Professional Documents
Culture Documents
Ball Mill 1
Tag No description points to check ok correction action comment
check motor for earthing connection
check motor for heating , vibration , noise , cable , cleaning
Belt check LCP for cable , damage , cleaning
481.BC640
conveyor check speed motion sensor for cable , looseness , cleaning
check safety switch for cable , damage , cleaning
check safety pull rope switches for cable , damage , cleaning
check motor for earthing connection
check motor for heating , vibration , noise , cable , cleaning
Belt check LCP for cable , damage , cleaning
242.BC560
conveyor check speed motion sensor for cable , looseness , cleaning
check safety switch for cable , damage , cleaning
check safety pull rope switches for cable , damage , cleaning
check motor for earthing connection
check motor for heating , vibration , noise , cable , cleaning
Belt check LCP for cable , damage , cleaning
242.BC540
conveyor check speed motion sensor for cable , looseness , cleaning
check safety switch for cable , damage , cleaning
check safety pull rope switches for cable , damage , cleaning
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
242.BF510 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
242.FN512 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check motor for earthing connection
Rotary air
242.RF511 check motor for heating , vibration , noise , cable , cleaning
lock
check LCP for cable , damage , cleaning
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
242.BF550 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
500A1 1
General inspection for Cement Grinding
Ball Mill 1
Tag No description points to check ok correction action comment
check motor for earthing connection
242.FN552 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check motor for earthing connection
Rotary air
242.RF551 check motor for heating , vibration , noise , cable , cleaning
lock
check LCP for cable , damage , cleaning
check level transmitter ( 511.BI100N01 ) for looseness ,
cleaning , cables , cover
511.BI100 Clinker silo
check level switch ( 511.BI100D01 ) for looseness , cleaning ,
cables , cover
check level transmitter ( 511.BI200N01 ) for looseness ,
cleaning , cables , cover
511.BI200 Gypsum silo
check level switch ( 511.BI200D01 ) for looseness , cleaning ,
cables , cover
check level transmitter ( 511.BI300N01 ) for looseness ,
cleaning , cables , cover
511.BI300 Additive silo
check level switch ( 511.BI300D01 ) for looseness , cleaning ,
cables , cover
check LCP for cable , damage , cleaning
check weigh feeder junction box A40 for cables,cable
glands,damage,cleaning
check load cells for cable, damage,cleaning,looseness
Weigh
511.WF150 check lubrication pump for cable,cleaning,grease level
feeder
check chain conveyor motor for
earthing,cleaning,looseness,noise,vibration,heating
check scrabar motor for
earthing,cleaning,looseness,noise,vibration,heating
check LCP for cable , damage , cleaning
check weigh feeder junction box A40 for cables,cable
Weigh glands,damage,cleaning
511.WF250
feeder check speed motion sensor for cable , looseness , cleaning
check conveyor motor for
earthing,cleaning,looseness,noise,vibration,heating
500A1 2
General inspection for Cement Grinding
Ball Mill 1
Tag No description points to check ok correction action comment
check LCP for cable , damage , cleaning
check weigh feeder junction box A40 for cables,cable
Weigh
511.WF350 glands,damage,cleaning
feeder
check conveyor motor for
earthing,cleaning,looseness,noise,vibration,heating
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
511.BF660 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
511.FN662 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check motor for earthing connection
Rotary air
511.RF661 check motor for heating , vibration , noise , cable , cleaning
lock
check LCP for cable , damage , cleaning
check motor for earthing connection
check motor for heating , vibration , noise , cable , cleaning
Belt check LCP for cable , damage , cleaning
511.BC600
conveyor check speed motion sensor for cable , looseness , cleaning
check safety switch for cable , damage , cleaning
check safety pull rope switches for cable , damage , cleaning
Earthing check earthing bar & earthing points for
System fixed,connection,damage
lighting & check for damage, cleaning, cable, in case some rechargeable
miscellaneo Sockets check if it is charging
us for
checking check the fire extinguisher if available in all floors
during the Fire fighting
inspection in Warning
the sector system
check for damage, cleaning, cables
Telephone in case the telephone available check if working
Electrical check electrical hoist for if energized, the LCP not damage,
Hoist cables, good situation
inspected Date
next inspection
inspected by
500A1 3
General inspection for Cement Grinding
Ball Mill 2
Tag No description points to check ok correction action comment
check motor for earthing connection
check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
Belt
242.BC580 check speed motion sensor for cable , looseness , cleaning
conveyor
check safety switch for cable , damage , cleaning
check safety pull rope switches for cable , damage , cleaning
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
242.BF570 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
242.FN572 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check motor for earthing connection
Rotary air
242.RF571 check motor for heating , vibration , noise , cable , cleaning
lock
check LCP for cable , damage , cleaning
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
242.BF680 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
242.FN682 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check motor for earthing connection
Rotary air
242.RF681 check motor for heating , vibration , noise , cable , cleaning
lock
check LCP for cable , damage , cleaning
check level transmitter ( 511.BI100N01 ) for looseness ,
cleaning , cables , cover
512.BI100 Clinker silo
check level switch ( 511.BI100D01 ) for looseness , cleaning ,
cables , cover
500A2 4
General inspection for Cement Grinding
Ball Mill 2
check level transmitter ( 511.BI200N01 ) for looseness ,
cleaning , cables , cover
512.BI200 Gypsum silo
check level switch ( 511.BI200D01 ) for looseness , cleaning ,
cables , cover
check level transmitter ( 511.BI300N01 ) for looseness ,
cleaning , cables , cover
512.BI300 Additive silo
check level switch ( 511.BI300D01 ) for looseness , cleaning ,
cables , cover
check LCP for cable , damage , cleaning
check weigh feeder junction box A40 for cables,cable
glands,damage,cleaning
check load cells for cable, damage,cleaning,looseness
Weigh
512.WF150 check lubrication pump for cable,cleaning,grease level
feeder
check chain conveyor motor for
earthing,cleaning,looseness,noise,vibration,heating
check scrabar motor for
earthing,cleaning,looseness,noise,vibration,heating
check LCP for cable , damage , cleaning
check weigh feeder junction box A40 for cables,cable
Weigh glands,damage,cleaning
512.WF250
feeder check speed motion sensor for cable , looseness , cleaning
check conveyor motor for
earthing,cleaning,looseness,noise,vibration,heating
check LCP for cable , damage , cleaning
check weigh feeder junction box A40 for cables,cable
Weigh
512.WF350 glands,damage,cleaning
feeder
check conveyor motor for
earthing,cleaning,looseness,noise,vibration,heating
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
512.BF660 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
512.FN662 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
500A2 5
General inspection for Cement Grinding
Ball Mill 2
check motor for earthing connection
Rotary air
512.RF661 check motor for heating , vibration , noise , cable , cleaning
lock
check LCP for cable , damage , cleaning
check motor for earthing connection
check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
Belt
512.BC600 check speed motion sensor for cable , looseness , cleaning
conveyor
check safety switch for cable , damage , cleaning
check safety pull rope switches for cable , damage , cleaning
inspected Date
next inspection
inspected by
500A2 6
General inspection for Cement Grinding
Ball Mill 1
Tag No description points to check ok correction action comment
Throttle check motor for earthing connection
531.TV520
valve check motor for cable , cleaning & looseness
check motor for earthing connection
check motor for heating , vibration , noise , cable , cleaning
531.FN530 Fan
check LCP for cable , damage , cleaning
check safety switch for cable , damage , cleaning
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
531.BF500 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
531.SC501 Screw check motor for heating , vibration , noise , cable , cleaning
conveyor check LCP for cable , damage , cleaning
check speed sensor for cleaning, cable, damage & looseness
check motor for earthing connection
Rotary air check motor for heating , vibration , noise , cable , cleaning
531.RF502
lock check LCP for cable , damage , cleaning
check speed sensor for cleaning, cable, damage & looseness
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
541.FN121 fan /
541.AS120 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
check solenoid valves for damage , cleaning & looseness
541.DG122 dividing check all air hoses for leakage, damage
gate
check all Proximity Sensors for cleaning, damage, cable, looseness
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
531.BF240 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
531.RF241 Rotary air
lock check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check motor for earthing connection
531.FN242 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
500B1 7
General inspection for Cement Grinding
Ball Mill 1
Tag No description points to check ok correction action comment
check motor for earthing connection
check motor for heating , vibration , noise , cable , cleaning
Bucket
531.BE220M01
elevator check LCP for cable , damage , cleaning
check speed motion sensor for cable , looseness , cleaning
check safety switch for cable , damage , cleaning
check motor for earthing connection
Bucket check motor for heating , vibration , noise , cable , cleaning
531.BE220M02
elevator check LCP for cable , damage , cleaning
check safety switch for cable , damage , cleaning
Motion check both motion detectors with junction box for cleaning ,
531BE220D01S41 Detector cables , looseness
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
531.FN231 fan /
531.AS230 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
531.BF500N01T01 Temp.Trans check transmitter for cleaning, damage, cable, looseness
mitter
531BM100N04P01 pressure.Tr
check transmitter for cleaning, damage, cable, looseness,
ansmitter display & hose connection
500B1 8
General inspection for Cement Grinding
Ball Mill 1
Tag No description points to check ok correction action comment
check motor for earthing connection
Rotary air check motor for heating , vibration , noise , cable , cleaning
531.RF321
lock check LCP for cable , damage , cleaning
check speed sensor for cleaning, cable, damage & looseness
check motor for earthing connection
Rotary air check motor for heating , vibration , noise , cable , cleaning
531.RF331
lock check LCP for cable , damage , cleaning
check speed sensor for cleaning, cable, damage & looseness
check motor for earthing connection
Rotary air check motor for heating , vibration , noise , cable , cleaning
531.RF341 lock check LCP for cable , damage , cleaning
check speed sensor for cleaning, cable, damage & looseness
500B1 9
General inspection for Cement Grinding
Ball Mill 1
Tag No description points to check ok correction action comment
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
531.BF360 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
531.RF502 Rotary air
lock check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
531BF360N01T01 Temp.Trans check transmitter for cleaning, damage, cable, looseness
mitter
Throttle check motor for earthing connection
531.TV370
valve check motor for cable , cleaning & looseness
check motor for earthing connection
531.FN380 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
531SR300N03P01 pressure.Tr check transmitter for cleaning, damage, cable, looseness,
ansmitter display & hose connection
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
541.BF140 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
Rotary air
541.RF141 lock check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check motor for earthing connection
541.FN142 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check all motors for heating , vibration , noise , cable , cleaning
531.GR197 Grinding aid
sys check LCP for cable , damage , cleaning
check all instruments for cable , damage , cleaning
531BM100N02P01 pressure.Tr
check transmitter for cleaning, damage, cable, looseness,
ansmitter display & hose connection
Flow check Flow Measurement for cable , damage , cleaning & if any
531FM420 Measurement
alarm
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
531.FN411 fan /
531.AS410 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
500B1 10
General inspection for Cement Grinding
Ball Mill 1
Tag No description points to check ok correction action comment
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
531.FN211 fan /
531.AS210 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
Oil check all motors for heating , vibration , noise , cable , cleaning
531.LQ110 lubrication check all junction boxes for cable , damage , cleaning
unit check all instruments for cable , damage , cleaning
Oil check all motors for heating , vibration , noise , cable , cleaning
531.LQ120 lubrication check all junction boxes for cable , damage , cleaning
unit check all instruments for cable , damage , cleaning
Oil check all motors for heating , vibration , noise , cable , cleaning
531.LQ145 lubrication check all junction boxes for cable , damage , cleaning
unit check all instruments for cable , damage , cleaning
check all motors for heating , vibration , noise , cable , cleaning
Water
531.WI130
injection check all junction boxes for cable , damage , cleaning
check all instruments for cable , damage , cleaning
531BM100N05T01 Temp.Trans check transmitter for cleaning, damage, cable, looseness
mitter
check the motor for heating , vibration , noise , cable , cleaning , any
spark in carbon brushes & all sensors with junction boxes
check LCP for cable , damage , cleaning
Cement mill
531.MD140M01 main motor check motor for earthing connection
check the liquid rheostat ( pump & panel ) for cable , any
alarm
check capacitor bank for cable , cleaning, any alarm
check motor for earthing connection
check motor for heating , vibration , noise , cable , cleaning
531.AD147M01 Aux. Drive
check LCP for cable , damage , cleaning
check the limit switches for cable, cleaning, damage
Earthing check earthing bar & earthing points for
System fixed,connection,damage
lighting & check for damage, cleaning, cable, in case some rechargeable
Sockets check if it is charging
miscellaneous for
checking during check the fire extinguisher if available in all floors
the inspection in Fire fighting
the sector Warning
system
check for damage, cleaning, cables
Telephone in case the telephone available check if working
Electrical check electrical hoist for if energized, the LCP not damage,
Hoist cables, good situation
500B1 11
General inspection for Cement Grinding
Ball Mill 2
Tag No description points to check ok correction action comment
Throttle check motor for earthing connection
532.TV520
valve check motor for cable , cleaning & looseness
check motor for earthing connection
check motor for heating , vibration , noise , cable , cleaning
532.FN530 Fan
check LCP for cable , damage , cleaning
check safety switch for cable , damage , cleaning
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
532.BF500 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
Screw check motor for heating , vibration , noise , cable , cleaning
532.SC501 conveyor check LCP for cable , damage , cleaning
check speed sensor for cleaning, cable, damage & looseness
check motor for earthing connection
532.RF502 Rotary air check motor for heating , vibration , noise , cable , cleaning
lock check LCP for cable , damage , cleaning
check speed sensor for cleaning, cable, damage & looseness
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
542.FN121 fan /
542.AS120 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
check solenoid valves for damage , cleaning & looseness
542.DG122 dividing check all air hoses for leakage, damage
gate
check all Proximity Sensors for cleaning, damage, cable, looseness
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
532.BF240 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
Rotary air
532.RF241 lock check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check motor for earthing connection
532.FN242 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check motor for earthing connection
check motor for heating , vibration , noise , cable , cleaning
Bucket
532.BE220M01
elevator check LCP for cable , damage , cleaning
check speed motion sensor for cable , looseness , cleaning
check safety switch for cable , damage , cleaning
500B2 12
General inspection for Cement Grinding
Ball Mill 2
Tag No description points to check ok correction action comment
check motor for earthing connection
Bucket check motor for heating , vibration , noise , cable , cleaning
532.BE220M02
elevator check LCP for cable , damage , cleaning
check safety switch for cable , damage , cleaning
532BE220D01S41 Motion check both motion detectors with junction box for cleaning ,
Detector cables , looseness
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
532.FN231 fan /
532.AS230 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
532.BF500N01T01 Temp.Trans check transmitter for cleaning, damage, cable, looseness
mitter
532BM100N04P01 pressure.Tr
check transmitter for cleaning, damage, cable, looseness,
ansmitter display & hose connection
500B2 13
General inspection for Cement Grinding
Ball Mill 2
Tag No description points to check ok correction action comment
check motor for earthing connection
532.RF331 Rotary air check motor for heating , vibration , noise , cable , cleaning
lock check LCP for cable , damage , cleaning
check speed sensor for cleaning, cable, damage & looseness
check motor for earthing connection
532.RF341 Rotary air check motor for heating , vibration , noise , cable , cleaning
lock check LCP for cable , damage , cleaning
check speed sensor for cleaning, cable, damage & looseness
532.FN350 Separator check motor for heating , vibration , noise , cable , cleaning
Fan check safety switch for cable , damage , cleaning
check LCP for cable , damage , cleaning
500B2 14
General inspection for Cement Grinding
Ball Mill 2
Tag No description points to check ok correction action comment
Louver check motor for earthing connection
532.LD345
damper check motor for cable , cleaning & looseness
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
532.BF360 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
Rotary air
532.RF502 check motor for heating , vibration , noise , cable , cleaning
lock
check LCP for cable , damage , cleaning
532BF360N01T01 Temp.Trans check transmitter for cleaning, damage, cable, looseness
mitter
Throttle check motor for earthing connection
532.TV370
valve check motor for cable , cleaning & looseness
check motor for earthing connection
532.FN380 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check transmitter for cleaning, damage, cable, looseness,
532SR300N03P01 pressure.Tr display & hose connection
ansmitter
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
542.BF140 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
Rotary air
542.RF141 check motor for heating , vibration , noise , cable , cleaning
lock
check LCP for cable , damage , cleaning
check motor for earthing connection
542.FN142 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check all motors for heating , vibration , noise , cable , cleaning
Grinding aid
532.GR197 check LCP for cable , damage , cleaning
sys
check all instruments for cable , damage , cleaning
532.BM100N02P01 pressure.Tr
check transmitter for cleaning, damage, cable, looseness,
ansmitter display & hose connection
Flow check Flow Measurement for cable , damage , cleaning & if any
532.FM420 Measurement
alarm
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
532.FN411 fan /
532.AS410 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
500B2 15
General inspection for Cement Grinding
Ball Mill 2
Tag No description points to check ok correction action comment
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
532.FN211 fan /
532.AS210 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
Oil check all motors for heating , vibration , noise , cable , cleaning
532.LQ110 lubrication check all junction boxes for cable , damage , cleaning
unit check all instruments for cable , damage , cleaning
Oil check all motors for heating , vibration , noise , cable , cleaning
532.LQ120 lubrication check all junction boxes for cable , damage , cleaning
unit check all instruments for cable , damage , cleaning
Oil check all motors for heating , vibration , noise , cable , cleaning
532.LQ145 lubrication check all junction boxes for cable , damage , cleaning
unit check all instruments for cable , damage , cleaning
check all motors for heating , vibration , noise , cable , cleaning
Water
532.WI130 injection check all junction boxes for cable , damage , cleaning
check all instruments for cable , damage , cleaning
532.BM100N05T01 Temp.Trans check transmitter for cleaning, damage, cable, looseness
mitter
check the motor for heating , vibration , noise , cable , cleaning , any
spark in carbon brushes & all sensors with junction boxes
check LCP for cable , damage , cleaning
Cement mill check motor for earthing connection
532.MD140M01
main motor
check the liquid rheostat ( pump & panel ) for cable , any
alarm
check capacitor bank for cable , cleaning, any alarm
check motor for earthing connection
check motor for heating , vibration , noise , cable , cleaning
532.AD147M01 Aux. Drive
check LCP for cable , damage , cleaning
check the limit switches for cable, cleaning, damage
Earthing check earthing bar & earthing points for
System fixed,connection,damage
lighting & check for damage, cleaning, cable, in case some rechargeable
Sockets check if it is charging
miscellaneous for
checking during check the fire extinguisher if available in all floors
the inspection in Fire fighting
the sector Warning
system
check for damage, cleaning, cables
Telephone in case the telephone available check if working
Electrical check electrical hoist for if energized, the LCP not damage,
Hoist cables, good situation
500B2 16
Transport between cement mills to cement silo
500C 17
Transport between cement mills to cement silo
541BE210D07T41 Coupling check Coupling Temperature with junction box for cleaning ,
Temperature cables , looseness
541BE210D06L41 Level switch check Level switch for cleaning , cables , looseness
541BE210D02Z41/D03Z41
/D04Z41/D05Z41 Drift Trip checkDrift Trip switch for cleaning , cables , looseness
check motor for earthing connection
Bucket check motor for heating , vibration , noise , cable , cleaning
542.BE210M01 elevator
main motor check LCP for cable , damage , cleaning
check safety switch for cable , damage , cleaning
check motor for earthing connection
Bucket check motor for heating , vibration , noise , cable , cleaning
542.BE210M02 elevator
AUX. motor check LCP for cable , damage , cleaning
check safety switch for cable , damage , cleaning
542BE210D01S41/ Motion check both motion detectors with junction box for cleaning ,
D08S41 Detector cables , looseness
542BE210D07T41 Coupling check Coupling Temperature with junction box for cleaning ,
Temperature cables , looseness
542BE210D06L41 Level switch check Level switch for cleaning , cables , looseness
542BE210D02Z41/D03Z41
/D04Z41/D05Z41 Drift Trip checkDrift Trip switch for cleaning , cables , looseness
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
541.FN221 fan /
541.AS220 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
542.FN221 fan /
542.AS220 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
500C 18
Transport between cement mills to cement silo
500C 19
Transport between cement silos to Packing plant
Tag No description points to check ok correction action comment
611.SI100D01L41 Level switch check for looseness , cleaning , cables , cover
Level
611.SI100N01U41 transmitter check for looseness , cleaning , cables , cover
621.BK120 discharging check discharging spout with panel & all sensors & fans for
Spout cables, cleaning, earthing, damage & looseness
check blower room for cleaning, lighting, ventilation
6122.BL300 Blower
check blower for cleaning, noise, vibration
612.BL300D01P41 pressure.Tr
check transmitter for cleaning, damage, cable, looseness,
ansmitter display & hose connection
check transmitter for cleaning, damage, cable, looseness,
612AR315D01P41 pressure.Tr display & hose connection
ansmitter
612.FG601 Flow gate check the flow gate with positioner for cable , cleaning,
earthing, the diplay if OK, looseness& the coil
612.FG611 Flow gate check the flow gate with positioner for cable , cleaning,
earthing, the diplay if OK, looseness& the coil
600A1 20
Transport between cement silos to Packing plant
Tag No description points to check ok correction action comment
612.FG621 Flow gate check the flow gate with positioner for cable , cleaning,
earthing, the diplay if OK, looseness& the coil
612.FG631 Flow gate check the flow gate with positioner for cable , cleaning,
earthing, the diplay if OK, looseness& the coil
612.FG641 Flow gate check the flow gate with positioner for cable , cleaning,
earthing, the diplay if OK, looseness& the coil
612.SI100Y12/13/14/ Silo check all solenoid valves for cables, damage,
15/16/17/18/19 Aeration looseness,cleaning
discharging check discharging spout with panel & all sensors & fans for
622.BK120 Spout cables, cleaning, earthing, damage & looseness
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
622.FN191 fan /
622.AS190 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
622.FN181 fan /
622.AS180 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
622.FN201 fan /
622.AS200 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
622.FN211 fan /
622.AS210 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
622.FN251 fan /
622.AS250 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
622.FN351 fan /
622.AS350 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
600A1 21
Transport between cement silos to Packing plant
Tag No description points to check ok correction action comment
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
621.FN251 fan /
621.AS250 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
check motor for earthing connection
air slide check motor for heating , vibration , noise , cable , cleaning
621.FN351 fan /
621.AS350 check LCP for cable , damage , cleaning
check filter of fan for cleaning, available
check motor for earthing connection
621.FN507 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
621.BF505 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
Rotary air
621.RF506 check motor for heating , vibration , noise , cable , cleaning
lock
check LCP for cable , damage , cleaning
check motor for earthing connection
621.FN552 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
621.BF550 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
621.RF551 Rotary air
lock check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check motor for earthing connection
622.FN507 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
622.BF505 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
600A1 22
Transport between cement silos to Packing plant
Tag No description points to check ok correction action comment
check motor for earthing connection
Rotary air
622.RF506 lock check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check motor for earthing connection
622.FN552 Fan check motor for heating , vibration , noise , cable , cleaning
check LCP for cable , damage , cleaning
check solenoid valves for damage , cleaning & looseness
check control panel for earthing , damage , alarm , cleaning
622.BF550 Bag filter
check all cables on bag filter for damage & cable gland
check differential pressure hoses
check motor for earthing connection
Rotary air
622.RF551 check motor for heating , vibration , noise , cable , cleaning
lock
check LCP for cable , damage , cleaning
Earthing check earthing bar & earthing points for
System fixed,connection,damage
lighting & check for damage, cleaning, cable, in case some rechargeable
Sockets check if it is charging
600A1 23
Transport between cement silos to Packing plant
600A2 24
Transport between cement silos to Packing plant
600A2 25
Transport between cement silos to Packing plant
600A2 26
Transport between cement silos to Packing plant
6222BE380D01S41 Motion check both motion detectors with junction box for cleaning ,
Detector cables , looseness
Earthing check earthing bar & earthing points for
System fixed,connection,damage
lighting & check for damage, cleaning, cable, in case some rechargeable
Sockets check if it is charging
600A2 27