La =0.061 ( 7.68) ( 3 ) = 4.216kN −m ¿

Long Direction:

M b , pos ,≪¿=C b
2 2
ω¿ L b =0.019 ( 7.68) ( 4 ) =2.335 kN−m ¿

TOTAL POSITVE MOMENT:

Short Direction:

M a , pos ,TOTAL= M a , pos ,DL + M a , pos ,≪ ¿=2.201+4.216=6.417 kN −m ¿


Long Direction:

M b , pos ,TOTAL= M b , pos ,DL + M b , pos ,≪ ¿=1.219+2.335=3.554 kN −m ¿

COMPUTATION OF REQUIRED REINFORCEMENT:


ALONG SHORT DIRECTION:

 AT MIDSPAN:

M U =6.417 kN −m

MU 6.417 x 10 6
Rn = 2
= =2.741 MPa
ϕb d 0.90 ( 1000 )( 51 )2

ρactual =
0.85 f ' c
fy [ √
1− 1−
2 Rn
'
0.85 f c
=
414 ]
0.85(21)
1− 1−
2(2.741)
0.85(414) [ √ ]
= 0.00723

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρactual

A s=ρbd=0.00723 ( 1000 ) (51 )=368.58 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (
4
=368.58 )
S=306.84 mm

USE:

S =150 mm

 AT THE CONTINUOUS EDGE:


M U =0.000 kN −m

MU 0.000 x 10 6
Rn = 2
= 2
=0.000 MPa
ϕb d 0.90 ( 1000 )( 51 )

2 Rn
ρactual =
0.85 f ' c
fy [ √
1− 1− '
0.85 f c
= ]
0.85(21)
414
1− 1−
2(0.000)
[ √
0.85( 414)]= 0.000

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρmin

A s=ρbd=0.00338 ( 1000 ) (51 )=172.38 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=172.38 )
S=656.09 mm

USE:

S = 150 mm

 AT THE DISCONTINUOUS EDGE:

M U =3.209 kN −m

MU 3.209 x 10 6
Rn = 2
= =1.371 MPa
ϕb d 0.90 ( 1000 )( 51 )2

ρactual =
0.85 f ' c
fy [ √
1− 1−
2 Rn
'
0.85 f c
= ]
0.85(21)
414
1− 1−
2(1.371)
[ √
0.85(414) ]
= 0.00345
1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρactual

A s=ρbd=0.00345 ( 1000 ) (51 )=175.88 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=175.88 )
S=643.04 mm

USE:

S = 150 mm

ALONG LONG DIRECTION:


 AT MIDSPAN:

M U =3.554 kN−m

MU 3.554 x 106
Rn = 2
= =2.596 MPa
ϕb d 0.90 ( 1000 )( 39 )2

ρactual =
0.85 f ' c
fy [ √
1− 1−
2 Rn
'
0.85 f c
= ]
0.85(21)
414
1− 1−
2(2.596)
[ √
0.85( 414)]= 0.00681

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρactual

A s=ρbd=0.00681 ( 1000 )( 39 )=265.54 mm2

For the spacing of reinforcement:


2
1000 π (12)
S (4
=265.54 )
S=425.91 mm

USE:

S = 150 mm

 AT THE CONTINUOUS EDGE:

M U =0.000 kN −m

MU 0.000 x 106
Rn = 2
= 2
=0.000 MPa
ϕb d 0.90 ( 1000 )( 39 )

2 Rn
ρactual =
0.85 f ' c
fy [ √
1− 1− '
0.85 f c
= ]
0.85(21)
414
1− 1−
2(0.000)
[ √
0.85( 414)]= 0.000

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρmin

A s=ρbd=0.00338 ( 1000 ) ( 39 )=131.82 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=131.82 )
S=857.97 mm
USE:

S = 150 mm

 AT THE DISCONTINUOUS EDGE:

M U =1.777 kN −m

MU 1.777 x 10 6
Rn = 2
= 2
=1.298 MPa
ϕb d 0.90 ( 1000 )( 39 )

2 Rn
ρactual =
0.85 f ' c
fy [ √
1− 1− '
0.85 f c
= ]
0.85(21)
414
1− 1−
2(1.298)
[ √
0.85(414)]= 0.00326

1.4 1.4
ρmin = = =0.00338
f y 414

Use: ρmin

A s=ρbd=0.00338 ( 1000 ) ( 39 )=131.82 mm2

For the spacing of reinforcement:

2
1000 π (12)
S (4
=131.82 )
S=857.97 mm

USE :

S = 150 mm